OECD Template #29: Biodegradation in water and sediment: simulation tests (Version 2-June 2012)

The following table gives a detailed description of the type of information prompted for by the data entry fields. Elements provided to guide the user include predefined picklist phrases, freetext templates and context-sensitive help texts. In addition, technical elements are provided, i.e. field and data types, explanations for use in Data Element Dictionary (DED) and the xml schema. The conventions used are explained in part 'Introduction and Format of OECD Harmonised Templates'.

Field number

Field description

[Field label]

  1. Field type
  2. Data type
  3. Group ID
  4. Max occ.
  5. Detail level
  6. Picklist code

Remarks, Picklist, Freetext template

Help text

Explanation for use in Data Element Dictionary (DED)

XML Schema

 

ADMINISTRATIVE DATA

 

REMARKS:

Under this main heading, fields are subsumed for identifying the purpose of the record (e.g., 'key study'), the type of result (e.g., 'experimental study'), data waiving indication (if any), reliability indication, and flags for indicating the regulatory purpose envisaged and/or any confidentiality restrictions. This kind of data characterise the relevance of a study summary and may therefore be displayed on top of each template. For detailed guidance, refer to Administrative data.

 

 

 

SE05.02.02.0215

DATA SOURCE

[Data source]

  1. HEAD-1
  2. Heading level 1
  3. [N/A]
  4. 1
  5. 1
  6. [N/A]

 

 

Main heading under which generic 'Data source' fields are subsumed.

 

SE05.02.02.0219

Reference

[Reference]

  1. HEAD BLOCK
  2. Block label
  3. g211
  4. 10
  5. 1
  6. [N/A]

 

Indicate the bibliographic reference of the study report or publication the study summary is based on. Always enter the primary reference in the first block of fields (i.e. Sort no. = 1), if there are more than one reference to be cited. Copy this block of fields for specifying any other references related to this record (e.g. report of a preliminary study or other documentation). If results of a study report have been published, indicate the full citation of that publication(s) in addition to the reference of the original study.

Heading of field block 'Reference'

 

SE05.02.02.0220

Reference type

[Reference type]

  1. LIST-OPEN
  2. STRING/255
  3. g211
  4. 1
  5. 1
  6. Z31

Picklist Values:

study report || other company data || publication || review article or handbook || secondary source || grey literature || other:

Indicate the type of reference, e.g. 'Study report' or 'Publication'. Select 'Other company data' to characterise any unpublished information from a company other than a study report. Select 'Grey literature' for any other unpublished information or 'other:' and specify.

Indicator specifying the type of reference, e.g. 'Study report' or 'Publication'.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:REFERENCE>

<i5:set>

<i5:PHRASEOTHER_REFERENCE_TYPE>

<i5:REFERENCE_TYPE>

SE05.02.02.0221

Reference type

[no label]

  1. OTHERTEXT
  2. STRING/255
  3. g211
  4. 1
  5. 1
  6. [N/A]

 

 

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:REFERENCE>

<i5:set>

<i5:PHRASEOTHER_REFERENCE_TYPE>

<i5:REFERENCE_TYPE_TXT>

SE05.02.02.0230

Author(s) (or transferred reference)

[Author]

  1. TEXT
  2. STRING/2000
  3. g211
  4. 1
  5. 1
  6. [N/A]

 

For ease of sorting and searchability use following convention: Surname, Initial (Example 1: White D, Ruehl KJ, Borman SA & Little J. Example 2: Hartley M & Murray W (avoid unnecessary full-stops, commas)). If no individuals are cited as authors, enter name of company or organisation or 'Anon.' as appropriate.

Note that the complete bibliographic reference may appear in this field after migration of unstructured data from existing databases.

Name(s) of author(s) of the study report or publication.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:REFERENCE>

<i5:set>

<i5:REFERENCE_AUTHOR>

<i5:REFERENCE_AUTHOR>

SE05.02.02.0240

Year

[Year]

  1. YEAR
  2. NUMBER/4/###0
  3. g211
  4. 1
  5. 1
  6. [N/A]

 

Enter year of study report or publication. For a study report this field should be completed to include it in any searches, regardless of whether the complete date is given in field 'Report date'.

Year of the study report or publication.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:REFERENCE>

<i5:set>

<i5:REFERENCE_YEAR>

<i5:REFERENCE_YEAR>

SE05.02.02.0250

Title

[Title]

  1. TEXT
  2. STRING/255
  3. g211
  4. 1
  5. 1
  6. [N/A]

 

Include the title of the report. For publications, include the title of the article of a journal or article/chapter of a book (e.g. handbook).

Title of a study report or title of published article of journal or book (e.g. handbook).

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:REFERENCE>

<i5:set>

<i5:REFERENCE_TITLE>

<i5:REFERENCE_TITLE>

SE05.02.02.0260

Bibliographic source

[Bibliographic source]

  1. TEXT
  2. STRING/255
  3. g211
  4. 1
  5. 1
  6. [N/A]

 

Not relevant for any study report. For publications or any other literature source (grey literature) specify the following type of information: (i) Title of scientific journal or book (e.g. if handbook); (ii) Volume of journal; (iii) Editor, publisher, place of publication for books or articles in books; (iv) Pagination.

Example 1 (journal): J. Agric. Food Chem. 38: 215-227

Example 2 (handbook): In: Lyman WJ (ed.) Handbook of chemical property estimation methods. Environmental behavior of organic compounds. McGraw-Hill Book Company 15.1-15.34, New York.

Bibliographic source of the study report or publication.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:REFERENCE>

<i5:set>

<i5:REFERENCE_SOURCE>

<i5:REFERENCE_SOURCE>

SE05.02.02.0270

Testing laboratory

[Testing laboratory]

  1. TEXT
  2. STRING/255
  3. g211
  4. 1
  5. 1
  6. [N/A]

 

Either manually enter the name of the testing laboratory or select it from the picklist. In either case, editing is possible.

Name of the testing laboratory.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:REFERENCE>

<i5:set>

<i5:REFERENCE_TESTLAB>

<i5:REFERENCE_TESTLAB>

SE05.02.02.0280

Report no.

[Report no.]

  1. TEXT
  2. STRING/255
  3. g211
  4. 1
  5. 1
  6. [N/A]

 

Specify the report number allocated by the testing laboratory. Note that any company-specific study number should be included in the respective field.

Report number allocated by the testing laboratory.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:REFERENCE>

<i5:set>

<i5:REFERENCE_REPORT_NO>

<i5:REFERENCE_REPORT_NO>

SE05.02.02.0290

Owner company

[Owner company]

  1. TEXT
  2. STRING/255
  3. g211
  4. 1
  5. 1
  6. [N/A]

 

Either manually enter the identity of the company who owns the data or select it from the picklist. In either case, editing is possible.

Identity of the sponsor company who owns the study report.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:REFERENCE>

<i5:set>

<i5:REFERENCE_COMPANY_ID>

<i5:REFERENCE_COMPANY_ID>

SE05.02.02.0300

Company study no.

[Company study no.]

  1. TEXT
  2. STRING/255
  3. g211
  4. 1
  5. 1
  6. [N/A]

 

Specify any company study no. if there is such a number and if it is different from the report no. of the testing laboratory. Otherwise leave field empty.

Company-specific study number.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:REFERENCE>

<i5:set>

<i5:REFERENCE_COMPANY_STUDY_NO>

<i5:REFERENCE_COMPANY_STUDY_NO>

SE05.02.02.0310

Report date

[Report date]

  1. DATE
  2. DATE/255
  3. g211
  4. 1
  5. 1
  6. [N/A]

 

Specify the complete date of the study report, e.g. '2005-05-12' for 12 May 2005. Note that subfield 'Year' should be completed in any case for sorting and searching purposes.

Complete date of the study report.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:REFERENCE>

<i5:set>

<i5:REFERENCE_REPORT_DATE>

<i5:REFERENCE_REPORT_DATE>

SE05.02.02.0320

Data access

[Data access]

  1. LIST-OPEN
  2. STRING/255
  3. [N/A]
  4. 1
  5. 1
  6. Z03

Picklist Values:

data submitter is data owner || data submitter has Letter of Access || data no longer protected || data published || not applicable || other:

Select appropriate indication for data access. Enter 'Not applicable' if the summary consists of information that is commonly accessible such as guidance on safe use.

Indication for data access.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:DATA_ACCESS>

<i5:set>

<i5:PHRASEOTHER_LIST_POP>

<i5:LIST_POP>

SE05.02.02.0321

Data access

[no label]

  1. OTHERTEXT
  2. STRING/255
  3. [N/A]
  4. 1
  5. 1
  6. [N/A]

 

 

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:DATA_ACCESS>

<i5:set>

<i5:PHRASEOTHER_LIST_POP>

<i5:LIST_POP_TXT>

SE05.02.02.0330

Data protection claimed

[Data protection claimed]

  1. LIST-CLOSED-SUP
  2. STRING/255
  3. [N/A]
  4. 1
  5. 1
  6. Z30

Picklist Values:

yes || yes, but willing to share || yes, but not willing to share

Indicate as appropriate. Note: 'yes' should be selected only if 'Data submitter is data owner' or 'Data submitter has Letter of Access'. Options 'yes, but willing to share' or 'yes, but not willing to share' may be relevant for specific regulatory programmes where the submitter is requested to indicate whether he is willing to share studies (e.g. with vertebrates).

In the supplementary remarks field, include an explanation as appropriate, i.e. justification for denial of sharing the corresponding study or refer to a document attached that provides justification (e.g. 'for justification see attached document X')

Indication if data protection is claimed by the submitter who has to be data owner or have letter of access.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:DATA_PROT_CLAIM>

<i5:set>

<i5:PHRASEOTHER_LIST_POP_FIX>

<i5:LIST_POP_FIX>

SE05.02.02.0331

Data protection claimed

[no label]

  1. SUP-TEXT
  2. STRING/255
  3. [N/A]
  4. 1
  5. 1
  6. [N/A]

 

 

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:DATA_PROT_CLAIM>

<i5:set>

<i5:PHRASEOTHER_LIST_POP_FIX>

<i5:LIST_POP_FIX_TXT>

SE05.02.02.0340

Cross-reference to same study

[Cross-reference to same study]

  1. TEXTAREA
  2. STRING/2000
  3. [N/A]
  4. 1
  5. 1
  6. [N/A]

 

A cross-reference can be included to indicate that the same study is recorded in another record. Indicate the respective chapter and record ID and enter relevant explanatory text. This may be useful if specific endpoints of a given study are described in another chapter (e.g. results on reproduction toxicity in case of a combined repeated dose / reproduction toxicity study) or if more than one experiment is described by the same study report, but included in separate records.

