The following table gives a
detailed description of the type of information prompted for by the data entry
fields. Elements provided to guide the user include predefined picklist phrases, freetext
templates and context-sensitive help texts. In addition, technical elements are
provided, i.e. field and data types, explanations for use in Data Element
Dictionary (DED) and the xml schema. The conventions used are explained in part
'Introduction
and Format of OECD Harmonised Templates'.
|
Field description [Field label] |
|
Remarks, Picklist, Freetext
template |
Help text |
Explanation for use in Data Element Dictionary (DED) |
XML Schema |
|
|
|
ADMINISTRATIVE
DATA |
|
REMARKS: Under
this main heading, fields are subsumed for identifying the purpose of the
record (e.g., 'key study'), the type of result
(e.g., 'experimental study'), data waiving indication (if any), reliability
indication, and flags for indicating the regulatory purpose envisaged and/or
any confidentiality restrictions. This kind of data characterise
the relevance of a study summary and may therefore be displayed on top of
each template. For detailed guidance, refer to Administrative data. |
|
|
|
|
SE05.01.04.0215 |
DATA SOURCE [Data
source] |
|
|
|
Main heading under which generic 'Data source' fields are subsumed. |
|
|
SE05.01.04.0219 |
Reference [Reference] |
|
|
Indicate the bibliographic reference of the study report or publication the study summary is based on. Always enter the primary reference in the first block of fields (i.e. Sort no. = 1), if there are more than one reference to be cited. Copy this block of fields for specifying any other references related to this record (e.g. report of a preliminary study or other documentation). If results of a study report have been published, indicate the full citation of that publication(s) in addition to the reference of the original study. |
Heading of field block 'Reference' |
|
|
SE05.01.04.0220 |
Reference type [Reference
type] |
|
Picklist Values: study
report || other company data || publication || review article or handbook ||
secondary source || grey literature || other: |
Indicate the type of reference, e.g. 'Study report' or 'Publication'. Select 'Other company data' to characterise any unpublished information from a company other than a study report. Select 'Grey literature' for any other unpublished information or 'other:' and specify. |
Indicator specifying the type of reference, e.g. 'Study report' or 'Publication'. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:REFERENCE> <i5:set> <i5:PHRASEOTHER_REFERENCE_TYPE> <i5:REFERENCE_TYPE> |
|
SE05.01.04.0221 |
Reference type [no
label] |
|
|
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:REFERENCE> <i5:set> <i5:PHRASEOTHER_REFERENCE_TYPE> <i5:REFERENCE_TYPE_TXT> |
|
|
SE05.01.04.0230 |
Author(s) (or transferred reference) [Author] |
|
|
For ease of sorting and searchability use following convention: Surname, Initial (Example 1: White D, Ruehl KJ, Borman SA & Little J. Example 2: Hartley M & Murray W (avoid unnecessary full-stops, commas)). If no individuals are cited as authors, enter name of company or organisation or 'Anon.' as appropriate. Note that the complete bibliographic reference may appear in this field after migration of unstructured data from existing databases. |
Name(s) of author(s) of the study report or publication. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:REFERENCE> <i5:set> <i5:REFERENCE_AUTHOR> <i5:REFERENCE_AUTHOR> |
|
SE05.01.04.0240 |
Year [Year] |
|
|
Enter year of study report or publication. For a study report this field should be completed to include it in any searches, regardless of whether the complete date is given in field 'Report date'. |
Year of the study report or publication. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:REFERENCE> <i5:set> <i5:REFERENCE_YEAR> <i5:REFERENCE_YEAR> |
|
SE05.01.04.0250 |
Title [Title] |
|
|
Include the title of the report. For publications, include the title of the article of a journal or article/chapter of a book (e.g. handbook). |
Title of a study report or title of published article of journal or book (e.g. handbook). |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:REFERENCE> <i5:set> <i5:REFERENCE_TITLE> <i5:REFERENCE_TITLE> |
|
SE05.01.04.0260 |
Bibliographic source [Bibliographic
source] |
|
|
