The following table gives a
detailed description of the type of information prompted for by the data entry
fields. Elements provided to guide the user include predefined picklist phrases, freetext
templates and context-sensitive help texts. In addition, technical elements are
provided, i.e. field and data types, explanations for use in Data Element
Dictionary (DED) and the xml schema. The conventions used are explained in part
'Introduction
and Format of OECD Harmonised Templates'.
|
Field description [Field label] |
|
Remarks, Picklist, Freetext
template |
Help text |
Explanation for use in Data Element Dictionary (DED) |
XML Schema |
|
|
|
ADMINISTRATIVE
DATA |
|
REMARKS: Under
this main heading, fields are subsumed for identifying the purpose of the record
(e.g., 'key study'), the type of result (e.g.,
'experimental study'), data waiving indication (if any), reliability
indication, and flags for indicating the regulatory purpose envisaged and/or
any confidentiality restrictions. This kind of data characterise
the relevance of a study summary and may therefore be displayed on top of
each template. For detailed guidance, refer to Administrative data. |
|
|
|
|
SE09.06.00.0215 |
DATA SOURCE [Data
source] |
|
|
|
Main heading under which generic 'Data source' fields are subsumed. |
|
|
SE09.06.00.0219 |
[Reference] |
|
|
Indicate the bibliographic reference of the study report or publication the study summary is based on. Always enter the primary reference in the first block of fields (i.e. Sort no. = 1), if there are more than one reference to be cited. Copy this block of fields for specifying any other references related to this record (e.g. report of a preliminary study or other documentation). If results of a study report have been published, indicate the full citation of that publication(s) in addition to the reference of the original study. |
Heading of field block 'Reference' |
|
|
SE09.06.00.0220 |
Reference type [Reference
type] |
|
Picklist Values: study
report || other company data || publication || review article or handbook ||
secondary source || grey literature || other: |
Indicate the type of reference, e.g. 'Study report' or 'Publication'. Select 'Other company data' to characterise any unpublished information from a company other than a study report. Select 'Grey literature' for any other unpublished information or 'other:' and specify. |
Indicator specifying the type of reference, e.g. 'Study report' or 'Publication'. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:REFERENCE> <i5:set> <i5:PHRASEOTHER_REFERENCE_TYPE> <i5:REFERENCE_TYPE> |
|
SE09.06.00.0221 |
Reference type [no
label] |
|
|
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:REFERENCE> <i5:set> <i5:PHRASEOTHER_REFERENCE_TYPE> <i5:REFERENCE_TYPE_TXT> |
|
|
SE09.06.00.0230 |
Author(s) (or transferred reference) [Author] |
|
|
For ease of sorting and searchability use following convention: Surname, Initial (Example 1: White D, Ruehl KJ, Borman SA & Little J. Example 2: Hartley M & Murray W (avoid unnecessary full-stops, commas)). If no individuals are cited as authors, enter name of company or organisation or 'Anon.' as appropriate. Note that the complete bibliographic reference may appear in this field after migration of unstructured data from existing databases. |
Name(s) of author(s) of the study report or publication. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:REFERENCE> <i5:set> <i5:REFERENCE_AUTHOR> <i5:REFERENCE_AUTHOR> |
|
SE09.06.00.0240 |
Year [Year] |
|
|
Enter year of study report or publication. For a study report this field should be completed to include it in any searches, regardless of whether the complete date is given in field 'Report date'. |
Year of the study report or publication. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:REFERENCE> <i5:set> <i5:REFERENCE_YEAR> <i5:REFERENCE_YEAR> |
|
SE09.06.00.0250 |
Title [Title] |
|
|
Include the title of the report. For publications, include the title of the article of a journal or article/chapter of a book (e.g. handbook). |
Title of a study report or title of published article of journal or book (e.g. handbook). |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:REFERENCE> <i5:set> <i5:REFERENCE_TITLE> <i5:REFERENCE_TITLE> |
|
SE09.06.00.0260 |
Bibliographic source [Bibliographic
source] |
|
|
Not relevant for any study report. For publications or any other literature source (grey literature) specify the following type of information: (i) Title of scientific journal or book (e.g. if handbook); (ii) Volume of journal; (iii) Editor, publisher, place of publication for books or articles in books; (iv) Pagination. Example 1 (journal): J. Agric. Food Chem. 38: 215-227 Example 2 (handbook): In: Lyman WJ (ed.) Handbook of chemical property estimation methods. Environmental behavior of organic compounds. McGraw-Hill Book Company 15.1-15.34, New York. |
Bibliographic source of the study report or publication. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:REFERENCE> <i5:set> <i5:REFERENCE_SOURCE> <i5:REFERENCE_SOURCE> |
|
SE09.06.00.0270 |
Testing laboratory [Testing
laboratory] |
|
|
Either manually enter the name of the testing laboratory or select it from the picklist. In either case, editing is possible. |
Name of the testing laboratory. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:REFERENCE> <i5:set> <i5:REFERENCE_TESTLAB> <i5:REFERENCE_TESTLAB> |
|
SE09.06.00.0280 |
Report no. [Report
no.] |
|
|
Specify the report number allocated by the testing laboratory. Note that any company-specific study number should be included in the respective field. |
Report number allocated by the testing laboratory. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:REFERENCE> <i5:set> <i5:REFERENCE_REPORT_NO> <i5:REFERENCE_REPORT_NO> |
|
SE09.06.00.0290 |
Owner company [Owner
company] |
|
|
Either manually enter the identity of the company who owns the data or select it from the picklist. In either case, editing is possible. |