Check with the relevant guidance document whether all the methodology details must be repeated or whether a cross-reference to the same study in another chapter may suffice.

Note that any such cross-reference may become useless if a record is either printed or exchanged on its own.

Indication that the same study is described in another study summary / chapter of the data set.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:CROSSREF_SAMESTUDY>

<i5:set>

<i5:TEXT_BELOW>

<i5:TEXT_BELOW>

SE05.02.02.0345

MATERIALS AND METHODS

[Materials and methods]

  1. HEAD-1
  2. Heading level 1
  3. [N/A]
  4. 1
  5. 1
  6. [N/A]

 

 

Main heading under which generic 'Materials and methods' fields are subsumed.

 

SE05.02.02.0349

Test guideline

[Test guideline]

  1. HEAD BLOCK
  2. Block label
  3. g212
  4. 5
  5. 1
  6. [N/A]

 

Indicate according to which test guideline the study was conducted. If no test guideline was explicitly followed, but the methodology used is equivalent or similar to a specific guideline, you can indicate so in the 'Qualifier' subfield preceding the field 'Guideline'.

Copy this block of fields for specifying more than one guideline (e.g. US EPA in addition to OECD guideline).

Heading of field block 'Guideline'

 

SE05.02.02.0350

Qualifier

[Qualifier]

  1. LIST-CLOSED
  2. STRING/255
  3. g212
  4. 1
  5. 1
  6. Z06

Picklist Values:

according to || equivalent or similar to || no guideline followed || no guideline available || no guideline required

Select appropriate qualifier, i.e.

- 'according to' (if a given test guideline was followed);

- 'equivalent or similar to' (if no test guideline was explicitly followed, but the methodology is equivalent or similar to a specific guideline);

- 'no guideline followed' (if none of above qualifiers apply. If so, fill in field 'Principles of method if other than guideline');

- 'no guideline available' (if so, fill in field 'Principles of method if other than guideline').

- 'no guideline required' (if so, fill in field 'Principles of method if other than guideline').

An indicator signifying how strict the guideline given in the subsequent field 'Guideline' was followed or whether no guideline was used or available/required.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:GUIDELINE>

<i5:set>

<i5:QUALIFIER>

<i5:QUALIFIER>

SE05.02.02.0360

Guideline

[Guideline]

  1. LIST-OPEN-SUP
  2. STRING/255
  3. g212
  4. 1
  5. 1
  6. F26-1b

Picklist Values:

OECD Guideline 303 A (Simulation Test - Aerobic Sewage Treatment. A: Activated Sludge Units) || OECD Guideline 303 B (Simulation Test - Aerobic Sewage Treatment. B. Biofilms) || OECD Guideline 306 (Biodegradability in Seawater) || OECD Guideline 308 (Aerobic and Anaerobic Transformation in Aquatic Sediment Systems) || OECD Guideline 309 (Aerobic Mineralisation in Surface Water - Simulation Biodegradation Test) || EU Method C.10 (Biodegradation: Activated Sludge Simulation Test) || EU Method C.24 (Aerobic and Anaerobic Transformation in Aquatic Sediment Systems) || EPA OPPTS 835.3180 (Sediment / Water Microcosm Biodegradation Test) || EPA OPPTS 835.3220 (Porous Pot Test) || EPA OPPTS 835.4300 (Aerobic Aquatic Metabolism) || EPA OPPTS 835.4400 (Anaerobic Aquatic Metabolism) || EPA OPPTS 835.5154 (Anaerobic Biodegradability in the Subsurface) || EPA OTS 795.54 (Anaerobic Biodegradability in the Subsurface) || EPA Subdivision N Pesticide Guideline 162-3 (Anaerobic Aquatic Metabolism) || EPA Subdivision N Pesticide Guideline 162-4 (Aerobic Aquatic Metabolism) || other guideline:

Select the applicable test guideline, e.g. 'OECD Guideline xxx'. If the test guideline used is not listed, choose 'other guideline:' and specify the test guideline in the related text field.

In this text field, you can also enter any remarks as applicable, particularly:

- To include any other title of the test guideline draft used, a subtitle, another version or update number and the year of update (For instance, different titles and/or numbers may exist for a given EU test guideline.);

- To indicate if a the study was performed prior to the adoption of the test guideline specified;

- To indicate if the methodology used was based on an extension of the test guideline specified.

The name of the guideline followed in performing the study or to which the method used can be compared. Also indication if no guideline was used, availaible or required. In supplementary remarks field indication of guideline version or title if deviating from the picklist value., or of additional test guidelines cited.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:GUIDELINE>

<i5:set>

<i5:PHRASEOTHER_GUIDELINE>

<i5:GUIDELINE>

SE05.02.02.0361

Guideline

[no label]

  1. SUP-TEXT
  2. STRING/255
  3. g212
  4. 1
  5. 1
  6. [N/A]

 

 

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:GUIDELINE>

<i5:set>

<i5:PHRASEOTHER_GUIDELINE>

<i5:GUIDELINE_TXT>

SE05.02.02.0370

Deviations from guideline

[Deviations]

  1. LIST-CLOSED-SUP
  2. STRING/255
  3. g212
  4. 1
  5. 1
  6. Z08

Picklist Values:

yes || no || no data || not applicable

For robust study summaries or as requested by the regulatory programme, indicate if there are any deviations from the test guideline specified. If 'yes' is selected, only briefly state relevant deviations in the supplementary remarks field (e.g. 'other species used'); details should be described in the respective fields of the section MATERIALS AND METHODS.

Indication that a study contains deviations from the standard test protocol.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:GUIDELINE>

<i5:set>

<i5:PHRASEOTHER_DEVIATION>

<i5:DEVIATION>

SE05.02.02.0371

Deviations from guideline

[no label]

  1. SUP-TEXT
  2. STRING/255
  3. g212
  4. 1
  5. 1
  6. [N/A]

 

 

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:GUIDELINE>

<i5:set>

<i5:PHRASEOTHER_DEVIATION>

<i5:DEVIATION_TXT>

SE05.02.02.0380

Principles of method if other than guideline

[Principles of method if other than guideline]

  1. TEXTAREA
  2. STRING/32768
  3. [N/A]
  4. 1
  5. 1
  6. [N/A]

 

If no guideline was followed, include a description of the principles of the test protocol or estimated method used in the study. Details should be entered in appropriate distinct fields of section MATERIALS AND METHODS if available. Also provide a justification for using this method if appropriate.

If an estimation method was used (to be indicated in field 'Study result type') state the equation(s) and/or computer software or other methods applied to calculate the value(s).

Description of the test protocol or estimated method used in the study, if other than a guideline, and justification for using this method if appropriate.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:METHOD_NOGUIDELINE>

<i5:set>

<i5:TEXTAREA_BELOW>

<i5:TEXTAREA_BELOW>

SE05.02.02.0390

GLP compliance

[GLP compliance]

  1. LIST-CLOSED-SUP
  2. STRING/255
  3. [N/A]
  4. 1
  5. 1
  6. Z40

Picklist Values:

yes (incl. certificate) || yes || no || no data

Indicate whether the study was conducted following Good Laboratory Practice or not. Select 'yes (incl. certificate)' if a GLP certificate of a test facility is available. Select 'yes' if a GLP compliance statement is available, but no information on a GLP certificate. You can give an explanation in the supplementary remarks field, e.g. for explaining why GLP was not complied with or for specifying which (national) GLP was followed.

Indication whether a GLP certificate or compliance statement is available.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:GLP_COMPLIANCE_STATEMENT>

<i5:set>

<i5:PHRASEOTHER_LIST_SEL_FIX>

<i5:LIST_SEL_FIX>

SE05.02.02.0391

GLP compliance

[no label]

  1. SUP-TEXT
  2. STRING/255
  3. [N/A]
  4. 1
  5. 1
  6. [N/A]

 

 

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:GLP_COMPLIANCE_STATEMENT>

<i5:set>

<i5:PHRASEOTHER_LIST_SEL_FIX>

<i5:LIST_SEL_FIX_TXT>

SE05.02.02.0395

Test materials

[Test materials]

  1. HEAD-2
  2. Heading level 2
  3. [N/A]
  4. 1
  5. 1
  6. [N/A]

 

 

Subheading of section 'Test materials'

 

SE05.02.02.0400

Test material equivalent to submission substance identity

[Identity of test material same as for substance defined in section 1 (if not read-across)]

  1. LIST-CLOSED
  2. STRING/255
  3. [N/A]
  4. 1
  5. 1
  6. Z38

Picklist Values:

yes || no

Select 'yes' or 'no' from the drop-down list for indicating that the identity of the test material is the same or is not the same, respectively, as for substance defined in section 1 (General information). In addition, the identity of the test material should be specified in the subsequent block of fields 'Test material identity'.

NOTE: You cannot update this field, if a completed record is copied to another submission substance as reference. Therefore, in case of read-across the indication of 'yes' is not relevant.

Indicator showing whether the test material used is equivalent to the submission substance identity.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:TESTMAT_INDICATOR>

<i5:set>

<i5:LIST_BELOW_SEL>

<i5:LIST_BELOW_SEL>

SE05.02.02.0409

Test material identity

[Test material identity]

  1. HEAD BLOCK
  2. Block label
  3. g213
  4. 10
  5. 1
  6. [N/A]

 

Indicate the identity of the test material for one or more appropriate identifiers, e.g. CAS number, CAS name, IUPAC name. Copy this block of fields as appropriate.

NOTE: In order to avoid confusion on the test material identity it is highly recommended to enter at least one substance identifier, regardless of what has been entered in field 'Identity of test material same as for substance defined in section 1 (if not read-across)'.

Heading of field block 'Test material identity'

 

SE05.02.02.0410

Identifier

[Identifier]

  1. LIST-OPEN
  2. STRING/255
  3. g213
  4. 1
  5. 1
  6. Z39

Picklist Values:

CAS name || CAS number || Common name || EC name || EC number || IUPAC name || TSCA name || other:

Select an appropriate identifier from drop-down list, e.g. 'CAS number'. Use 'Other:' and specify, if identity according to a standard identifier is not known or if an additional chemical name or number is provided.

Indicator specifying the type of chemical identifier, e.g. CAS name.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:TESTMAT>

<i5:set>

<i5:PHRASEOTHER_IDENTIFIER>

<i5:IDENTIFIER>

SE05.02.02.0411

Identifier

[no label]

  1. OTHERTEXT
  2. STRING/255
  3. g213
  4. 1
  5. 1
  6. [N/A]

 

 

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:TESTMAT>

<i5:set>

<i5:PHRASEOTHER_IDENTIFIER>

<i5:IDENTIFIER_TXT>

SE05.02.02.0420

Identity

[Identity]

  1. TEXT
  2. STRING/2000
  3. g213
  4. 1
  5. 1
  6. [N/A]

 

Select the corresponding substance identity from drop-down list or enter manually if the identity is not available from the list or if no list is provided for the type of identifier selected.