Not relevant for any study report. For publications or any other literature source (grey literature) specify the following type of information: (i) Title of scientific journal or book (e.g. if handbook); (ii) Volume of journal; (iii) Editor, publisher, place of publication for books or articles in books; (iv) Pagination. Example 1 (journal): J. Agric. Food Chem. 38: 215-227 Example 2 (handbook): In: Lyman WJ (ed.) Handbook of chemical property estimation methods. Environmental behavior of organic compounds. McGraw-Hill Book Company 15.1-15.34, New York. |
Bibliographic source of the study report or publication. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:REFERENCE> <i5:set> <i5:REFERENCE_SOURCE> <i5:REFERENCE_SOURCE> |
|
SE05.01.04.0270 |
Testing laboratory [Testing
laboratory] |
|
|
Either manually enter the name of the testing laboratory or select it from the picklist. In either case, editing is possible. |
Name of the testing laboratory. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:REFERENCE> <i5:set> <i5:REFERENCE_TESTLAB> <i5:REFERENCE_TESTLAB> |
|
SE05.01.04.0280 |
Report no. [Report
no.] |
|
|
Specify the report number allocated by the testing laboratory. Note that any company-specific study number should be included in the respective field. |
Report number allocated by the testing laboratory. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:REFERENCE> <i5:set> <i5:REFERENCE_REPORT_NO> <i5:REFERENCE_REPORT_NO> |
|
SE05.01.04.0290 |
Owner company [Owner
company] |
|
|
Either manually enter the identity of the company who owns the data or select it from the picklist. In either case, editing is possible. |
Identity of the sponsor company who owns the study report. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:REFERENCE> <i5:set> <i5:REFERENCE_COMPANY_ID> <i5:REFERENCE_COMPANY_ID> |
|
SE05.01.04.0300 |
Company study no. [Company
study no.] |
|
|
Specify any company study no. if there is such a number and if it is different from the report no. of the testing laboratory. Otherwise leave field empty. |
Company-specific study number. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:REFERENCE> <i5:set> <i5:REFERENCE_COMPANY_STUDY_NO> <i5:REFERENCE_COMPANY_STUDY_NO> |
|
SE05.01.04.0310 |
Report date [Report
date] |
|
|
Specify the complete date of the study report, e.g. '2005-05-12' for 12 May 2005. Note that subfield 'Year' should be completed in any case for sorting and searching purposes. |
Complete date of the study report. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:REFERENCE> <i5:set> <i5:REFERENCE_REPORT_DATE> <i5:REFERENCE_REPORT_DATE> |
|
SE05.01.04.0320 |
Data access [Data
access] |
|
Picklist Values: data
submitter is data owner || data submitter has Letter of Access || data no
longer protected || data published || not applicable || other: |
Select appropriate indication for data access. Enter 'Not applicable' if the summary consists of information that is commonly accessible such as guidance on safe use. |
Indication for data access. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:DATA_ACCESS> <i5:set> <i5:PHRASEOTHER_LIST_POP> <i5:LIST_POP> |
|
SE05.01.04.0321 |
Data access [no
label] |
|
|
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:DATA_ACCESS> <i5:set> <i5:PHRASEOTHER_LIST_POP> <i5:LIST_POP_TXT> |
|
|
SE05.01.04.0330 |
Data protection claimed [Data
protection claimed] |
|
Picklist Values: yes
|| yes, but willing to share || yes, but not willing to share |
Indicate as appropriate. Note: 'yes' should be selected only if 'Data submitter is data owner' or 'Data submitter has Letter of Access'. Options 'yes, but willing to share' or 'yes, but not willing to share' may be relevant for specific regulatory programmes where the submitter is requested to indicate whether he is willing to share studies (e.g. with vertebrates). In the supplementary remarks field, include an explanation as appropriate, i.e. justification for denial of sharing the corresponding study or refer to a document attached that provides justification (e.g. 'for justification see attached document X') |
Indication if data protection is claimed by the submitter who has to be data owner or have letter of access. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:DATA_PROT_CLAIM> <i5:set> <i5:PHRASEOTHER_LIST_POP_FIX> <i5:LIST_POP_FIX> |
|
SE05.01.04.0331 |
Data protection claimed [no
label] |
|
|
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:DATA_PROT_CLAIM> <i5:set> <i5:PHRASEOTHER_LIST_POP_FIX> <i5:LIST_POP_FIX_TXT> |
|
|
SE05.01.04.0340 |
Cross-reference to same study [Cross-reference
to same study] |
|
|