Identity of the sponsor company who owns the study report. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:REFERENCE> <i5:set> <i5:REFERENCE_COMPANY_ID> <i5:REFERENCE_COMPANY_ID> |
|
SE09.06.00.0300 |
Company study no. [Company
study no.] |
|
|
Specify any company study no. if there is such a number and if it is different from the report no. of the testing laboratory. Otherwise leave field empty. |
Company-specific study number. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:REFERENCE> <i5:set> <i5:REFERENCE_COMPANY_STUDY_NO> <i5:REFERENCE_COMPANY_STUDY_NO> |
|
SE09.06.00.0310 |
Report date [Report
date] |
|
|
Specify the complete date of the study report, e.g. '2005-05-12' for 12 May 2005. Note that subfield 'Year' should be completed in any case for sorting and searching purposes. |
Complete date of the study report. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:REFERENCE> <i5:set> <i5:REFERENCE_REPORT_DATE> <i5:REFERENCE_REPORT_DATE> |
|
SE09.06.00.0320 |
Data access [Data
access] |
|
Picklist Values: data
submitter is data owner || data submitter has Letter of Access || data no
longer protected || data published || not applicable || other: |
Select appropriate indication for data access. Enter 'Not applicable' if the summary consists of information that is commonly accessible such as guidance on safe use. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:DATA_ACCESS> <i5:set> <i5:PHRASEOTHER_LIST_POP> <i5:LIST_POP> |
|
|
SE09.06.00.0321 |
Data access [no
label] |
|
|
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:DATA_ACCESS> <i5:set> <i5:PHRASEOTHER_LIST_POP> <i5:LIST_POP_TXT> |
|
|
SE09.06.00.0330 |
Data protection claimed [Data
protection claimed] |
|
Picklist Values: yes
|| yes, but willing to share || yes, but not willing to share |
Indicate as appropriate. Note: 'yes' should be selected only if 'Data submitter is data owner' or 'Data submitter has Letter of Access'. Options 'yes, but willing to share' or 'yes, but not willing to share' may be relevant for specific regulatory programmes where the submitter is requested to indicate whether he is willing to share studies (e.g. with vertebrates). In the supplementary remarks field, include an explanation as appropriate, i.e. justification for denial of sharing the corresponding study or refer to a document attached that provides justification (e.g. 'for justification see attached document X') |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:DATA_PROT_CLAIM> <i5:set> <i5:PHRASEOTHER_LIST_POP_FIX> <i5:LIST_POP_FIX> |
|
|
SE09.06.00.0331 |
Data protection claimed [no
label] |
|
|
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:DATA_PROT_CLAIM> <i5:set> <i5:PHRASEOTHER_LIST_POP_FIX> <i5:LIST_POP_FIX_TXT> |
|
|
SE09.06.00.0340 |
Cross-reference to same study [Cross-reference
to same study] |
|
|
A cross-reference can be included to indicate that the same study is recorded in another record. Indicate the respective chapter and record ID and enter relevant explanatory text. This may be useful if specific endpoints of a given study are described in another chapter (e.g. results on reproduction toxicity in case of a combined repeated dose / reproduction toxicity study) or if more than one experiment is described by the same study report, but included in separate records. Check with the relevant guidance document whether all the methodology details must be repeated or whether a cross-reference to the same study in another chapter may suffice. Note that any such cross-reference may become useless if a record is either printed or exchanged on its own. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:CROSSREF_SAMESTUDY> <i5:set> <i5:TEXT_BELOW> <i5:TEXT_BELOW> |
|
|
SE09.06.00.0345 |
MATERIALS AND METHODS [Materials
and methods] |
|
|
|
Main heading under which generic 'Materials and methods' fields are subsumed. |
|
|
SE09.06.00.0350 |
Study type [Study
type] |
|
Picklist Values: Leaching
|| other: |
Indicate the appropriate study type. |
Indicator specifying study type |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:STUDY_TYPE> <i5:set> <i5:PHRASEOTHER_LIST_POP> <i5:LIST_POP> |
|
SE09.06.00.0351 |
Study type [no
label] |
|
|
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:STUDY_TYPE> <i5:set> <i5:PHRASEOTHER_LIST_POP> <i5:LIST_POP_TXT> |
|
|
SE09.06.00.0360 |
Company Study No. [Company
Study No.] |
|
|
Specify any company study number if there is such a number and if it is different from the report number of the testing laboratory. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:COMPANY_STUDY_NO> <i5:set> <i5:TEXT_BELOW> <i5:TEXT_BELOW> |
|
|
SE09.06.00.0370 |
Report date [Report
date] |
|
|
Specify the date of the study report. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:REPORT_DATE> <i5:set> <i5:TEXT_SHORT_BELOW> <i5:TEXT_SHORT_BELOW> |
|
|
SE09.06.00.0380 |
Test water [Test
water] |
|
Picklist Values: freshwater
|| seawater |
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:TEST_WATER> <i5:set> <i5:LIST_BELOW_SEL> <i5:LIST_BELOW_SEL> |
|
|
SE09.06.00.0389 |
Test guideline [Test
guideline] |
|
|
Indicate according to which test guideline the study was conducted. If no test guideline was explicitly followed, but the methodology used is equivalent or similar to a specific guideline, you can indicate so in the 'Qualifier' subfield preceding the field 'Guideline'. Copy this block of fields for specifying more than one guideline (e.g. US EPA in addition to OECD guideline). |
Heading of field block 'Guideline' |
|
|
SE09.06.00.0390 |
Qualifier [Qualifier] |
|
Picklist Values: according
to || equivalent or similar to || no guideline followed || no guideline
available || no guideline required |