Identity of the chemical substance used in the study or referred to in the record.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:TESTMAT>

<i5:set>

<i5:ID>

<i5:ID>

SE05.02.02.0425

Physical form

[Test material form]

  1. LIST-OPEN
  2. STRING/255
  3. [N/A]
  4. 1
  5. 1
  6. A101

Picklist Values:

aerosol || compact || crystalline || dispersion || fibre || filaments || flakes || liquified gas || nanomaterial || particulates || paste || pellets || powder || refrigerated liquid || suspension || viscous || other: || no data

Select the test material form from the drop-down list. If the form of the test chemical is not available in the list, select 'other:' and specify in the adjacent field. If the test material form is unknown, select 'no data'.

Form of the substance, i.e. powder, crystalline, compact, viscous, etc.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:TESTMAT_FORM>

<i5:set>

<i5:PHRASEOTHER_TESTMAT_FORM>

<i5:TESTMAT_FORM>

SE05.02.02.0426

Test material form

[no label]

  1. OTHERTEXT
  2. STRING/255
  3. [N/A]
  4. 1
  5. 1
  6. [N/A]

 

 

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:TESTMAT_FORM>

<i5:set>

<i5:PHRASEOTHER_TESTMAT_FORM>

<i5:TESTMAT_FORM_TXT>

SE05.02.02.0430

Radiolabelling

[Radiolabelling]

  1. LIST-CLOSED
  2. STRING/255
  3. [N/A]
  4. 1
  5. 1
  6. F14

Picklist Values:

no || yes || no data

Indicate if labelled or non-labelled test material was used. Details on labelled material to be described in field 'Details on test material'.

Indication whether labelled or non-labelled test material was used.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:RADIO_LABEL>

<i5:set>

<i5:LIST_BELOW_SEL>

<i5:LIST_BELOW_SEL>

SE05.02.02.0440

Details on test material

[Details on test material]

  1. TEXT-TEMPL
  2. STRING/32768
  3. [N/A]
  4. 1
  5. 1
  6. [N/A]

Freetext Templates:

- Name of test material (as cited in study report):

- Molecular formula (if other than submission substance):

- Molecular weight (if other than submission substance):

- Smiles notation (if other than submission substance):

- InChl (if other than submission substance):

- Structural formula attached as image file (if other than submission substance): see Fig.

- Substance type:

- Physical state:

- Analytical purity:

- Impurities (identity and concentrations):

- Composition of test material, percentage of components:

- Isomers composition:

- Purity test date:

- Lot/batch No.:

- Expiration date of the lot/batch:

- Radiochemical purity (if radiolabelling):

- Specific activity (if radiolabelling):

- Locations of the label (if radiolabelling):

- Expiration date of radiochemical substance (if radiolabelling):

- Stability under test conditions:

- Storage condition of test material:

- Other:

Use freetext template and delete/add elements as appropriate. Enter any details that could be relevant for evaluating this study summary or that are requested by the respective regulatory programme. Consult the programme-specific guidance (e.g. OECD HPVC, Pesticides NAFTA or EU REACH) thereof.

Note that any information that can be claimed confidential should be included in the subsequent field 'Confidential details on test material'.

Explanations:

- Name of test material (as cited in study report): only if different from any other identifiers provided in the preceding fields.

- Molecular formula (if other than submission substance): specify

- Molecular weight (if other than submission substance): specify

- Smiles notation (if other than submission substance): provide if available

- InChl (if other than submission substance): provide if available

- Structural formula attached as image file (if other than submission substance): see Fig.: only if different from submission substance. Indicate Fig. no. if a file is attached in field 'Attached document', e.g. state 'see Fig. 1'.

- Substance type: indicate whether pure active substance, technical product, formulation or other.

- Physical state: indicate 'gas', 'solid' or 'liquid' only if different from submission substance or if substance can occur in different physical states.

- Analytical purity: specify in %

- Impurities (identity and concentrations): specify

- Composition of the test material, percentage of components: specify if applicable

- Isomers composition: specify if applicable

- Purity test date: provide if available

- Lot/batch No.: provide if available

- Expiration date of the lot/batch: provide if available

- Radiochemical purity (if radiolabelling): specify if applicable

- Specific activity (if radiolabelling): specify if applicable

- Locations of the label (if radiolabelling): specify if applicable

- Expiration date of radiochemical substance (if radiolabelling): specify if applicable

- Storage condition of test substance: specify if applicable

- Stability under test conditions: indicate if available

Details on description and specification of the actual test material.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:TESTMAT_DETAILS>

<i5:set>

<i5:FREETEXT_BELOW>

<i5:FREETEXT_BELOW>

SE05.02.02.0450

Confidential details on test material

[Confidential details on test material]

  1. TEXT-TEMPL
  2. STRING/32768
  3. [N/A]
  4. 1
  5. 3
  6. [N/A]

Freetext Templates:

- Analytical purity:

- Impurities (identity and concentrations):

- Composition of test material, percentage of components:

- Purity test date:

- Lot/batch No.:

- Expiration date of the lot/batch:

- Isomers composition:

- Other:

Enter any confidential information on the test material in this separate field. Use freetext template and delete/add elements as appropriate. Enter any details that could be relevant for evaluating this study summary or that are requested by the respective regulatory programme. Consult the programme-specific guidance (e.g. OECD HPVC, Pesticides NAFTA or EU REACH) thereof.

Explanations:

- Analytical purity: specify in %

- Impurities (identity and concentrations): specify

- Composition of the test material, percentage of components: specify if applicable

- Purity test date: provide if available

- Lot/batch No.: : provide if available

- Expiration date of the lot/batch: : provide if available

- Isomers composition: specify if applicable

Confidential details on the actual test material.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:TESTMAT_CONFIDENTIAL_DETAILS>

<i5:set>

<i5:FREETEXT_BELOW>

<i5:FREETEXT_BELOW>

SE05.02.02.0460

Details on properties of test surrogate or analogue material

[Details on properties of test surrogate or analogue material]

  1. TEXT-TEMPL
  2. STRING/32768
  3. [N/A]
  4. 1
  5. 2
  6. [N/A]

Freetext Templates:

PHYSICO-CHEMICAL PROPERTIES

- Melting point:

- Boiling point:

- Vapour pressure:

- Henry's law constant (for volatile substances):

- Water solubility (under test conditions):

- Solubility in organic solvents:

- log Pow:

- pKa:

- Base or acid catalysis of test material:

- UV absorption:

- Stability of test material at room temperature:

- pH dependence on stability:

OTHER PROPERTIES (if relevant for this endpoint)

- Adsorption characteristics:

- Toxicity to microorganisms:

- Other:

ONLY if another substance, i.e. analogue or surrogate (e.g. degradation/transformation product) was used as test material, enter any relevant details on the properties of this substance that may possibly affect the test performance, particularly physico-chemical properties.

Use freetext template and delete/add elements as appropriate.

Note that the physico-chemical properties of the substance for which the submission is made should be recorded in the corresponding templates and therefore need not be repeated here. Nevertheless, the possible influence of any physico-chemical properties should be indicated / discussed in appropriate fields, particularly in fields 'Details on study design' and 'Test performance'. This holds also true if any property of the substance is different in the test medium as compared to the data recorded in the section on physico-chemical properties, e.g. lower water solubility.

Details on properties of test material, particularly physico-chemical properties. Relevant if an analogue or surrogate was used.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:PROPERTIES_TESTMAT_DETAILS>

<i5:set>

<i5:FREETEXT_BELOW>

<i5:FREETEXT_BELOW>

SE05.02.02.0465

Study design

[Study design]

  1. HEAD-2
  2. Heading level 2
  3. [N/A]
  4. 1
  5. 1
  6. [N/A]

 

 

Subheading of section 'Study design'

 

SE05.02.02.0470

Oxygen conditions

[Oxygen conditions]

  1. LIST-OPEN-SUP
  2. STRING/255
  3. [N/A]
  4. 1
  5. 1
  6. F25-2

Picklist Values:

aerobic || anaerobic || aerobic/anaerobic || other: || no data

Indicate whether test was performed under aerobic or anaerobic conditions. Select 'aerobic/anaerobic' if both oxygen conditions occur as in water/sediment studies. Include any explanations in the supplementary remarks field as appropriate.

Indication whether test was performed under aerobic or anaerobic conditions.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:OXYGEN_CONDITIONS>

<i5:set>

<i5:PHRASEOTHER_LIST_POP_FIX>

<i5:LIST_POP_FIX>

SE05.02.02.0471

Oxygen conditions

[no label]

  1. SUP-TEXT
  2. STRING/255
  3. [N/A]
  4. 1
  5. 1
  6. [N/A]

 

 

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:OXYGEN_CONDITIONS>

<i5:set>

<i5:PHRASEOTHER_LIST_POP_FIX>

<i5:LIST_POP_FIX_TXT>

SE05.02.02.0480

Inoculum or test system

[Inoculum or test system]

  1. LIST-OPEN
  2. STRING/255
  3. [N/A]
  4. 1
  5. 1
  6. F27-2

Picklist Values:

natural water || natural water / sediment || natural sediment || natural soil || mixture of sewage, soil and natural water || activated sludge (adaptation not specified) || activated sludge, adapted || activated sludge, domestic (adaptation not specified) || activated sludge, domestic, adapted || activated sludge, domestic, non-adapted || activated sludge, industrial (adaptation not specified) || activated sludge, industrial, adapted || activated sludge, industrial, non-adapted || activated sludge, non-adapted || sewage, domestic (adaptation not specified) || sewage, domestic, adapted || sewage, domestic, non-adapted || sewage, industrial (adaptation not specified) || sewage, industrial, adapted || sewage, industrial, non-adapted || sewage, predominantly domestic (adaptation not specified) || sewage, predominantly domestic, adapted || sewage, predominantly domestic, non-adapted || sewage, predominantly industrial (adaptation not specified) || sewage, predominantly industrial, adapted || sewage, predominantly industrial, non-adapted || anaerobic sludge || digested sludge || anaerobic bacteria || anaerobic microorganisms || other: || no data

Select the inoculum used. As far as possible, indicate whether any activated sludge or sewage used was adapted or not. If the study report does not give clear information thereof, select '..... (adaptation not specified)', e.g. 'sewage, domestic (adaptation not specified)'. In this case, give further explanation in field 'Details on inoculum', if any. In field 'Rationale for reliability', discuss the impact of this reporting deficiency on the study results.