A cross-reference can be included to indicate that the same study is recorded in another record. Indicate the respective chapter and record ID and enter relevant explanatory text. This may be useful if specific endpoints of a given study are described in another chapter (e.g. results on reproduction toxicity in case of a combined repeated dose / reproduction toxicity study) or if more than one experiment is described by the same study report, but included in separate records. Check with the relevant guidance document whether all the methodology details must be repeated or whether a cross-reference to the same study in another chapter may suffice. Note that any such cross-reference may become useless if a record is either printed or exchanged on its own. |
Indication that the same study is described in another study summary / chapter of the data set. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:CROSSREF_SAMESTUDY> <i5:set> <i5:TEXT_BELOW> <i5:TEXT_BELOW> |
|
SE05.01.04.0345 |
MATERIALS AND METHODS [Materials
and methods] |
|
|
|
Main heading under which generic 'Materials and methods' fields are subsumed. |
|
|
SE05.01.04.0349 |
Test guideline [Test
guideline] |
|
|
Indicate according to which test guideline the study was conducted. If no test guideline was explicitly followed, but the methodology used is equivalent or similar to a specific guideline, you can indicate so in the 'Qualifier' subfield preceding the field 'Guideline'. Copy this block of fields for specifying more than one guideline (e.g. US EPA in addition to OECD guideline). |
Heading of field block 'Guideline' |
|
|
SE05.01.04.0350 |
Qualifier [Qualifier] |
|
Picklist Values: according
to || equivalent or similar to || no guideline followed || no guideline
available || no guideline required |
Select appropriate qualifier, i.e. - 'according to' (if a given test guideline was followed); - 'equivalent or similar to' (if no test guideline was explicitly followed, but the methodology is equivalent or similar to a specific guideline); - 'no guideline followed' (if none of above qualifiers apply. If so, fill in field 'Principles of method if other than guideline'); - 'no guideline available' (if so, fill in field 'Principles of method if other than guideline'). - 'no guideline required' (if so, fill in field 'Principles of method if other than guideline'). |
An indicator signifying how strict the guideline given in the subsequent field 'Guideline' was followed or whether no guideline was used or available/required. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:GUIDELINE> <i5:set> <i5:QUALIFIER> <i5:QUALIFIER> |
|
SE05.01.04.0360 |
Guideline [Guideline] |
|
Picklist Values: OECD
Guideline draft (Phototransformation of Chemicals
on Soil Surfaces) || EPA Guideline Subdivision N 161-3 (Photodegradation
Studies on Soil) || other guideline: |
Select the applicable test guideline, e.g. 'OECD Guideline xxx'. If the test guideline used is not listed, choose 'other guideline:' and specify the test guideline in the related text field. In this text field, you can also enter any remarks as applicable, particularly: - To include any other title of the test guideline draft used, a subtitle, another version or update number and the year of update (For instance, different titles and/or numbers may exist for a given EU test guideline.); - To indicate if a the study was performed prior to the adoption of the test guideline specified; - To indicate if the methodology used was based on an extension of the test guideline specified. |
The name of the guideline followed in performing the study or to which the method used can be compared. Also indication if no guideline was used, available or required. In supplementary remarks field indication of guideline version or title if deviating from the picklist value., or of additional test guidelines cited. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:GUIDELINE> <i5:set> <i5:PHRASEOTHER_GUIDELINE> <i5:GUIDELINE> |
|
SE05.01.04.0361 |
Guideline [no
label] |
|
|
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:GUIDELINE> <i5:set> <i5:PHRASEOTHER_GUIDELINE> <i5:GUIDELINE_TXT> |
|
|
SE05.01.04.0370 |
Deviations from guideline [Deviations] |
|
Picklist Values: yes
|| no || no data || not applicable |
For robust study summaries or as requested by the regulatory programme, indicate if there are any deviations from the test guideline specified. If 'yes' is selected, only briefly state relevant deviations in the supplementary remarks field (e.g. 'other species used'); details should be described in the respective fields of the section MATERIALS AND METHODS. |
Indication that a study contains deviations from the standard test protocol. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:GUIDELINE> <i5:set> <i5:PHRASEOTHER_DEVIATION> <i5:DEVIATION> |
|
SE05.01.04.0371 |