Select appropriate qualifier, i.e. - 'according to' (if a given test guideline was followed); - 'equivalent or similar to' (if no test guideline was explicitly followed, but the methodology is equivalent or similar to a specific guideline); - 'no guideline followed' (if none of above qualifiers apply. If so, fill in field 'Principles of method if other than guideline'); - 'no guideline available/required' (if applicable; fill in field 'Principles of method if other than guideline'). |
An indicator signifying how strict the guideline given in the subsequent field 'Guideline' was followed or whether no guideline was used or available/required. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:GUIDELINE> <i5:set> <i5:QUALIFIER> <i5:QUALIFIER> |
|
SE09.06.00.0400 |
Guideline [Guideline] |
|
Picklist Values: OECD
Guideline 313 (Estimation of Emissions from Preservative - Treated Wood to
the Environment: Laboratory Method for wooden commodities that are not
Covered and are in contact with Fresh Water or Seawater) || other guideline: |
Select the applicable test guideline, e.g. 'OECD Guideline xxx'. If the test guideline used is not listed, choose 'other guideline:' and specify the test guideline in the related text field. In this text field, you can also enter any remarks as applicable, particularly: - To include any other title of the test guideline draft used, a subtitle, another version or update number and the year of update (For instance, different titles and/or numbers may exist for a given EU test guideline.); - To indicate if a the study was performed prior to the adoption of the test guideline specified; - To indicate if the methodology used was based on an extension of the test guideline specified. |
An indicator signifying how strict the guideline given in the subsequent field 'Guideline' was followed or whether no guideline was used or available/required. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:GUIDELINE> <i5:set> <i5:PHRASEOTHER_GUIDELINE> <i5:GUIDELINE> |
|
SE09.06.00.0401 |
Guideline [no
label] |
|
|
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:GUIDELINE> <i5:set> <i5:PHRASEOTHER_GUIDELINE> <i5:GUIDELINE_TXT> |
|
|
SE09.06.00.0420 |
Deviations from guideline [Deviations] |
|
Picklist Values: yes
|| no || no data || not applicable |
For robust study summaries or as requested by the regulatory programme, indicate if there are any deviations from the test guideline specified. If 'yes' is selected, only briefly state relevant deviations in the supplementary remarks field (e.g. 'other species used'); details should be described in the respective fields of the section MATERIALS AND METHODS. |
Indication that a study contains deviations from the standard test protocol. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:GUIDELINE> <i5:set> <i5:PHRASEOTHER_DEVIATION> <i5:DEVIATION> |
|
SE09.06.00.0421 |
Deviations from guideline [no
label] |
|
|
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:GUIDELINE> <i5:set> <i5:PHRASEOTHER_DEVIATION> <i5:DEVIATION_TXT> |
|
|
SE09.06.00.0430 |
Principles of method if other than guideline [Principles
of method if other than guideline] |
|
|
If no guideline was followed, include a description of the principles of the test protocol or estimated method used in the study. Details should be entered in appropriate distinct fields of section MATERIALS AND METHODS if available. Also provide a justification for using this method if appropriate. If an estimation method was used (to be indicated in field 'Test result type') state the equation(s) and/or computer software or other methods applied to calculate the value(s). |
Description of the test protocol or estimated method used in the study, if other than a guideline, and justification for using this method if appropriate. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:METHOD_NOGUIDELINE> <i5:set> <i5:TEXTAREA_BELOW> <i5:TEXTAREA_BELOW> |
|
SE09.06.00.0440 |
GLP compliance [GLP
compliance] |
|
Picklist Values: yes
(incl. certificate) || yes || no || no data |
Indicate whether the study was conducted following Good Laboratory Practice or not. Select 'yes (incl. certificate)' if a GLP certificate of a test facility is available. Select 'yes' if a GLP compliance statement is available, but no information on a GLP certificate. You can give an explanation in the supplementary remarks field, e.g. for explaining why GLP was not complied with or for specifying which (national) GLP was followed. |
Indication whether a GLP certificate or compliance statement is available. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:GLP_COMPLIANCE_STATEMENT> <i5:set> <i5:PHRASEOTHER_LIST_SEL_FIX> <i5:LIST_SEL_FIX> |
|
SE09.06.00.0441 |
GLP compliance [no
label] |
|
|
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:GLP_COMPLIANCE_STATEMENT> <i5:set> <i5:PHRASEOTHER_LIST_SEL_FIX> <i5:LIST_SEL_FIX_TXT> |
|
|
SE09.06.00.0445 |
Test materials [Test
materials] |
|
|
|
Subheading of section 'Test materials' |
|
|
SE09.06.00.0450 |
Identity of test material same as for substance defined in section 1 (if not read across) [Identity
of test material same as for substance defined in section 1 (if not read
across)] |
|
Picklist Values: yes
|| no |
Indicate if the test material used in the study is equivalent to the submission substance identity. If 'yes' is selected, the corresponding identity is automatically entered in the subsequent block of fields 'Test material identity'. If 'no' is selected, identify the test material in the subsequent block of fields 'Test material identity'. In this case, also make sure that the information entered in field 'Study result type' is consistent, i.e. 'read-across from supporting substance (structural analogue or surrogate)'. NOTE: If a completed record is used for another submission, you may have to update both fields 'Study result type' and 'Test material equivalent to submission substance identity'. |
Indicator showing whether the test material used is equivalent to the submission substance identity. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:TESTMAT_INDICATOR> <i5:set> <i5:LIST_BELOW_SEL> <i5:LIST_BELOW_SEL> |
|
SE09.06.00.0459 |