If no inoculum was added in the strictest sense, but natural water and/or sediment was used, indicate the corresponding test system, e.g. 'natural water / sediment'.

Note that any simulation tests should be recorded using the corresponding template.

Type of inoculum or test system used.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:INOCULUM>

<i5:set>

<i5:PHRASEOTHER_LIST_POP>

<i5:LIST_POP>

SE05.02.02.0481

Inoculum or test system

[no label]

  1. OTHERTEXT
  2. STRING/255
  3. [N/A]
  4. 1
  5. 1
  6. [N/A]

 

 

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:INOCULUM>

<i5:set>

<i5:PHRASEOTHER_LIST_POP>

<i5:LIST_POP_TXT>

SE05.02.02.0490

Details on inoculum: surface water

[Details on source and properties of surface water]

  1. TEXT-TEMPL
  2. STRING/32768
  3. [N/A]
  4. 1
  5. 2
  6. [N/A]

Freetext Templates:

- Details on collection (e.g. location, sampling depth, contamination history, procedure):

- Storage conditions:

- Storage length:

- Temperature (°C) at time of collection:

- pH at time of collection:

- Electrical conductivity:

- Redox potential (mv) initial/final:

- Oxygen concentration (mg/l) initial/final:

- Hardness (CaCO3):

- Dissolved organic carbon (%):

- Biomass (e.g. in mg microbial C/100 mg, CFU or other):

- Water filtered: yes/no

- Type and size of filter used, if any:

Give details on source and properties of surface water used as inoculum if applicable. Use freetext template and delete/add elements as appropriate.

Details on source and properties of surface water in case of test in natural water samples.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:SURFACEWATER_DETAILS>

<i5:set>

<i5:FREETEXT_BELOW>

<i5:FREETEXT_BELOW>

SE05.02.02.0500

Details on inoculum: sediment

[Details on source and properties of sediment]

  1. TEXT-TEMPL
  2. STRING/32768
  3. [N/A]
  4. 1
  5. 2
  6. [N/A]

Freetext Templates:

- Details on collection (e.g. location, sampling depth, contamination history, procedure):

- Storage conditions:

- Storage length:

- Textural classification (i.e. %sand/silt/clay):

- pH at time of collection:

- Organic carbon (%):

- Redox potential (mv) initial/final:

- CEC (meq/100 g):

- Bulk density (g/cm³):

- Biomass (e.g. in mg microbial C/100 mg, CFU or other):

- Sediment samples sieved: yes/no

Give details on source and properties of sediment used as inoculum if applicable. Use freetext template and delete/add elements as appropriate.

Details on source and properties of sediment in case of water-sediment simulation system.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:SEDIMENT_DETAILS>

<i5:set>

<i5:FREETEXT_BELOW>

<i5:FREETEXT_BELOW>

SE05.02.02.0510

Details on inoculum: other

[Details on inoculum]

  1. TEXT-TEMPL
  2. STRING/32768
  3. [N/A]
  4. 1
  5. 2
  6. [N/A]

Freetext Templates:

- Source of inoculum/activated sludge (e.g. location, sampling depth, contamination history, procedure):

- Laboratory culture:

- Method of cultivation:

- Storage conditions:

- Storage length:

- Preparation of inoculum for exposure:

- Pretreatment:

- Concentration of sludge:

- Initial cell/biomass concentration:

Give details on any other inoculum, e.g. activated sludge if applicable. Use freetext template and delete/add elements as appropriate.

Details on inoculum as appropriate.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:INOCULUM_DETAILS>

<i5:set>

<i5:FREETEXT_BELOW>

<i5:FREETEXT_BELOW>

SE05.02.02.0520

Duration

[Duration of test (contact time)]

  1. LIST-CLOSED
  2. STRING/255
  3. [N/A]
  4. 1
  5. 1
  6. A02-1

Picklist Values:

> || >= || ca.

Enter a numeric value or a range of numeric values according to following conventions:

(i) In the first numeric field, enter a single value (Qualifier subfield left blank) or a value if preceded by '>', '>=' or 'ca.' (e.g. '20', 'ca. 20', '>20').

(ii) In the second numeric field, enter a single value if preceded by '<' or '<='.

(iii) Use both numeric fields and, as required, the lower and upper qualifier field to enter a range of numeric values (e.g. '2 - 8' or '>2 <8').

Test (contact time): Lower qualifier field providing a list with following operators: >, >=, and ca.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:DURATION>

<i5:set>

<i5:PRECISION_LOQUALIFIER>

<i5:LOQUALIFIER>

SE05.02.02.0530

Duration

[no label]

  1. NUM
  2. NUMBER/20/########0.#########
  3. [N/A]
  4. 1
  5. 1
  6. [N/A]

 

 

Test (contact time): Lower numeric field for entering a numeric value preceded either by no operator, '>', '>=' or 'ca.' (e.g. '20', '>20', '>=20', '20')

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:DURATION>

<i5:set>

<i5:PRECISION_LOQUALIFIER>

<i5:LOVALUE>

SE05.02.02.0540

Duration

[no label]

  1. LIST-CLOSED
  2. STRING/255
  3. [N/A]
  4. 1
  5. 1
  6. A02-2

Picklist Values:

< || <= || ca.

 

Test (contact time): Upper qualifier field providing a list with following operators: <, <=, and ca.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:DURATION>

<i5:set>

<i5:PRECISION_LOQUALIFIER>

<i5:UPQUALIFIER>

SE05.02.02.0550

Duration

[no label]

  1. NUM
  2. NUMBER/20/########0.#########
  3. [N/A]
  4. 1
  5. 1
  6. [N/A]

 

 

Test (contact time): Upper numeric field for entering a numeric value only if either a lower value is already entered to specify a numeric range or if the numeric value is preceded by either operator '<' or '<='.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:DURATION>

<i5:set>

<i5:PRECISION_LOQUALIFIER>

<i5:UPVALUE>

SE05.02.02.0560

Unit

[Duration of test (contact time)]

  1. LIST-CLOSED
  2. STRING/255
  3. [N/A]
  4. 1
  5. 1
  6. F05

Picklist Values:

min || h || d || wk || mo || yr

Select from drop-down list.

Unit of time.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:DURATION>

<i5:set>

<i5:PRECISION_LOQUALIFIER>

<i5:UNIT>

SE05.02.02.0569

Initial test substance concentration

[Initial test substance concentration]

  1. HEAD BLOCK
  2. Block label
  3. g214
  4. 10
  5. 1
  6. [N/A]

 

Specify the initial test concentration applied. If different concentrations were used in different test runs, copy this block of fields accordingly. If a range of concentrations is reported, include the lower and upper values in the numeric range field.

If appropriate copy this block of fields for indicating different parameters the initial concentration is based on (e.g. COD and test substance).

Heading of field block 'Initial test substance concentration'.

 

SE05.02.02.0570

Initial concentration

[Initial conc.]

  1. LIST-CLOSED
  2. STRING/255
  3. g214
  4. 1
  5. 1
  6. A02-1

Picklist Values:

> || >= || ca.

Enter a numeric value or a range of numeric values according to following conventions:

(i) In the first numeric field, enter a single value (Qualifier subfield left blank) or a value if preceded by '>', '>=' or 'ca.' (e.g. '20', 'ca. 20', '>20').

(ii) In the second numeric field, enter a single value if preceded by '<' or '<='.

(iii) Use both numeric fields and, as required, the lower and upper qualifier field to enter a range of numeric values (e.g. '2 - 8' or '>2 <8').

Initial concentration: Lower qualifier field providing a list with following operators: >, >=, and ca.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:INITIALCONC>

<i5:set>

<i5:PRECISION_LOQUALIFIER>

<i5:LOQUALIFIER>

SE05.02.02.0580

Initial concentration

[no label]

  1. NUM
  2. NUMBER/20/########0.#########
  3. g214
  4. 1
  5. 1
  6. [N/A]

 

 

Initial concentration: Lower numeric field for entering a numeric value preceded either by no operator, '>', '>=' or 'ca.' (e.g. '20', '>20', '>=20', '20')

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:INITIALCONC>

<i5:set>

<i5:PRECISION_LOQUALIFIER>

<i5:LOVALUE>

SE05.02.02.0590

Initial concentration

[no label]

  1. LIST-CLOSED
  2. STRING/255
  3. g214
  4. 1
  5. 1
  6. A02-2

Picklist Values:

< || <= || ca.

 

Initial concentration: Upper qualifier field providing a list with following operators: <, <=, and ca.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:INITIALCONC>

<i5:set>

<i5:PRECISION_LOQUALIFIER>

<i5:UPQUALIFIER>

SE05.02.02.0600

Initial concentration

[no label]

  1. NUM
  2. NUMBER/20/########0.#########
  3. g214
  4. 1
  5. 1
  6. [N/A]

 

 

Initial concentration: Upper numeric field for entering a numeric value only if either a lower value is already entered to specify a numeric range or if the numeric value is preceded by either operator '<' or '<='.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:INITIALCONC>

<i5:set>

<i5:PRECISION_LOQUALIFIER>

<i5:UPVALUE>

SE05.02.02.0610

Unit

[Initial test substance concentration]

  1. LIST-OPEN
  2. STRING/255
  3. g214
  4. 1
  5. 1
  6. F28

Picklist Values:

g/L || mg/L || mmol/L || mol/L || µg/L || µmol/L || other:

Select from drop-down list. Further information can be given in the supplementary remarks field.

Unit of initial test substance concentration.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:INITIALCONC>

<i5:set>

<i5:PRECISION_LOQUALIFIER>

<i5:UNIT>

SE05.02.02.0611

Unit

[no label]

  1. OTHERTEXT
  2. STRING/255
  3. g214
  4. 1
  5. 1
  6. [N/A]

 

 

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:INITIALCONC>

<i5:set>

<i5:PRECISION_LOQUALIFIER>

<i5:UNIT_TXT>

SE05.02.02.0620

Based on

[Based on]

  1. LIST-OPEN
  2. STRING/255
  3. g214
  4. 1
  5. 1
  6. F29

Picklist Values:

COD || DOC || ThOD/L || ThIC || test mat. || act. ingr. || formulation || other: || no data

From drop-down list, select the parameter on which the initial concentration is based.