Deviations from guideline [no
label] |
|
|
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:GUIDELINE> <i5:set> <i5:PHRASEOTHER_DEVIATION> <i5:DEVIATION_TXT> |
|
|
SE05.01.04.0380 |
Principles of method if other than guideline [Principles
of method if other than guideline] |
|
|
If no guideline was followed, include a description of the principles of the test protocol or estimated method used in the study. Details should be entered in appropriate distinct fields of section MATERIALS AND METHODS if available. Also provide a justification for using this method if appropriate. If an estimation method was used (to be indicated in field 'Study result type') state the equation(s) and/or computer software or other methods applied to calculate the value(s). |
Description of the test protocol or estimated method used in the study, if other than a guideline, and justification for using this method if appropriate. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:METHOD_NOGUIDELINE> <i5:set> <i5:TEXTAREA_BELOW> <i5:TEXTAREA_BELOW> |
|
SE05.01.04.0390 |
GLP compliance [GLP
compliance] |
|
Picklist Values: yes
(incl. certificate) || yes || no || no data |
Indicate whether the study was conducted following Good Laboratory Practice or not. Select 'yes (incl. certificate)' if a GLP certificate of a test facility is available. Select 'yes' if a GLP compliance statement is available, but no information on a GLP certificate. You can give an explanation in the supplementary remarks field, e.g. for explaining why GLP was not complied with or for specifying which (national) GLP was followed. |
Indication whether a GLP certificate or compliance statement is available. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:GLP_COMPLIANCE_STATEMENT> <i5:set> <i5:PHRASEOTHER_LIST_SEL_FIX> <i5:LIST_SEL_FIX> |
|
SE05.01.04.0391 |
GLP compliance [no
label] |
|
|
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:GLP_COMPLIANCE_STATEMENT> <i5:set> <i5:PHRASEOTHER_LIST_SEL_FIX> <i5:LIST_SEL_FIX_TXT> |
|
|
SE05.01.04.0395 |
Test materials [Test
materials] |
|
|
|
Subheading of section 'Test materials' |
|
|
SE05.01.04.0400 |
Test material equivalent to submission substance identity [Identity
of test material same as for substance defined in section 1 (if not
read-across)] |
|
Picklist Values: yes
|| no |
Select 'yes' or 'no' from the drop-down list for indicating that the identity of the test material is the same or is not the same, respectively, as for substance defined in section 1 (General information). In addition, the identity of the test material should be specified in the subsequent block of fields 'Test material identity'. NOTE: You cannot update this field, if a completed record is copied to another submission substance as reference. Therefore, in case of read-across the indication of 'yes' is not relevant. |
Indicator showing whether the test material used is equivalent to the submission substance identity. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:TESTMAT_INDICATOR> <i5:set> <i5:LIST_BELOW_SEL> <i5:LIST_BELOW_SEL> |
|
SE05.01.04.0409 |
Test material identity [Test
material identity] |
|
|
Indicate the identity of the test material for one or more appropriate identifiers, e.g. CAS number, CAS name, IUPAC name. Copy this block of fields as appropriate. NOTE: In order to avoid confusion on the test material identity it is highly recommended to enter at least one substance identifier, regardless of what has been enterd in field 'Identity of test material same as for substance defined in section 1 (if not read-across)'. |
Heading of field block 'Test material identity' |
|
|
SE05.01.04.0410 |
Identifier [Identifier] |
|
Picklist Values: CAS
name || CAS number || Common name || EC name || EC number || IUPAC name ||
TSCA name || other: |
Select an appropriate identifier from drop-down list, e.g. 'CAS number'. Use 'Other:' and specify, if identity according to a standard identifier is not known or if an additional chemical name or number is provided. |
Indicator specifying the type of chemical identifier, e.g. CAS name. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:TESTMAT> <i5:set> <i5:PHRASEOTHER_IDENTIFIER> <i5:IDENTIFIER> |
|
SE05.01.04.0411 |
Identifier [no
label] |
|
|
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:TESTMAT> <i5:set> <i5:PHRASEOTHER_IDENTIFIER> <i5:IDENTIFIER_TXT> |
|
|
SE05.01.04.0420 |
Identity [Identity] |
|
|
Select the corresponding substance identity from drop-down list or enter manually if the identity is not available from the list or if no list is provided for the type of identifier selected. |