Test material identity [Test
material identity] |
|
|
If the identity of the test material used for this study is not included in this block of fields automatically, indicate the identity for one or more appropriate identifiers, e.g. CAS number, CAS name, IUPAC name. Copy this block of fields as appropriate. If another than the submission substance identity was selected erroneously, go back to field 'Test material equivalent to submission substance identity' and select 'yes'. This will prompt automatic entry of the respective identifiers. |
Heading of field block 'Test material identity' |
|
|
SE09.06.00.0460 |
Identifier [Identifier] |
|
Picklist Values: CAS
name || CAS number || Common name || EC name || EC number || IUPAC name ||
TSCA name || other: |
Select an appropriate identifier from drop-down list, e.g. 'CAS number'. Use 'Other:' and specify, if identity according to a standard identifier is not known or if an additional chemical name or number is provided. |
Indicator specifying the type of chemical identifier, e.g. CAS name. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:TESTMAT> <i5:set> <i5:PHRASEOTHER_IDENTIFIER> <i5:IDENTIFIER> |
|
SE09.06.00.0461 |
Identifier [no
label] |
|
|
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:TESTMAT> <i5:set> <i5:PHRASEOTHER_IDENTIFIER> <i5:IDENTIFIER_TXT> |
|
|
SE09.06.00.0470 |
Identity [Identity] |
|
|
Select the corresponding substance identity from drop-down list or enter manually if the identity is not available from the list or if no list is provided for the type of identifier selected. |
Identity of the chemical substance used in the study or referred to in the record. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:TESTMAT> <i5:set> <i5:ID> <i5:ID> |
|
SE09.06.00.0475 |
Physical form [Test
material form] |
|
Picklist Values: aerosol
|| compact || crystalline || dispersion || fibre ||
filaments || flakes || liquified gas ||
nanomaterial || particulates || paste || pellets || powder || refrigerated liquid
|| suspension || viscous || other: || no data |
|
Form of the substance, i.e. powder, crystalline, compact, viscous, etc. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:TESTMAT_FORM> <i5:set> <i5:PHRASEOTHER_TESTMAT_FORM> <i5:TESTMAT_FORM> |
|
SE09.06.00.0476 |
Test material form [no
label] |
|
|
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:TESTMAT_FORM> <i5:set> <i5:PHRASEOTHER_TESTMAT_FORM> <i5:TESTMAT_FORM_TXT> |
|
|
SE09.06.00.0480 |
Details on test material [Details
on test material] |
|
Freetext Templates: - Name of test material (as cited in study report): - Molecular formula (if other than submission substance): - Molecular weight (if other than submission substance): - Smiles notation (if other than submission substance): - InChl (if other than submission substance): - Structural formula attached as image file (if other than submission substance): see Fig. - Substance type: - Physical state: - Analytical purity: - Impurities (identity and concentrations): - Composition of test material, percentage of components: - Isomers composition: - Purity test date: - Lot/batch No.: - Expiration date of the lot/batch: - Radiochemical purity (if radiolabelling): - Specific activity (if radiolabelling): - Locations of the label (if radiolabelling): - Expiration date of radiochemical substance (if radiolabelling): - Stability under test conditions: - Storage condition of test material: - Other: |
Use freetext template and delete/add elements as appropriate. Enter any details that could be relevant for evaluating this study summary or that are requested by the respective regulatory programme. Consult the programme-specific guidance (e.g. OECD HPVC, Pesticides NAFTA or EU REACH) thereof. Note that any information that can be claimed confidential should be included in the subsequent field 'Confidential details on test material'. Explanations: - Name of test material (as cited in study report): only if different from any other identifiers provided in the preceding fields. - Molecular formula (if other than submission substance): specify - Molecular weight (if other than submission substance): specify - Smiles notation (if other than submission substance): provide if available - InChl (if other than submission substance): provide if available - Structural formula attached as image file (if other than submission substance): see Fig.: only if different from submission substance. Indicate Fig. no. if a file is attached in field 'Attached document', e.g. state 'see Fig. 1'. - Substance type: indicate whether pure active substance, technical product, formulation or other. - Physical state: indicate 'gas', 'solid' or 'liquid' only if different from submission substance or if substance can occur in different physical states. - Analytical purity: specify in % - Impurities (identity and concentrations): specify - Composition of the test material, percentage of components: specify if applicable - Isomers composition: specify if applicable - Purity test date: provide if available - Lot/batch No.: provide if available - Expiration date of the lot/batch: provide if available - Radiochemical purity (if radiolabelling): specify if applicable - Specific activity (if radiolabelling): specify if applicable - Locations of the label (if radiolabelling): specify if applicable - Expiration date of radiochemical substance (if radiolabelling): specify if applicable - Storage condition of test substance: specify if applicable - Stability under test conditions: indicate if available |
Details on description and specification of the actual test material. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:TESTMAT_DETAILS> <i5:set> <i5:FREETEXT_BELOW> <i5:FREETEXT_BELOW> |
|
SE09.06.00.0490 |
Confidential details on test material [Confidential
details on test material] |
|
Freetext Templates: - Analytical purity: - Impurities (identity and concentrations): - Composition of test material, percentage of components: - Purity test date: - Lot/batch No.: - Expiration date of the lot/batch: - Isomers composition: - Other: |