Indication of parameter (e.g. COD, DOC) the initial test substance concentration was related to.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:INITIALCONC>

<i5:set>

<i5:PHRASEOTHER_PARAMETER>

<i5:PARAMETER>

SE05.02.02.0621

Based on

[no label]

  1. OTHERTEXT
  2. STRING/255
  3. g214
  4. 1
  5. 1
  6. [N/A]

 

 

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:INITIALCONC>

<i5:set>

<i5:PHRASEOTHER_PARAMETER>

<i5:PARAMETER_TXT>

SE05.02.02.0629

Parameter followed for biodegradation estimation

[Parameter followed for biodegradation estimation]

  1. HEAD BLOCK
  2. Block label
  3. g215
  4. 5
  5. 2
  6. [N/A]

 

Indicate the parameter used to measure biodegradation. Copy field for more than one parameter as appropriate. In supplementary remarks field, give relevant details on the method. For radiochemical measurement or test substance analysis use freetext template in field 'Details on analytical methods'.

Parameter used to measure biodegradation and, in supplementary remarks field, relevant details on the method..

 

SE05.02.02.0630

Parameter followed for biodegradation estimation

[Parameter followed for biodegradation estimation]

  1. LIST-OPEN-SUP
  2. STRING/255
  3. g215
  4. 1
  5. 2
  6. F103

Picklist Values:

CH4 evolution || CO2 evolution || DOC removal || inorg. C analysis || O2 consumption || Radiochem. meas. || Test mat. analysis || TOC removal || other: || no data

Indicate the parameter used to measure biodegradation. Copy field for more than one parameter as appropriate. In supplementary remarks field, give relevant details on the method. For radiochemical measurement or test substance analysis use freetext template in field 'Details on analytical methods'.

Parameter used to measure biodegradation and, in supplementary remarks field, relevant details on the method..

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:PARAMETER_BIODEGRADATION>

<i5:set>

<i5:PHRASEOTHER_LIST_POP_FIX>

<i5:LIST_POP_FIX>

SE05.02.02.0631

Parameter followed for biodegradation estimation

[no label]

  1. SUP-TEXT
  2. STRING/255
  3. g215
  4. 1
  5. 2
  6. [N/A]

 

 

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:PARAMETER_BIODEGRADATION>

<i5:set>

<i5:PHRASEOTHER_LIST_POP_FIX>

<i5:LIST_POP_FIX_TXT>

SE05.02.02.0640

Details on analytical methods

[Details on analytical methods]

  1. TEXT-TEMPL
  2. STRING/32768
  3. [N/A]
  4. 1
  5. 2
  6. [N/A]

Freetext Templates:

DETAILS ON PRETREATMENT

- Digestion (acid used, method: e.g. micro-oven):

- Extraction (solvent used, method: e.g. liquid-liquid, SPE):

- Total 14C measurement:

- Clean up method: e.g. chemical used for chemistry method (Cu, Hg, ...) or phase and solvent used for SPE method:

- Derivatisation method if used:

- Concentration (method):

IDENTIFICATION AND QUANTIFICATION OF PARENT COMPOUND

- Separation method (e.g. HPLC, GC):

- Conditions (column, mobile phase, etc.):

- Detection method (e.g. ECD, UV, MS, ICP-AES, ICP-MS):

- Detection limits (LOD, LOQ) (indicate method of determination/calculation):

- Reproducibility in % (indicate method of evaluation; should be given for stated concentration levels):

- Linearity range:

- Internal or external calibration:

- Extraction recovery (indicate if results are corrected or not for recoveries):

- Recovery ratio of test material from inoculated vs. blank samples:

- Method of confirmation of identity of measured compound:

IDENTIFICATION AND QUANTIFICATION OF TRANSFORMATION PRODUCTS

If the amount of test material in the test solutions was monitored, enter any details on the analytical methods used. Use freetext template and delete/add elements as appropriate. Copy any subheading(s) under IDENTIFICATION AND QUANTIFICATION OF PARENT COMPOUND to include the respective information for transformation products and/or non-extractable residues.

Specify methods for water and sediment if applicable.

Details on the analytical method used.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:ANALYT_METHOD_DETAILS>

<i5:set>

<i5:FREETEXT_BELOW>

<i5:FREETEXT_BELOW>

SE05.02.02.0650

Details on study design

[Details on study design]

  1. TEXT-TEMPL
  2. STRING/32768
  3. [N/A]
  4. 1
  5. 2
  6. [N/A]

Freetext Templates:

TEST CONDITIONS

- Volume of test solution/treatment:

- Composition of medium:

- Additional substrate:

- Solubilising agent (type and concentration if used):

- Test temperature:

- pH:

- pH adjusted: yes/no

- CEC (meq/100 g):

- Aeration of dilution water:

- Suspended solids concentration:

- Continuous darkness: yes/no

- Any indication of the test material adsorbing to the walls of the test apparatus:

- Other:

TEST SYSTEM

- Culturing apparatus:

- Number of culture flasks/concentration:

- Method used to create aerobic conditions:

- Method used to create anaerobic conditions:

- Measuring equipment:

- Test performed in closed vessels due to significant volatility of test substance:

- Test performed in open system:

- Details of trap for CO2 and volatile organics if used:

- Other:

SAMPLING

- Sampling frequency:

- Sampling method:

- Sterility check if applicable:

- Sample storage before analysis:

- Other:

CONTROL AND BLANK SYSTEM

- Inoculum blank:

- Abiotic sterile control:

- Toxicity control:

- Other:

STATISTICAL METHODS:

Use freetext template and delete/add elements as appropriate. Enter any details that could be relevant for evaluating this study summary or that are requested by the respective regulatory programme. Consult the programme-specific guidance (e.g. OECD HPVC, Pesticides NAFTA or EU REACH) thereof.

Details on study design

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:STUDYDESIGN_DETAILS>

<i5:set>

<i5:FREETEXT_BELOW>

<i5:FREETEXT_BELOW>

SE05.02.02.0659

Reference substance

[Reference substance]

  1. HEAD BLOCK
  2. Block label
  3. g216
  4. 5
  5. 2
  6. [N/A]

 

Indicate identity of reference substance(s) used and give details in the supplementary remarks field as appropriate. Repeat field for each substance.

Indication if a test with a reference substance was performed.

 

SE05.02.02.0660

Reference substance

[Reference substance]

  1. LIST-OPEN-SUP
  2. STRING/255
  3. g216
  4. 1
  5. 2
  6. E36

Picklist Values:

aniline || benzoic acid, sodium salt || acetic acid, sodium salt || ethylene glycol || diethylene glycol || laurylsulfonate || other: || not required || no data

Indicate identity of reference substance(s) used and give details in the supplementary remarks field as appropriate. Repeat field for each substance.

Indication if a test with a reference substance was performed.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:REFERENCE_SUBSTANCE>

<i5:set>

<i5:PHRASEOTHER_LIST_POP_FIX>

<i5:LIST_POP_FIX>

SE05.02.02.0661

Reference substance

[no label]

  1. SUP-TEXT
  2. STRING/255
  3. g216
  4. 1
  5. 2
  6. [N/A]

 

 

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:REFERENCE_SUBSTANCE>

<i5:set>

<i5:PHRASEOTHER_LIST_POP_FIX>

<i5:LIST_POP_FIX_TXT>

SE05.02.02.0670

Any other information on materials and methods incl. tables

[Any other information on materials and methods incl. tables]

  1. RICHTEXT
  2. STRING/256000
  3. [N/A]
  4. 1
  5. 1
  6. [N/A]

 

In this field, you can enter any information on materials and methods, for which no distinct field is available, or transfer free text from other databases. You can also open a rich text editor and create formatted text and tables or insert and edit any excerpt from a word processing or spreadsheet document, provided it was converted to the HTML format.

Note: One rich text editor field each is provided for the MATERIALS AND METHODS and RESULTS section. In addition the fields 'Overall remarks' and 'Executive summary' allow rich text entry.

Rich text editor field for creating formatted text and tables or inserting and editing any excerpt from a word processing or spreadsheet document, provided it was converted to the HTML format.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:REM_ME_TC>

<i5:set>

<i5:RICHTEXT_BELOW>

<i5:RICHTEXT_BELOW>

SE05.02.02.0675

RESULTS AND DISCUSSION

[Results and discussions]

  1. HEAD-1
  2. Heading level 1
  3. [N/A]
  4. 1
  5. 1
  6. [N/A]

 

 

Main heading under which generic 'Results and discussion' fields are subsumed.

 

SE05.02.02.0680

Test performance

[Test performance]

  1. TEXTAREA
  2. STRING/2000
  3. [N/A]
  4. 1
  5. 2
  6. [N/A]

 

Report on any unusual observations during test or any other information affecting results. Give reasons for any rejection of the test results if applicable.

Note that any deviations from test procedure should be briefly stated in field 'Deviations from guideline'.

Description of any unusual observations during test, deviations from test procedure or any other information affecting results.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:TEST_PERFORMANCE>

<i5:set>

<i5:TEXT_INT>

<i5:TEXT_INT>

SE05.02.02.0690

Mean total recovery in water

[% in water]

  1. NUM
  2. NUMBER/20/########0.#########
  3. [N/A]
  4. 1
  5. 2
  6. [N/A]

 

Enter numeric value.

Mean total recovery in water.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:MASSBALANCE>

<i5:set>

<i5:WATER_MEAN>

<i5:WATER_MEAN>

SE05.02.02.0700

Standard deviation

[St. dev.]

  1. NUM
  2. NUMBER/20/########0.#########
  3. [N/A]
  4. 1
  5. 2
  6. [N/A]

 

Enter numeric value.

Standard deviation of mean overall recovery.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:MASSBALANCE>

<i5:set>

<i5:WATER_STDEV>

<i5:WATER_STDEV>

SE05.02.02.0710

Mean total recovery in sediment

[% in sediment]

  1. NUM
  2. NUMBER/20/########0.#########
  3. [N/A]
  4. 1
  5. 2
  6. [N/A]

 

Enter numeric value.

Mean total recovery in sediment.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:MASSBALANCE>

<i5:set>

<i5:SEDIMENT_MEAN>

<i5:SEDIMENT_MEAN>

SE05.02.02.0720

Standard deviation

[St. dev.]

  1. NUM
  2. NUMBER/20/########0.#########
  3. [N/A]
  4. 1
  5. 2
  6. [N/A]

 

Enter numeric value.

Standard deviation of mean overall recovery.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:MASSBALANCE>

<i5:set>

<i5:SEDIMENT_STDEV>

<i5:SEDIMENT_STDEV>

SE05.02.02.0730

Remarks

[Remarks]

  1. TEXT
  2. STRING/255
  3. [N/A]
  4. 1
  5. 2
  6. [N/A]

 

Enter any remarks related to the recorded values as appropriate.