Identity of the chemical substance used in the study or referred to in the record. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:TESTMAT> <i5:set> <i5:ID> <i5:ID> |
|
SE05.01.04.0425 |
Physical form [Test
material form] |
|
Picklist Values: aerosol
|| compact || crystalline || dispersion || fibre ||
filaments || flakes || liquified gas ||
nanomaterial || particulates || paste || pellets || powder || refrigerated
liquid || suspension || viscous || other: || no data |
Select the test material form from the drop-down list. If the form of the test chemical is not available in the list, select 'other:' and specify in the adjacent field. If the test material form is unknown, select 'no data'. |
Form of the substance, i.e. powder, crystalline, compact, viscous, etc. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:TESTMAT_FORM> <i5:set> <i5:PHRASEOTHER_TESTMAT_FORM> <i5:TESTMAT_FORM> |
|
SE05.01.04.0426 |
Test material form [no
label] |
|
|
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:TESTMAT_FORM> <i5:set> <i5:PHRASEOTHER_TESTMAT_FORM> <i5:TESTMAT_FORM_TXT> |
|
|
SE05.01.04.0430 |
Radiolabelling [Radiolabelling] |
|
Picklist Values: no
|| yes || no data |
Indicate if labelled or non-labelled test material was used. Details on labelled material should be described in field 'Details on test material'. |
Indication whether labelled or non-labelled test material was used. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:RADIO_LABEL> <i5:set> <i5:LIST_BELOW_SEL> <i5:LIST_BELOW_SEL> |
|
SE05.01.04.0440 |
Details on test material [Details
on test material] |
|
Freetext Templates: - Name of test material (as cited in study report): - Molecular formula (if other than submission substance): - Molecular weight (if other than submission substance): - Smiles notation (if other than submission substance): - InChl (if other than submission substance): - Structural formula attached as image file (if other than submission substance): see Fig. - Substance type: - Physical state: - Analytical purity: - Impurities (identity and concentrations): - Composition of test material, percentage of components: - Isomers composition: - Purity test date: - Lot/batch No.: - Expiration date of the lot/batch: - Radiochemical purity (if radiolabelling): - Specific activity (if radiolabelling): - Locations of the label (if radiolabelling): - Expiration date of radiochemical substance (if radiolabelling): - Stability under test conditions: - Storage condition of test material: - Other: |
Use freetext template and delete/add elements as appropriate. Enter any details that could be relevant for evaluating this study summary or that are requested by the respective regulatory programme. Consult the programme-specific guidance (e.g. OECD HPVC, Pesticides NAFTA or EU REACH) thereof. Note that any information that can be claimed confidential should be included in the subsequent field 'Confidential details on test material'. Explanations: - Name of test material (as cited in study report): only if different from any other identifiers provided in the preceding fields. - Molecular formula (if other than submission substance): specify - Molecular weight (if other than submission substance): specify - Smiles notation (if other than submission substance): provide if available - InChl (if other than submission substance): provide if available - Structural formula attached as image file (if other than submission substance): see Fig.: only if different from submission substance. Indicate Fig. no. if a file is attached in field 'Attached document', e.g. state 'see Fig. 1'. - Substance type: indicate whether pure active substance, technical product, formulation or other. - Physical state: indicate 'gas', 'solid' or 'liquid' only if different from submission substance or if substance can occur in different physical states. - Analytical purity: specify in % - Impurities (identity and concentrations): specify - Composition of the test material, percentage of components: specify if applicable - Isomers composition: specify if applicable - Purity test date: provide if available - Lot/batch No.: provide if available - Expiration date of the lot/batch: provide if available - Radiochemical purity (if radiolabelling): specify if applicable - Specific activity (if radiolabelling): specify if applicable - Locations of the label (if radiolabelling): specify if applicable - Expiration date of radiochemical substance (if radiolabelling): specify if applicable - Storage condition of test substance: specify if applicable - Stability under test conditions: indicate if available |