Enter any confidential information on the test material in this separate field. Use freetext template and delete/add elements as appropriate. Enter any details that could be relevant for evaluating this study summary or that are requested by the respective regulatory programme. Consult the programme-specific guidance (e.g. OECD HPVC, Pesticides NAFTA or EU REACH) thereof. Explanations: - Analytical purity: specify in % - Impurities (identity and concentrations): specify - Composition of the test material, percentage of components: specify if applicable - Purity test date: provide if available - Lot/batch No.: provide if available - Expiration date of the lot/batch: provide if available - Isomers composition: specify if applicable |
Confidential details on the actual test material. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:TESTMAT_CONFIDENTIAL_DETAILS> <i5:set> <i5:FREETEXT_BELOW> <i5:FREETEXT_BELOW> |
|
SE09.06.00.0525 |
Wood Preservative [Wood
Preservative] |
|
|
|
|
|
|
SE09.06.00.0530 |
Supplier of the preservative (name) [Supplier
of the preservative (name)] |
|
|
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:SUPPLIER_PRESERV> <i5:set> <i5:TEXT_BELOW> <i5:TEXT_BELOW> |
|
|
SE09.06.00.0540 |
Type of formulation [Type
of formulation] |
|
Picklist Values: liquid
formulation || emulsion/micro-emulsion || solid formulation || granulate
material || rod/cartridge || pastes || bandages || foams || gas generating
product || other: |
Indicate the type of formulation for the product. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:TYPE_FORMULATION> <i5:set> <i5:PHRASEOTHER_LIST_POP> <i5:LIST_POP> |
|
|
SE09.06.00.0541 |
Type of formulation [no
label] |
|
|
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:TYPE_FORMULATION> <i5:set> <i5:PHRASEOTHER_LIST_POP> <i5:LIST_POP_TXT> |
|
|
SE09.06.00.0550 |
Preservative (specific and unique name or code) [Preservative
(specific and unique name or code)] |
|
Picklist Values: Oil
Borne: Creosote || Oil Borne: Creosote solutions || Oil Borne: Creosote -
petroleum || Oil Borne: Pentachlorophenol (PCP) Type A || Oil Borne: Pentachlorphenol (PCP) Type E || Oil Borne: Copper Napthenate || Oil Borne: Oxine
Copper (copper-8-quinolinolate) || Oil Borne: Propiconazole
|| Oil Borne: Tebuconazole || Oil Borne: Chloropyiphos || Waterborne: Acid Copper chromate (ACC)
or didecyldimethylammonium-chloride (DDAC) ||
Waterborne: didecyldimethylammonium
carbonate/bicarbonate (Carboquat) || Waterborne:
Alkaline Copper Quat Type B (ACQ-B) || Waterborne:
Alkaline Copper Quat Type D (ACQ-D) || Waterborne:
Alkyl Ammonia Compound (ACC) and Inorganic Boron || Waterborne: Ammoniacal Copper Citrate (CC) || Waterborne: Ammoniacle Copper Zinc Arsenate (ACZA) or Ammoniacal Copper Zinc || Waterborne: Arsenate (ACA) ||
Waterborne: Borate Preservatives || Waterborne: Copper Azol-Type
A (CBA-A) || Waterborne: Copper Azole Type B (CA-B)
(Wolman E) || Waterborne: Copper Bis(Dimethyldithiocarbamate) (CDDC) || Waterborne: Chromated Copper Arsenate Type A (CCA-A) (Greensalt) || Waterborne: Chromated
copper Arsenate Type B (CCA-B)(K-33) || Waterborne: Chromated
Copper Arsenate Type C (CCA-C) (Wolman) || Waterborne: 4,5,
Dichloro-n-octyl-4-isothiazolin-3-one (RH-287) (Kathon)
|| other: |
Indicate the type of wood preservative used, and select 'other' to characterize any unlisted preservative. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:PRESERVATIVE> <i5:set> <i5:PHRASEOTHER_LIST_POP> <i5:LIST_POP> |
|
|
SE09.06.00.0551 |
Preservative (specific and unique name or code) [no
label] |
|
|
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:PRESERVATIVE> <i5:set> <i5:PHRASEOTHER_LIST_POP> <i5:LIST_POP_TXT> |
|
|
SE09.06.00.0560 |
Active Ingredient(s) (trade or common name) [Active
Ingredient(s) (trade or common name)] |
|
Picklist Values: arsenic
|| arsenic acid || arsenic pentaoxide || boric acid
|| chromium || chromium trioxide || citric acid || copper carbonate || copper
hydroxide || copper oxide || copper sulfate || creosote || pyroarsenate || sodium arsenate || sodium borate ||
sodium pentaborate || sodium cotoborate
|| sodium tetraborate || zinc || zinc oxide || 4,5,
Dichloro-n-octyl-4-isothiazolin-3-one || other: |
Indicate the type of wood preservative used, and select 'other' to characterize any unlisted preservative. Also, indicate one or more of the appropriate identifiers (e.g. CAS number, CAS name, IUPAC name, EC name, EC, number, TSCA name). |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:ACTIVE_INGREDIENTS> <i5:set> <i5:PHRASEOTHER_LIST_POP> <i5:LIST_POP> |
|
|
SE09.06.00.0561 |
Active Ingredient(s) (trade or common name) [no
label] |
|
|
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:ACTIVE_INGREDIENTS> <i5:set> <i5:PHRASEOTHER_LIST_POP> <i5:LIST_POP_TXT> |
|
|
SE09.06.00.0580 |
Composition (in % m/m) [Composition
(in % m/m)] |
|
|
When multiple active constituents are present in the timber treatment formulation, the % m/m composition of each of the active constituents is to be given along with the chemical form in which the active constituent is measured (e.g.; if cuprous oxide is used, the % of copper and oxide should be expressed individually). |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:COMPOSITION> <i5:set> <i5:TEXT_BELOW> <i5:TEXT_BELOW> |
|
|
SE09.06.00.0585 |
Coformulants [Coformulants] |
|
|
Give a generic description of the coformulants (e.g. co-solvent, resine, etc.) |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:COFORMULANTS> <i5:set> <i5:TEXTAREA_BELOW> <i5:TEXTAREA_BELOW> |
|
|
SE09.06.00.0590 |
Retention or loading specified for tested wood [Retention
or loading specified for tested wood] |
|
Picklist Values: label
retention rates || actual test retention rate |
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:RETENTION> <i5:set> <i5:LIST_BELOW_SEL> <i5:LIST_BELOW_SEL> |
|
|