Remarks on material balance.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:MASSBALANCE>

<i5:set>

<i5:RM>

<i5:RM>

SE05.02.02.0739

% Degradation of test substance

[% Degradation of test substance]

  1. HEAD BLOCK
  2. Block label
  3. g217
  4. 10
  5. 1
  6. [N/A]

 

Indicate percentage of degradation of test substance including standard deviation at the end of the study period. Indicate the parameter the percentage is based on and the sampling time. Copy this block of fields for recording the percentage values for different parameters.

Note that the degradation at different sampling time points (raw data) should be recorded in below field 'Details on results'.

Heading of field block '% Degradation of test substance'.

 

SE05.02.02.0740

% degradation

[%Degr.]

  1. LIST-CLOSED
  2. STRING/255
  3. g217
  4. 1
  5. 1
  6. A02-1

Picklist Values:

> || >= || ca.

Enter a numeric value or a range of numeric values according to following conventions:

(i) In the first numeric field, enter a single value (Qualifier subfield left blank) or a value if preceded by '>', '>=' or 'ca.' (e.g. '20', 'ca. 20', '>20').

(ii) In the second numeric field, enter a single value if preceded by '<' or '<='.

(iii) Use both numeric fields and, as required, the lower and upper qualifier field to enter a range of numeric values (e.g. '2 - 8' or '>2 <8').

Percentage of degradation of test substance: Lower qualifier field providing a list with following operators: >, >=, and ca.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:DEGRAD>

<i5:set>

<i5:PRECISION_LOQUALIFIER>

<i5:LOQUALIFIER>

SE05.02.02.0750

% degradation

[no label]

  1. NUM
  2. NUMBER/20/########0.#########
  3. g217
  4. 1
  5. 1
  6. [N/A]

 

 

Percentage of degradation of test substance: Lower numeric field for entering a numeric value preceded either by no operator, '>', '>=' or 'ca.' (e.g. '20', '>20', '>=20', '20')

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:DEGRAD>

<i5:set>

<i5:PRECISION_LOQUALIFIER>

<i5:LOVALUE>

SE05.02.02.0760

% degradation

[no label]

  1. LIST-CLOSED
  2. STRING/255
  3. g217
  4. 1
  5. 1
  6. A02-2

Picklist Values:

< || <= || ca.

 

Percentage of degradation of test substance: Upper qualifier field providing a list with following operators: <, <=, and ca.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:DEGRAD>

<i5:set>

<i5:PRECISION_LOQUALIFIER>

<i5:UPQUALIFIER>

SE05.02.02.0770

% degradation

[no label]

  1. NUM
  2. NUMBER/20/########0.#########
  3. g217
  4. 1
  5. 1
  6. [N/A]

 

 

Percentage of degradation of test substance: Upper numeric field for entering a numeric value only if either a lower value is already entered to specify a numeric range or if the numeric value is preceded by either operator '<' or '<='.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:DEGRAD>

<i5:set>

<i5:PRECISION_LOQUALIFIER>

<i5:UPVALUE>

SE05.02.02.0780

Standard deviation

[St. dev.]

  1. NUM
  2. NUMBER/20/########0.#########
  3. g217
  4. 1
  5. 1
  6. [N/A]

 

Enter numeric value.

Standard deviation of percentage of degradation of test substance.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:DEGRAD>

<i5:set>

<i5:STDEV>

<i5:STDEV>

SE05.02.02.0790

Parameter

[Parameter]

  1. LIST-OPEN-SUP
  2. STRING/255
  3. g217
  4. 1
  5. 1
  6. F103

Picklist Values:

CH4 evolution || CO2 evolution || DOC removal || inorg. C analysis || O2 consumption || Radiochem. meas. || Test mat. analysis || TOC removal || other: || no data

From drop-down list, select the parameter on which the percentage is based. Further information can be given in the supplementary remarks field.

Parameter used to measure biodegradation.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:DEGRAD>

<i5:set>

<i5:PHRASEOTHER_PARAMETER>

<i5:PARAMETER>

SE05.02.02.0791

Parameter

[no label]

  1. SUP-TEXT
  2. STRING/255
  3. g217
  4. 1
  5. 1
  6. [N/A]

 

 

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:DEGRAD>

<i5:set>

<i5:PHRASEOTHER_PARAMETER>

<i5:PARAMETER_TXT>

SE05.02.02.0800

Sampling time

[Sampling time]

  1. NUM
  2. NUMBER/20/########0.#########
  3. g217
  4. 1
  5. 1
  6. [N/A]

 

Enter numeric value.

Sampling time

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:DEGRAD>

<i5:set>

<i5:VALUEUNIT_TIMEPOINT_VALUE>

<i5:TIMEPOINT_VALUE>

SE05.02.02.0810

Unit sampling time

[% Degradation of test substance]

  1. LIST-CLOSED
  2. STRING/255
  3. g217
  4. 1
  5. 1
  6. F05

Picklist Values:

min || h || d || wk || mo || yr

Select from drop-down list.

Unit of time.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:DEGRAD>

<i5:set>

<i5:VALUEUNIT_TIMEPOINT_VALUE>

<i5:TIMEPOINT_UNIT>

SE05.02.02.0820

Remarks

[Remarks]

  1. TEXT
  2. STRING/255
  3. g217
  4. 1
  5. 1
  6. [N/A]

 

Enter any remarks related to the recorded values as appropriate.

Remarks

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:DEGRAD>

<i5:set>

<i5:REM>

<i5:REM>

SE05.02.02.0829

Half-life of parent compound / 50% disappearance time (DT50)

[Half-life of parent compound / 50% disappearance time (DT50)]

  1. HEAD BLOCK
  2. Block label
  3. g218
  4. 50
  5. 1
  6. [N/A]

 

Include value (or range if reported so) of half-life and indicate the type of half-life (For first order kinetics DT50 = half-life). For water-sediment systems repeat this block of fields for each compartment.

Heading of field block 'Half-life of parent compound / 50% disappearance time (DT50)'

 

SE05.02.02.0830

Compartment

[Compartment]

  1. LIST-OPEN
  2. STRING/255
  3. g218
  4. 1
  5. 1
  6. F105

Picklist Values:

water || freshwater || marine water || sediment || entire system || other:

Select from drop-down list.

Compartment to which the half-life refers to.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:HALFLIFE>

<i5:set>

<i5:PHRASEOTHER_COMPARTMENT>

<i5:COMPARTMENT>

SE05.02.02.0831

Compartment

[no label]

  1. OTHERTEXT
  2. STRING/255
  3. g218
  4. 1
  5. 1
  6. [N/A]

 

 

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:HALFLIFE>

<i5:set>

<i5:PHRASEOTHER_COMPARTMENT>

<i5:COMPARTMENT_TXT>

SE05.02.02.0840

Half-life

[Half-life]

  1. LIST-CLOSED
  2. STRING/255
  3. g218
  4. 1
  5. 1
  6. A02-1

Picklist Values:

> || >= || ca.

Enter a numeric value or a range of numeric values according to following conventions:

(i) In the first numeric field, enter a single value (Qualifier subfield left blank) or a value if preceded by '>', '>=' or 'ca.' (e.g. '20', 'ca. 20', '>20').

(ii) In the second numeric field, enter a single value if preceded by '<' or '<='.

(iii) Use both numeric fields and, as required, the lower and upper qualifier field to enter a range of numeric values (e.g. '2 - 8' or '>2 <8').

Half life / DT50: Lower qualifier field providing a list with following operators: >, >=, and ca.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:HALFLIFE>

<i5:set>

<i5:PRECISION_LOQUALIFIER>

<i5:LOQUALIFIER>

SE05.02.02.0850

Half-life

[no label]

  1. NUM
  2. NUMBER/20/########0.#########
  3. g218
  4. 1
  5. 1
  6. [N/A]

 

 

Half life / DT50: Lower numeric field for entering a numeric value preceded either by no operator, '>', '>=' or 'ca.' (e.g. '20', '>20', '>=20', '20')

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:HALFLIFE>

<i5:set>

<i5:PRECISION_LOQUALIFIER>

<i5:LOVALUE>

SE05.02.02.0860

Half-life

[no label]

  1. LIST-CLOSED
  2. STRING/255
  3. g218
  4. 1
  5. 1
  6. A02-2

Picklist Values:

< || <= || ca.

 

Half life / DT50: Upper qualifier field providing a list with following operators: <, <=, and ca.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:HALFLIFE>

<i5:set>

<i5:PRECISION_LOQUALIFIER>

<i5:UPQUALIFIER>

SE05.02.02.0870

Half-life

[no label]

  1. NUM
  2. NUMBER/20/########0.#########
  3. g218
  4. 1
  5. 1
  6. [N/A]

 

 

Half life / DT50: Upper numeric field for entering a numeric value only if either a lower value is already entered to specify a numeric range or if the numeric value is preceded by either operator '<' or '<='.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:HALFLIFE>

<i5:set>

<i5:PRECISION_LOQUALIFIER>

<i5:UPVALUE>

SE05.02.02.0880

Unit

[Half-life of parent compound / 50% disappearance time (DT50)]

  1. LIST-CLOSED
  2. STRING/255
  3. g218
  4. 1
  5. 1
  6. F05

Picklist Values:

min || h || d || wk || mo || yr

Select from drop-down list.

Unit of time.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:HALFLIFE>

<i5:set>

<i5:PRECISION_LOQUALIFIER>

<i5:UNIT>

SE05.02.02.0890

St. dev.

[St. dev.]

  1. NUM
  2. NUMBER/20/########0.#########
  3. g218
  4. 1
  5. 1
  6. [N/A]

 

Enter numeric value.

Standard deviation of half-life / DT50.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:HALFLIFE>

<i5:set>

<i5:STDEV>

<i5:STDEV>

SE05.02.02.0900

Type of half-life

[Type]

  1. LIST-OPEN
  2. STRING/255
  3. g218
  4. 1
  5. 1
  6. F136

Picklist Values:

(pseudo-)first order (= DT50) || second order || zero order || other: || no data

Select from drop-down list.

Indicator specifying type of half-life.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:HALFLIFE>

<i5:set>

<i5:PHRASEOTHER_TYPE>

<i5:TYPE>

SE05.02.02.0901

Type of half-life

[no label]

  1. OTHERTEXT
  2. STRING/255
  3. g218
  4. 1
  5. 1
  6. [N/A]

 

 

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:HALFLIFE>

<i5:set>

<i5:PHRASEOTHER_TYPE>

<i5:TYPE_TXT>

SE05.02.02.0905

Temperature

[Temperature]

  1. NUM
  2. NUMBER/20/########0.#########
  3. g218
  4. 1
  5. 1
  6. [N/A]

 

Enter numeric value.