Details on description and specification of the actual test material. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:TESTMAT_DETAILS> <i5:set> <i5:FREETEXT_BELOW> <i5:FREETEXT_BELOW> |
|
SE05.01.04.0450 |
Confidential details on test material [Confidential
details on test material] |
|
Freetext Templates: - Analytical purity: - Impurities (identity and concentrations): - Composition of test material, percentage of components: - Purity test date: - Lot/batch No.: - Expiration date of the lot/batch: - Isomers composition: - Other: |
Enter any confidential information on the test material in this separate field. Use freetext template and delete/add elements as appropriate. Enter any details that could be relevant for evaluating this study summary or that are requested by the respective regulatory programme. Consult the programme-specific guidance (e.g. OECD HPVC, Pesticides NAFTA or EU REACH) thereof. Explanations: - Analytical purity: specify in % - Impurities (identity and concentrations): specify - Composition of the test material, percentage of components: specify if applicable - Purity test date: provide if available - Lot/batch No.: : provide if available - Expiration date of the lot/batch: : provide if available - Isomers composition: specify if applicable |
Confidential details on the actual test material. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:TESTMAT_CONFIDENTIAL_DETAILS> <i5:set> <i5:FREETEXT_BELOW> <i5:FREETEXT_BELOW> |
|
SE05.01.04.0460 |
Details on properties of test surrogate or analogue material [Details
on properties of test surrogate or analogue material] |
|
Freetext Templates: PHYSICO-CHEMICAL PROPERTIES - UV-VIS absorption: - Water solubility: - Solubility in organic solvents: - Vapour pressure: - log Pow: - Adsorption coefficient: - Chemical stability in the dark (hydrolysis): - Other: OTHER PROPERTIES - Aerobic and anaerobic transformation in soil: - Phototransformation in water: - Other: |
ONLY if another substance, i.e. analogue or surrogate (e.g. degradation/transformation product) was used as test material, enter any relevant details on the properties of this substance that may possibly affect the test performance, particularly physico-chemical properties. Use freetext template and delete/add elements as appropriate. Note that the physico-chemical properties of the substance for which the submission is made should be recorded in the corresponding templates and therefore need not be repeated here. Nevertheless, the possible influence of any physico-chemical properties should be indicated / discussed in appropriate fields, particularly in fields 'Details on test conditions' and 'Test performance'. This holds also true if any property of the substance is different in the test medium as compared to the data recorded in the section on physico-chemical properties. |
Details on properties of test material, particularly physico-chemical properties. Relevant if an analogue or surrogate was used. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:PROPERTIES_TESTMAT_DETAILS> <i5:set> <i5:FREETEXT_BELOW> <i5:FREETEXT_BELOW> |
|
SE05.01.04.0465 |
Study design [Study
design] |
|
|
|
Subheading of section 'Study design' |
|
|
SE05.01.04.0470 |
Analytical monitoring [Analytical
monitoring] |
|
Picklist Values: yes
|| no || no data || not required |
Indicate whether test substance was monitored in the test solutions. For robust study summaries or as requested by the regulatory programme, provide further details on sampling and analytical methods in the corresponding freetext fields. |
Indicator that instrumental analyses were applied to detect the precise amount of chemical exposed to the organisms throughout the experiment. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:ANALYT_MONIT> <i5:set> <i5:LIST_BELOW_SEL> <i5:LIST_BELOW_SEL> |
|
SE05.01.04.0479 |
Analytical method [Analytical
method] |
|
|
Indicate which method was used. Copy field for more than one method. If not available from picklist, select 'other' and specify. |
Analytical method used. |
|
|
SE05.01.04.0480 |
Analytical method [Analytical
method] |
|
Picklist Values: HPLC
|| GC || TLC || other: || no data |
Indicate which method was used. Copy field for more than one method. If not available from picklist, select 'other' and specify. |
Analytical method used. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:ANALYT_METHOD_AQUA> <i5:set> <i5:PHRASEOTHER_LIST_POP> <i5:LIST_POP> |
|
SE05.01.04.0481 |
Analytical method [no
label] |
|
|
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:ANALYT_METHOD_AQUA> <i5:set> <i5:PHRASEOTHER_LIST_POP> <i5:LIST_POP_TXT> |