SE09.06.00.0595 |
Application [Application] |
|
|
|
|
|
|
SE09.06.00.0600 |
Application method [Application
method] |
|
Picklist Values: penetration
process || vacuum pressure//penetration process || double vacuum
pressure//superficial treatment || dipping//superficial treatment ||
spraying//superficial treatment || brushing//industrial treatment |
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:APPLICATION_METHOD> <i5:set> <i5:LIST_BELOW_SEL> <i5:LIST_BELOW_SEL> |
|
|
SE09.06.00.0610 |
Treatment Facility [Treatment
Facility] |
|
|
Manually insert the name of the treatment facility with contact information. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:TREAT_FACILITY> <i5:set> <i5:TEXT_BELOW> <i5:TEXT_BELOW> |
|
|
SE09.06.00.0620 |
Registrant [Registrant] |
|
|
Manually insert the name of the registrant with contact information. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:REGISTRANT> <i5:set> <i5:TEXT_BELOW> <i5:TEXT_BELOW> |
|
|
SE09.06.00.0630 |
Details of method (treatment schedule) [Details
of method (treatment schedule)] |
|
|
Include a title of the manufacturer/label directions, include a title of the report that documents the treatment process. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:DETAIL_METHOD> <i5:set> <i5:TEXT_BELOW> <i5:TEXT_BELOW> |
|
|
SE09.06.00.0640 |
Date of application [Date
of application] |
|
|
Identify how much time has elapsed between date of application and start of immersion. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:APPLICATION_DATE> <i5:set> <i5:TEXT_BELOW> <i5:TEXT_BELOW> |
|
|
SE09.06.00.0660 |
Formula used to calculate the retention [Formula
used to calculate the retention] |
|
|
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:FORMULA_RETENTION> <i5:set> <i5:TEXT_BELOW> <i5:TEXT_BELOW> |
|
|
SE09.06.00.0670 |
Conditioning procedure (type, conditions, duration) [Conditioning
procedure (type, conditions, duration)] |
|
|
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:COND_PROC> <i5:set> <i5:TEXT_BELOW> <i5:TEXT_BELOW> |
|
|
SE09.06.00.0700 |
End sealant (specification and number of times applied) [End
sealant (specification and number of times applied)] |
|
|
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:END_SEALANT> <i5:set> <i5:TEXT_BELOW> <i5:TEXT_BELOW> |
|
|
SE09.06.00.0720 |
Subsequent treatment (paint supplier, paint type, characteristics and loading of paint) [Subsequent
treatment (paint supplier, paint type, characteristics and loading of paint)] |
|
|
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:SUBS_TREAT> <i5:set> <i5:TEXT_BELOW> <i5:TEXT_BELOW> |
|
|
SE09.06.00.0745 |
Test Specimens [Test
Specimens] |
|
|
|
|
|
|
SE09.06.00.0749 |
[Test
specimens] |
|
|
|
|
|
|
SE09.06.00.0750 |
Wood species [Wood
species] |
|
Picklist Values: Pinus sylvestris L. || Pinus resinosa Ait. || Pinus spp
|| other: |
Give the species name if timbers other than the Pinus species from the picklist are used. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:TEST_SPECIMENS> <i5:set> <i5:PHRASEOTHER_WS_LIST_POP> <i5:WS_LIST_POP> |
|
|
SE09.06.00.0751 |
Wood species [no
label] |
|
|
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:TEST_SPECIMENS> <i5:set> <i5:PHRASEOTHER_WS_LIST_POP> <i5:WS_LIST_POP_TXT> |
|
|
SE09.06.00.0760 |
Source of the wood [Source
of the wood] |
|
|
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:TEST_SPECIMENS> <i5:set> <i5:SW_TEXT_BELOW> <i5:SW_TEXT_BELOW> |
|
|
SE09.06.00.0770 |
Density of the wood [Density
of the wood] |
|
Picklist Values: >
|| >= || ca. |
Give the density of the tested wood |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:TEST_SPECIMENS> <i5:set> <i5:PRECISION_DENSITY_LOQUALIFIER> <i5:DENSITY_LOQUALIFIER> |
|
|
SE09.06.00.0771 |
Density of the wood [no
label] |
|
|
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:TEST_SPECIMENS> <i5:set> <i5:PRECISION_DENSITY_LOQUALIFIER> <i5:DENSITY_LOVALUE> |
|
|
SE09.06.00.0772 |
Density of the wood [no
label] |
|
Picklist Values: <
|| <= || ca. |
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:TEST_SPECIMENS> <i5:set> <i5:PRECISION_DENSITY_LOQUALIFIER> <i5:DENSITY_UPQUALIFIER> |
|
|
SE09.06.00.0773 |
Density of the wood [no
label] |
|
|
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:TEST_SPECIMENS> <i5:set> <i5:PRECISION_DENSITY_LOQUALIFIER> <i5:DENSITY_UPVALUE> |
|
|
SE09.06.00.0774 |
Density of the wood Unit [Density
of the wood Unit] |
|
Picklist Values: kg/m³ |
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:TEST_SPECIMENS> <i5:set> <i5:PRECISION_DENSITY_LOQUALIFIER> <i5:DENSITY_UNIT> |
|
|
SE09.06.00.0775 |
Growth rate (number of annual rings per 10 mm) [Growth
rate (number of annual rings per 10 mm)] |
|
Picklist Values: >
|| >= || ca. |
Give the number of annual rings per 10 mm of wood as an indicator of the tree growth rate |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:TEST_SPECIMENS> <i5:set> <i5:PRECISION_GROWTH_RATE_LOQUALIFIER> <i5:GROWTH_RATE_LOQUALIFIER> |
|
|
SE09.06.00.0776 |
Growth rate (number of annual rings per 10 mm) [no
label] |
|
|
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:TEST_SPECIMENS> <i5:set> <i5:PRECISION_GROWTH_RATE_LOQUALIFIER> <i5:GROWTH_RATE_LOVALUE> |
|
|
SE09.06.00.0777 |
Growth rate (number of annual rings per 10 mm) [no
label] |
|
Picklist Values: <
|| <= || ca. |
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:TEST_SPECIMENS> <i5:set> <i5:PRECISION_GROWTH_RATE_LOQUALIFIER> <i5:GROWTH_RATE_UPQUALIFIER> |
|
|
SE09.06.00.0778 |
Growth rate (number of annual rings per 10 mm) [no
label] |
|
|
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:TEST_SPECIMENS> <i5:set> <i5:PRECISION_GROWTH_RATE_LOQUALIFIER> <i5:GROWTH_RATE_UPVALUE> |
|
|
SE09.06.00.0780 |
Dimensions of the pieces of wood (in mm) [x] |
|
|
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:TEST_SPECIMENS> <i5:set> <i5:DIMENSION1> <i5:DIMENSION1> |
|
|
SE09.06.00.0790 |
Dimensions of the pieces of wood (in mm) [y] |
|
|