Heading of field block 'Half-life of parent compound / 50% disappearance time (DT50)'

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:HALFLIFE>

<i5:set>

<i5:VALUEUNIT_TEMP_VALUE>

<i5:TEMP_VALUE>

SE05.02.02.0906

Unit

[Half-life of parent compound / 50% disappearance time (DT50)]

  1. LIST-CLOSED
  2. STRING/255
  3. g218
  4. 1
  5. 1
  6. A102

Picklist Values:

°C || K || °F

Select from drop-down list.

Heading of field block 'Half-life of parent compound / 50% disappearance time (DT50)'

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:HALFLIFE>

<i5:set>

<i5:VALUEUNIT_TEMP_VALUE>

<i5:TEMP_UNIT>

SE05.02.02.0910

Remarks (e.g. regression equation, r², DT90)

[Remarks (e.g. regr. equ., r², DT90)]

  1. TEXT
  2. STRING/255
  3. g218
  4. 1
  5. 1
  6. [N/A]

 

For robust study summaries or as requested by the regulatory programme, provide the regression equation, r² , DT90 (with unit) and/or any relevant remarks.

Remarks (e.g. regression equation, r², DT90).

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:HALFLIFE>

<i5:set>

<i5:REM>

<i5:REM>

SE05.02.02.0912

Mineralization rate (in CO2)

[Mineralization rate (in CO2)]

  1. NUM
  2. NUMBER/20/########0.#########
  3. [N/A]
  4. 1
  5. 1
  6. [N/A]

 

Enter Mineralization rate (in CO2)

Mineralization rate (in CO2)

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:MINERALIZATION_RATE>

<i5:set>

<i5:MINRATE>

<i5:MINRATE>

SE05.02.02.0913

Unit for Mineralization rate (in CO2)

[Mineralization rate (in CO2)]

  1. LIST-OPEN
  2. STRING/255
  3. [N/A]
  4. 1
  5. 1
  6. E149

Picklist Values:

w-1 || d-1 || h-1 || min-1 || other:

Enter Unit for Mineralization rate (in CO2)

Unit for Mineralization rate (in CO2)

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:MINERALIZATION_RATE>

<i5:set>

<i5:PHRASEOTHER_MINRATETYPE>

<i5:MINRATETYPE>

SE05.02.02.0914

Unit for Mineralization rate (in CO2)

[no label]

  1. OTHERTEXT
  2. STRING/255
  3. [N/A]
  4. 1
  5. 1
  6. [N/A]

 

 

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:MINERALIZATION_RATE>

<i5:set>

<i5:PHRASEOTHER_MINRATETYPE>

<i5:MINRATETYPE_TXT>

SE05.02.02.0919

Other kinetic parameters

[Other kinetic parameters]

  1. HEAD BLOCK
  2. Block label
  3. g219
  4. 10
  5. 1
  6. [N/A]

 

Include any other relevant kinetic parameters if applicable. Select the respective item from the picklist and include the value in the associated remarks field. Copy this field for each parameter to be entered.

Indication of other relevant kinetic parameters with remarks field for each.

 

SE05.02.02.0920

Other kinetic parameters

[Other kinetic parameters]

  1. LIST-OPEN-SUP
  2. STRING/255
  3. g219
  4. 1
  5. 1
  6. F135

Picklist Values:

first order rate constant || pseudo-first order rate constant || half-saturation constant || maximum specific growth rate || other:

Include any other relevant kinetic parameters if applicable. Select the respective item from the picklist and include the value in the associated remarks field. Copy this field for each parameter to be entered.

Indication of other relevant kinetic parameters with remarks field for each.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:OTHER_KINETIC_PARAMETERS>

<i5:set>

<i5:PHRASEOTHER_LIST_POP_FIX>

<i5:LIST_POP_FIX>

SE05.02.02.0921

Other kinetic parameters

[no label]

  1. SUP-TEXT
  2. STRING/255
  3. g219
  4. 1
  5. 1
  6. [N/A]

 

 

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:OTHER_KINETIC_PARAMETERS>

<i5:set>

<i5:PHRASEOTHER_LIST_POP_FIX>

<i5:LIST_POP_FIX_TXT>

SE05.02.02.0930

Transformation products

[Transformation products]

  1. LIST-CLOSED
  2. STRING/255
  3. [N/A]
  4. 1
  5. 1
  6. E34

Picklist Values:

no || not measured || yes || no data

Indicate whether transformation products occurred. If yes, provide the identified transformation products in following block of fields. Any further details can be entered in field 'Any other information on results incl. tables'.

Indicator that transformation products occurred or not.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:TRANSF_PRODUCTS_INDICATOR>

<i5:set>

<i5:LIST_BELOW_SEL>

<i5:LIST_BELOW_SEL>

SE05.02.02.0939

Identity of transformation products

[Identity of degradation products]

  1. HEAD BLOCK
  2. Block label
  3. g220
  4. 20
  5. 1
  6. [N/A]

 

Indicate the identity of the transformation products using an appropriate identifier, e.g. CAS number, CAS name, IUPAC name. Copy this block of fields for each relevant substance.

Any further details on transformation products can be provided in field 'Any other information on materials and methods incl. tables'.

Heading of field block 'Identity of degradation / transformation products'.

 

SE05.02.02.0940

No.

[No.]

  1. LIST-CLOSED
  2. STRING/255
  3. g220
  4. 1
  5. 1
  6. F137

Picklist Values:

#1 || #2 || #3 || #4 || #5 || #6 || #7 || #8 || #9 || #10 || #11 || #12 || #13 || #14 || #15 || #16 || #17 || #18 || #19 || #20

For easier distinction select a consecutive number for each transformation product from drop-down list if more than one transformation product is entered. If the same substance is identified by more than one identifiers (e.g. by CAS name and Common name), make sure that the same number is allocated to these entries.

Indication of a consecutive number 1-n used to distinguish the degradation / transformation products.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:TRANSF_PRODUCTS_ID>

<i5:set>

<i5:NO>

<i5:NO>

SE05.02.02.0950

Identifier

[Identifier]

  1. LIST-OPEN
  2. STRING/255
  3. g220
  4. 1
  5. 1
  6. Z39

Picklist Values:

CAS name || CAS number || Common name || EC name || EC number || IUPAC name || TSCA name || other:

Select an appropriate identifier from drop-down list, e.g. 'CAS number'. Use 'Other:' if identity according to a standard identifier is not known. Specify if another identifier is provided (e.g. 'Other: xxx').

Indicator specifying the type of chemical identifier, e.g. CAS name.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:TRANSF_PRODUCTS_ID>

<i5:set>

<i5:PHRASEOTHER_IDENTIFIER>

<i5:IDENTIFIER>

SE05.02.02.0951

Identifier

[no label]

  1. OTHERTEXT
  2. STRING/255
  3. g220
  4. 1
  5. 1
  6. [N/A]

 

 

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:TRANSF_PRODUCTS_ID>

<i5:set>

<i5:PHRASEOTHER_IDENTIFIER>

<i5:IDENTIFIER_TXT>

SE05.02.02.0960

Identity

[Identity]

  1. TEXT
  2. STRING/255
  3. g220
  4. 1
  5. 1
  6. [N/A]

 

Select the corresponding substance identity from drop-down list or enter manually if the identity is not available from the list or if no list is provided for the type of identifier selected.

Identity of the chemical substance.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:TRANSF_PRODUCTS_ID>

<i5:set>

<i5:ID>

<i5:ID>

SE05.02.02.0970

Details on transformation products

[Details on transformation products]

  1. TEXT-TEMPL
  2. STRING/32768
  3. [N/A]
  4. 1
  5. 2
  6. [N/A]

Freetext Templates:

- Formation and decline of each transformation product during test:

- Pathways for transformation:

- Other:

Indicate any relevant supplementary information on transformation products. Use freetext template and delete/add items as appropriate. If useful attach a figure in the corresponding field.

Any relevant supplementary information on transformation products.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:TRANSF_PRODUCTS_DETAILS>

<i5:set>

<i5:FREETEXT_BELOW>

<i5:FREETEXT_BELOW>

SE05.02.02.0980

Evaporation of parent compound

[Evaporation of parent compound]

  1. LIST-CLOSED
  2. STRING/255
  3. [N/A]
  4. 1
  5. 2
  6. E34

Picklist Values:

no || not measured || yes || no data

Indicate whether evaporation of the parent compound occurred or not. Include any explanations in field 'Details on results' as appropriate.

Indicator specifying whether evaporation of parent compound occurred.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:DETERM_EVAPORATION>

<i5:set>

<i5:LIST_BELOW_SEL>

<i5:LIST_BELOW_SEL>

SE05.02.02.0990

Volatile metabolites

[Volatile metabolites]

  1. LIST-CLOSED
  2. STRING/255
  3. [N/A]
  4. 1
  5. 2
  6. E34

Picklist Values:

no || not measured || yes || no data

Indicate whether volatile metabolites were found or not. Include any explanations in field 'Details on results' as appropriate.

Indicator specifying whether volatile metabolites were found.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:DETERM_VOLATILE_METABOLITES>

<i5:set>

<i5:LIST_BELOW_SEL>

<i5:LIST_BELOW_SEL>

SE05.02.02.1000

Residues

[Residues]

  1. LIST-CLOSED
  2. STRING/255
  3. [N/A]
  4. 1
  5. 2
  6. E34

Picklist Values:

no || not measured || yes || no data

Indicate whether residues were found or not. Include any explanations in field 'Details on results' as appropriate.

Indicator specifying whether residues were found.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:DETERM_RESIDUES>

<i5:set>

<i5:LIST_BELOW_SEL>

<i5:LIST_BELOW_SEL>

SE05.02.02.1010

Details on results

[Details on results]

  1. TEXT-TEMPL
  2. STRING/32768
  3. [N/A]
  4. 1
  5. 2
  6. [N/A]

REMARKS:

Available predefined table(s) are displayed below, after this template. See also List of Predefined Tables in Annex 2.

Freetext Templates:

TEST CONDITIONS

- Aerobicity (or anaerobicity), moisture, temperature and other experimental conditions maintained throughout the study: Yes/No

- Anomalies or problems encountered (if yes):

MAJOR TRANSFORMATION PRODUCTS

- Range of maximum concentrations in % of the applied amount and day(s) of incubation when observed:

- Range of maximum concentrations in % of the applied amount at end of study period:

on the - the and -th day of incubation, respectively. At the end of the study period, the corresponding concentrations were - and -- % of the applied amount, respectively.