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:TEST_SPECIMENS> <i5:set> <i5:DIMENSION2> <i5:DIMENSION2> |
|
|
SE09.06.00.0800 |
Dimensions of the pieces of wood (in mm) [z] |
|
|
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:TEST_SPECIMENS> <i5:set> <i5:DIMENSION3> <i5:DIMENSION3> |
|
|
SE09.06.00.0820 |
Moisture content (%) [Moisture
content (%)] |
|
|
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:TEST_SPECIMENS> <i5:set> <i5:MC_TEXT_BELOW> <i5:MC_TEXT_BELOW> |
|
|
SE09.06.00.0829 |
[Water
samples] |
|
|
|
|
|
|
SE09.06.00.0830 |
Mean pH of water samples [Mean
pH of water samples] |
|
|
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:WATER_SAMPLES> <i5:set> <i5:PH> <i5:PH> |
|
|
SE09.06.00.0831 |
Mean temperature of water samples [Mean
temperature of water samples] |
|
|
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:WATER_SAMPLES> <i5:set> <i5:MEAN_TEMP> <i5:MEAN_TEMP> |
|
|
SE09.06.00.0832 |
Temperature of water samples Unit [Temperature
of water samples Unit] |
|
Picklist Values: °C
|| K || °F |
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:WATER_SAMPLES> <i5:set> <i5:TEMP_UNIT> <i5:TEMP_UNIT> |
|
|
SE09.06.00.0839 |
[Loading
conditions] |
|
|
|
|
|
|
SE09.06.00.0840 |
Ratio of wood weight per water volume in the immersion container [Ratio
of wood weight per water volume in the immersion container] |
|
|
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:LOADING_CONDITIONS> <i5:set> <i5:WOOD_WEIGHT_PER_WATER_VOLUME> <i5:WOOD_WEIGHT_PER_WATER_VOLUME> |
|
|
SE09.06.00.0841 |
Ratio of wood weight per water volume Unit [Ratio
of wood weight per water volume Unit] |
|
Picklist Values: kg/m³ |
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:LOADING_CONDITIONS> <i5:set> <i5:WOOD_WEIGHT_PER_WATER_VOLUME_UNIT> <i5:WOOD_WEIGHT_PER_WATER_VOLUME_UNIT> |
|
|
SE09.06.00.0842 |
Ratio of wood surface area to water volume [Ratio
of wood surface area to water volume] |
|
|
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:LOADING_CONDITIONS> <i5:set> <i5:WOOD_SURFACE_PER_WATER_VOLUME> <i5:WOOD_SURFACE_PER_WATER_VOLUME> |
|
|
SE09.06.00.0843 |
Ratio of wood surface area to water volume Unit [Ratio
of wood surface area to water volume Unit] |
|
Picklist Values: m�/m� |
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:LOADING_CONDITIONS> <i5:set> <i5:WOOD_SURFACE_PER_WATER_VOLUME_UNIT> <i5:WOOD_SURFACE_PER_WATER_VOLUME_UNIT> |
|
|
SE09.06.00.0845 |
Any other information on materials and methods incl. tables [Any
other information on materials and methods incl. tables] |
|
|
In this field, you can enter any information on materials and methods, for which no distinct field is available, or transfer free text from other databases. You can also open a rich text editor and create formatted text and tables or insert and edit any excerpt from a word processing or spreadsheet document, provided it was converted to the HTML format. Note: One rich text editor field each is provided for the MATERIALS AND METHODS and RESULTS section. In addition the fields 'Overall remarks' and 'Executive summary' allow rich text entry. |
Rich text editor field for creating formatted text and tables or inserting and editing any excerpt from a word processing or spreadsheet document, provided it was converted to the HTML format. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:REM_ME_TC> <i5:set> <i5:RICHTEXT_BELOW> <i5:RICHTEXT_BELOW> |
|
SE09.06.00.0850 |
RESULTS AND DISCUSSION [Results
and discussions] |
|
|
|
Main heading under which generic 'Results and discussion' fields are subsumed. |
|
|
SE09.06.00.1009 |
Retention [Retention] |
|
|
|
|
|
|
SE09.06.00.1010 |
Replicate Number [Replicate
Number] |
|
|
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:RETENTION_BLOCK> <i5:set> <i5:REPLICATE_NUMBER> <i5:REPLICATE_NUMBER> |
|
|
SE09.06.00.1011 |
Retention [Retention] |
|
Picklist Values: >
|| >= || ca. |
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:RETENTION_BLOCK> <i5:set> <i5:PRECISION_RETENTION_LOQUALIFIER> <i5:RETENTION_LOQUALIFIER> |
|
|
SE09.06.00.1012 |
Retention [no
label] |
|
|
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:RETENTION_BLOCK> <i5:set> <i5:PRECISION_RETENTION_LOQUALIFIER> <i5:RETENTION_LOVALUE> |
|
|
SE09.06.00.1013 |
Retention [no
label] |
|
Picklist Values: <
|| <= || ca. |
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:RETENTION_BLOCK> <i5:set> <i5:PRECISION_RETENTION_LOQUALIFIER> <i5:RETENTION_UPQUALIFIER> |
|
|
SE09.06.00.1014 |
Retention [no
label] |
|
|
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:RETENTION_BLOCK> <i5:set> <i5:PRECISION_RETENTION_LOQUALIFIER> <i5:RETENTION_UPVALUE> |
|
|
SE09.06.00.1015 |
Retention Unit [Retention
Unit] |
|
Picklist Values: kg/m³
|| L/m� |
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:RETENTION_BLOCK> <i5:set> <i5:PRECISION_RETENTION_LOQUALIFIER> <i5:RETENTION_UNIT> |
|
|
SE09.06.00.1016 |
Retention standard deviation [Retention
standard deviation] |
|
|
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:RETENTION_BLOCK> <i5:set> <i5:RETENTION_STDDEV> <i5:RETENTION_STDDEV> |
|
|
SE09.06.00.1017 |
Remarks [Remarks] |
|
|
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:RETENTION_BLOCK> <i5:set> <i5:RETENTION_REMARKS> <i5:RETENTION_REMARKS> |
|
|
SE09.06.00.1019 |
Leaching [Leaching] |
|
|
|
|
|
|
SE09.06.00.1020 |
Time [Time] |
|
|
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:LEACHING> <i5:set> <i5:TIME> <i5:TIME> |
|
|
SE09.06.00.1021 |
Time Unit [Time
Unit] |
|
Picklist Values: s
|| min || h || d || wk || mo || yr |
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:LEACHING> <i5:set> <i5:TIME_UNIT> <i5:TIME_UNIT> |
|
|
SE09.06.00.1022 |
Active ingredient [Active
ingredient] |
|
|
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:LEACHING> <i5:set> <i5:ACTIVE_INGREDIENT> <i5:ACTIVE_INGREDIENT> |
|
|
SE09.06.00.1023 |
Type of specimen [Type
of specimen] |
|
Picklist Values: treated
|| untreated |
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:LEACHING> <i5:set> <i5:TYPE_OF_SPECIMEN> <i5:TYPE_OF_SPECIMEN> |
|
|
SE09.06.00.1024 |
Specimen number [Specimen
number] |
|
|
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:LEACHING> <i5:set> <i5:SPECIMEN_NUMBER> <i5:SPECIMEN_NUMBER> |
|
|
SE09.06.00.1025 |
Emission rate [Emission
rate] |
|
Picklist Values: >
|| >= || ca. |
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:LEACHING> <i5:set> <i5:PRECISION_EMISSION_RATE_LOQUALIFIER> <i5:EMISSION_RATE_LOQUALIFIER> |
|
|
SE09.06.00.1026 |
Emission rate [no
label] |
|
|
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:LEACHING> <i5:set> <i5:PRECISION_EMISSION_RATE_LOQUALIFIER> <i5:EMISSION_RATE_LOVALUE> |
|
|
SE09.06.00.1027 |
Emission rate [no
label] |
|
Picklist Values: <
|| <= || ca. |
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:LEACHING> <i5:set> <i5:PRECISION_EMISSION_RATE_LOQUALIFIER> <i5:EMISSION_RATE_UPQUALIFIER> |
|
|
SE09.06.00.1028 |
Emission rate [no
label] |
|
|
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:LEACHING> <i5:set> <i5:PRECISION_EMISSION_RATE_LOQUALIFIER> <i5:EMISSION_RATE_UPVALUE> |
|
|
SE09.06.00.1029 |
Emission rate unit [Emission
rate unit] |
|
Picklist Values: mg/m�/d |
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:LEACHING> <i5:set> <i5:PRECISION_EMISSION_RATE_LOQUALIFIER> <i5:EMISSION_RATE_UNIT> |
|
|
SE09.06.00.1030 |
Remarks [Remarks] |
|
|
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:LEACHING> <i5:set> <i5:LEACHING_REMARKS> <i5:LEACHING_REMARKS> |
|
|
SE09.06.00.1035 |
Validity criteria fulfilled [Validity
criteria fulfilled] |
|
Picklist Values: yes
|| no || no data || not applicable |
Indicate whether the validity criteria given by test guideline have been fulfilled or not. |
Indication of validity criteria and whether they have been fulfilled or not. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:VALIDITY_CRIT_FULFILLED> <i5:set> <i5:PHRASEOTHER_LIST_SEL_FIX> <i5:LIST_SEL_FIX> |
|
SE09.06.00.1036 |
Validity criteria fulfilled [no
label] |
|
|
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:VALIDITY_CRIT_FULFILLED> <i5:set> <i5:PHRASEOTHER_LIST_SEL_FIX> <i5:LIST_SEL_FIX_TXT> |
|
|
SE09.06.00.1040 |
Quality Criteria [Quality
Criteria] |
|
|
Indicate if the Quality Criteria (i.e. accuracy, reproducibility and acceptable range of results) are met, and if not, what effect this has on the study's validity. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:QUALITY_CRITERIA> <i5:set> <i5:TEXT_BELOW> <i5:TEXT_BELOW> |
|
|
SE09.06.00.1045 |
Any other information on results incl. tables [Any
other information on results incl. tables] |
|
|
In this field, you can enter any other information on results, for which no distinct field is available, or transfer free text from other databases. You can also open a rich text editor and create formatted text and tables or insert and edit any excerpt from a word processing or spreadsheet document, provided it was converted to the HTML format. Note: One rich text editor field each is provided for the MATERIALS AND METHODS and RESULTS section. In addition the fields 'Overall remarks' and 'Executive summary' allow rich text entry. |
Rich text editor field for creating formatted text and tables or inserting and editing any excerpt from a word processing or spreadsheet document, provided it was converted to the HTML format. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:REM_RS> <i5:set> <i5:RICHTEXT_BELOW> <i5:RICHTEXT_BELOW> |
|
SE09.06.00.1050 |
OVERALL REMARKS, ATTACHMENTS [Overall
remarks, attachments] |
|
|
|
Main heading under which 'Overall remarks, attachments' fields are subsumed. |
|
|
SE09.06.00.1060 |
Overall remarks [Overall
remarks] |
|
|
In this field, you can enter any overall remarks or transfer free text from other databases. You can also open a rich text editor and create formatted text and tables or insert and edit any excerpt from a word processing or spreadsheet document, provided it was converted to the HTML format. Note: One rich text editor field each is provided for the MATERIALS AND METHODS and RESULTS section. In addition the fields 'Overall remarks' and 'Executive summary' allow rich text entry. |
Rich text editor field for creating formatted text and tables or inserting and editing any excerpt from a word processing or spreadsheet document, provided it was converted to the HTML format. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:REM_ANYOTHER> <i5:set> <i5:RICHTEXT_BELOW> <i5:RICHTEXT_BELOW> |
|
SE09.06.00.1069 |
Attached background material [Attached
background material] |
|
|
Attach any background document that cannot be inserted in any rich text editor field, particularly image files (e.g. an image of a structural formula). Copy this block of fields for attaching more than one file. |
Heading of field block 'Attached document'. |
|
|
SE09.06.00.1070 |
Attached document [Attached
document] |
|
|
Upload file by clicking the upload icon. As appropriate, enter any additional information, e.g. language. The file name is displayed after uploading the document. |
File name of document uploaded, i.e. attached. No restriction as to file type. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:AD> <i5:set> <i5:DOC> <i5:DOC> |
|
SE09.06.00.1080 |
Remarks [Remarks] |
|
|
As appropriate, include remarks, e.g. a short description of the content of the attached document if the file name is not self-explanatory. |
Remarks on attached document. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_EMISSION_PRESERVATIVE> <i5:AD> <i5:set> <i5:REM> <i5:REM> |
|
SE09.06.00.1089 |
Attached full study report [Attached
full study report] |
|
|
If required, an electronic copy of the full study report can be attached as WORD, pdf or other document type, which will not be integrated in any report, but must be handled as separate files. Note: In the export administration you can indicate whether the attached files should be incl |