MINOR TRANSFORMATION PRODUCTS

- Range of maximum concentrations in % of the applied amount and day(s) of incubation when observed:

- Range of maximum concentrations in % of the applied amount at end of study period:

TOTAL UNIDENTIFIED RADIOACTIVITY (RANGE) OF APPLIED AMOUNT:

EXTRACTABLE RESIDUES

- % of applied amount at day 0:

- % of applied amount at end of study period:

NON-EXTRACTABLE RESIDUES

- % of applied amount at day 0:

- % of applied amount at end of study period:

MINERALISATION

- % of applied radioactivity present as CO2 at end of study:

VOLATILIZATION

- % of the applied radioactivity present as volatile organics at end of study:

STERILE TREATMENTS (if used)

- Transformation of the parent compound:

- Formation of transformation products:

- Formation of extractable and non-extractable residues:

- Volatilization:

RESULTS OF SUPPLEMENTARY EXPERIMENT (if any):

Indicate any further relevant details of test results. Use freetext template and delete/add elements as appropriate. As appropriate or requested by the regulatory programme include table(s) with raw data in the rich text field 'Any other information on results incl. tables'. Upload predefined table(s) if any or adapt table(s) from study report. Use table numbers in the sequence in which you refer to them in the text (e.g. '... see Table 1').

In field 'Attached background material', attach graph(s) with the full degradation or elimination curves.

TEST CONDITIONS: If the test conditions were not maintained, describe any anomalies or problems encountered.

MAJOR / MINOR TRANSFORMATION PRODUCTS: Indicate concentration ranges of the transformation products specified in the defined field 'Identity of transformation products' or specify if no major transformation products were detected. Tabulate comprehensive data and refer to respective table no. (use predefined table if any) or other appropriate table.

STERILE TREATMENTS: If used, report the transformation of the parent, and compare the results with those of the non-sterile treatments:

SUPPLEMENTARY EXPERIMENT: Briefly describe the results of the supplementary experiment, if any.

Details on results

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:RESULTS_DETAILS>

<i5:set>

<i5:FREETEXT_BELOW>

<i5:FREETEXT_BELOW>

SE05.02.02.1020

Results with reference substance

[Results with reference substance]

  1. TEXTAREA
  2. STRING/2000
  3. [N/A]
  4. 1
  5. 2
  6. [N/A]

 

Indicate whether the results with the reference substance(s) are valid.

Indication whether the results with the reference substance(s) are valid.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:RS_REF_SUBSTANCE>

<i5:set>

<i5:TEXT_INT>

<i5:TEXT_INT>

SE05.02.02.1030

Any other information on results incl. tables

[Any other information on results incl. tables]

  1. RICHTEXT
  2. STRING/256000
  3. [N/A]
  4. 1
  5. 1
  6. [N/A]

 

In this field, you can enter any other remarks on results. You can also open a rich text editor and create formatted text and tables or insert and edit any excerpt from a word processing or spreadsheet document, provided it was converted to the HTML format.

Note: Both the 'Materials and methods' section and 'Results' section. In addition the fields 'Overall remarks' and 'Executive summary' allow rich text entry.

Rich text editor field for creating formatted text and tables or inserting and editing any excerpt from a word processing or spreadsheet document, provided it was converted to the HTML format.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:REM_RS>

<i5:set>

<i5:RICHTEXT_BELOW>

<i5:RICHTEXT_BELOW>

SE05.02.02.1035

OVERALL REMARKS, ATTACHMENTS

[Overall remarks, attachments]

  1. HEAD-1
  2. Heading level 1
  3. [N/A]
  4. 1
  5. 1
  6. [N/A]

 

 

Main heading under which 'Overall remarks, attachments' fields are subsumed.

 

SE05.02.02.1040

Remarks on results including tables and figures

[Remarks on results including tables and figures]

  1. RICHTEXT
  2. STRING/256000
  3. [N/A]
  4. 1
  5. 1
  6. [N/A]

 

In this field, you can enter any overall remarks or transfer free text from other databases. You can also open a rich text editor and create formatted text and tables or insert and edit any excerpt from a word processing or spreadsheet document, provided it was converted to the HTML format.

Note: One rich text editor field each is provided for the MATERIALS AND METHODS and RESULTS section. In addition the fields 'Overall remarks' and 'Executive summary' allow rich text entry.

Rich text editor field for creating formatted text and tables or inserting and editing any excerpt from a word processing or spreadsheet document, provided it was converted to the HTML format.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:REM_ANYOTHER>

<i5:set>

<i5:RICHTEXT_BELOW>

<i5:RICHTEXT_BELOW>

SE05.02.02.1049

Attached background material

[Attached background material]

  1. HEAD BLOCK
  2. Block label
  3. g221
  4. 10
  5. 1
  6. [N/A]

 

Attach any background document that cannot be inserted in any rich text editor field, particularly image files (e.g. an image of a structural formula).

Copy this block of fields for attaching more than one file.

Heading of field block 'Attached document'.

 

SE05.02.02.1050

Attached document

[Attached document]

  1. ATTACHMENT
  2. STRING/32768
  3. g221
  4. 1
  5. 1
  6. [N/A]

 

Upload file by clicking the upload icon. As appropriate, enter any additional information, e.g. language. The file name is displayed after uploading the document.

File name of document uploaded, i.e. attached. No restriction as to file type.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:AD>

<i5:set>

<i5:DOC>

<i5:DOC>

SE05.02.02.1060

Remarks

[Remarks]

  1. TEXT
  2. STRING/255
  3. g221
  4. 1
  5. 1
  6. [N/A]

 

As appropriate, include remarks, e.g. a short description of the content of the attached document if the file name is not self-explanatory.

Remarks on attached document.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:AD>

<i5:set>

<i5:REM>

<i5:REM>

SE05.02.02.1069

Attached full study report

[Attached full study report]

  1. HEAD BLOCK
  2. Block label
  3. g222
  4. 10
  5. 1
  6. [N/A]

 

If required, an electronic copy of the full study report can be attached as WORD, pdf or other document type, which will not be integrated in any report, but must be handled as separate files.

Note: In the export administration you can indicate whether the attached files should be included in the data export or not.

Attached full study report

 

SE05.02.02.1070

Attached full study report

[Attached full study report]

  1. ATTACHMENT
  2. STRING/32768
  3. g222
  4. 1
  5. 1
  6. [N/A]

 

Upload file by clicking the upload icon. As appropriate, enter any additional information, e.g. language. The file name is displayed after uploading the document.

Attached full study report

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:AD_STUDYREPORT>

<i5:set>

<i5:ATTACHMENT_BELOW>

<i5:ATTACHMENT_BELOW>

SE05.02.02.1072

Illustration (picture/graph)

[Illustration (picture/graph)]

  1. PICTURE
  2. STRING/32768
  3. [N/A]
  4. 1
  5. 1
  6. [N/A]

 

Upload file by clicking the upload icon. As appropriate, enter any additional information, e.g. language. The file name is displayed after uploading the document.

Illustration (picture/graph)

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:PG_ILLUSTRATION>

<i5:set>

<i5:PIC_BELOW>

<i5:PIC_BELOW>

SE05.02.02.1075

APPLICANT'S SUMMARY AND CONCLUSION

[Applicant's summary and conclusion]

  1. HEAD-1
  2. Heading level 1
  3. [N/A]
  4. 1
  5. 1
  6. [N/A]

 

 

Main heading under which generic 'Applicant's summary and conclusion' fields are subsumed.

 

SE05.02.02.1080

Validity criteria fulfilled

[Validity criteria fulfilled]

  1. LIST-CLOSED-SUP
  2. STRING/255
  3. [N/A]
  4. 1
  5. 1
  6. F102

Picklist Values:

yes || no || no data || not applicable

Indicate whether validity criteria given by test guideline have been fulfilled or not. Use supplementary remarks field for indicating the criteria and entering remarks. Clearly indicate if the criteria used are not consistent with those given by the test guideline. If so, give justification in field 'Rationale for reliability incl. deficiencies' as to why this study summary is considered reliable.

Indication of validity criteria and whether they have been fulfilled or not.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:VALIDITY_CRIT_SUBM>

<i5:set>

<i5:PHRASEOTHER_LIST_SEL_FIX>

<i5:LIST_SEL_FIX>

SE05.02.02.1081

Validity criteria fulfilled

[no label]

  1. SUP-TEXT
  2. STRING/255
  3. [N/A]
  4. 1
  5. 1
  6. [N/A]

 

 

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:VALIDITY_CRIT_SUBM>

<i5:set>

<i5:PHRASEOTHER_LIST_SEL_FIX>

<i5:LIST_SEL_FIX_TXT>

SE05.02.02.1090

Conclusions

[Conclusions]

  1. TEXTAREA
  2. STRING/32768
  3. [N/A]
  4. 1
  5. 1
  6. [N/A]

 

Enter any conclusions if applicable.

Any conclusions either as adapted from the study report / publication or indicated by the submitter.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:APPL_CL>

<i5:set>

<i5:TEXTAREA_BELOW>

<i5:TEXTAREA_BELOW>

SE05.02.02.1100

Executive summary

[Executive summary]

  1. RICHTEXT
  2. STRING/256000
  3. [N/A]
  4. 1
  5. 1
  6. [N/A]

REMARKS:

Available predefined executive summary is shown below, at the end of this template. See also List of Predefined Executive Summaries in Annex 3.

If required by the respective national/regional programme, briefly summarise the relevant aspects of the study including the conclusions reached. If a specific format is prescribed, upload the respective freetext template if available from the drop-down list or copy it from the corresponding document.

Consult the programme-specific guidance (e.g. OECD HPVC, Pesticides NAFTA or EU REACH) thereof.

Executive summary in which the relevant aspects of the study including the conclusions reached are briefly summarised.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:APPL_EXEC_SUM>

<i5:set>

<i5:RICHTEXT_BELOW>

<i5:RICHTEXT_BELOW>

SE05.02.02.1110

Cross-reference to other study

[Cross-reference to other study]

  1. TEXTAREA
  2. STRING/2000
  3. [N/A]
  4. 1
  5. 1
  6. [N/A]

 

A Cross-reference to other study or other studies can be included which are considered relevant in the interpretation of the test results, e.g. for supporting the conclusion that an effect observed was not substance-related. Indicate the respective chapter(s) and record ID(s) and enter relevant explanatory text.

Such cross-references may be useful if it is considered relevant to discuss other results at the summary level of a single study. It should be noted that the overall appraisal of results from different studies is normally done in the hazard or risk assessment.

Note that any such cross-reference may become useless if a record is either printed or exchanged on its own.

A cross-reference to another study or other studies including explanatory text on why other results are relevant in the interpretation of the results of a given study, e.g. for supporting any conclusions.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_BIODEG_WATER_SIM>

<i5:CROSSREF_OTHER_STUDY>

<i5:set>

<i5:TEXT_BELOW>

<i5:TEXT_BELOW>