|
|
SE05.01.04.0490 |
Details on sampling [Details
on sampling] |
|
Freetext Templates: - Sampling intervals of soil samples: - Sampling method: - Sampling method for CO2: - Sampling methods for the volatile compounds, if any: - Sampling intervals/times for - Sterility check, if any: - Measurement of moisture content: - Sample storage conditions before analysis: - Other observation, if any: |
Enter details on sampling regime and method. Use freetext template as appropriate. |
Details on sampling. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:SAMPLING_DETAILS> <i5:set> <i5:FREETEXT_BELOW> <i5:FREETEXT_BELOW> |
|
SE05.01.04.0500 |
Details on analytical methods [Details
on analytical methods] |
|
Freetext Templates: DETAILS ON PRETREATMENT - Digestion (acid used, method: e.g. micro-oven): - Extraction (solvent used, method: e.g. solid/liquid by soxhlet or ASE): - Total 14C measurement: - Clean up method: e.g. chemical used for chemistry method (Cu, Hg, ...) or phase and solvent used for SPE method: - Derivatisation method if used: - Concentration (method): IDENTIFICATION AND QUANTIFICATION OF PARENT COMPOUND - Separation method (e.g. HPLC, GC): - Conditions (column, mobile phase, etc.): - Detection method (e.g. ECD, UV, MS, ICP-AES, ICP-MS): - Detection limits (LOD, LOQ) (indicate method of determination/calculation): - Reproducibility in % (indicate method of evaluation; should be given for stated concentration levels): - Linearity range: - Internal or external calibration: - Extraction recovery (indicate if results are corrected or not for recoveries): - Method of confirmation of identity of measured compound: IDENTIFICATION AND QUANTIFICATION OF TRANSFORMATION PRODUCTS |
If the amount of test material in the test solutions was monitored, enter any details on the analytical methods used. Use freetext template and delete/add elements as appropriate. Copy any subheading(s) under IDENTIFICATION AND QUANTIFICATION OF PARENT COMPOUND to include the respective information for transformation products. |
Details on the analytical method used. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:ANALYT_METHOD_DETAILS> <i5:set> <i5:FREETEXT_BELOW> <i5:FREETEXT_BELOW> |
|
SE05.01.04.0510 |
Details on soil [Details
on soil] |
|
Freetext Templates: COLLECTION AND STORAGE - Geographic location: - Pesticide use history at the collection site: - Collection procedures: - Sampling depth (cm): - Storage and transport conditions: - Storage length: - Soil preparation (e.g.: 2 mm sieved; air dried etc.): PROPERTIES - Soil classification system and year: - Soil texture - % sand: - % silt: - % clay: - pH: - Organic carbon (%): - CEC (meq/100 g): - Initial moisture at 1/3 atm (%): - Water holding capacity: - Bulk density (g/cm3): - Initial microbial biomass/microbial population (unit): - Final microbial biomass/microbial population (unit): PREPARATION OF SOIL - Condition of soil: - Air dried / fresh: - Sterile / non-sterile: - Sterilisation method: |
Using freetext template give details on the soil used. As an alternative option, attach a document e.g. excerpt from the study report. Note: If applicable, indicate the title and year of the soil classification system used after the respective prompt, i.e. Canadian System of Soil Classification / DIN 19863 (Deutsche Industrie-Norm) / NF X31-107 (Norme francaise) / USDA (US Department of Agriculture) / WRB (World Reference Base for Soil Resources) / or other (to be specified). |
Details on soil used. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:SOIL_DETAILS> <i5:set> <i5:FREETEXT_BELOW> <i5:FREETEXT_BELOW> |
|
SE05.01.04.0520 |
Light source [Light
source] |
|
Picklist Values: sunlight
|| Xenon lamp || other: || no data |
Select light source used. |
Indicator specifying what light source was used, i.e. sun light or Xenon lamp. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:LIGHT_SOURCE> <i5:set> <i5:PHRASEOTHER_LIST_POP> <i5:LIST_POP> |
|
SE05.01.04.0521 |
Light source [no
label] |
|
|
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:LIGHT_SOURCE> <i5:set> <i5:PHRASEOTHER_LIST_POP> <i5:LIST_POP_TXT> |
|
|
SE05.01.04.0530 |
Light spectrum: wavelength in nm [Light
spectrum: wavelength in nm] |
|
Picklist Values: >
|| >= || ca. |
Include wavelength (in nm) range of the indicated light source. Not applicable if light source is sunlight. Enter a numeric value or a range of numeric values according to following conventions: (i) In the first numeric field, enter a single value (Qualifier subfield left blank) or a value if preceded by '>', '>=' or 'ca.' (e.g. '20', 'ca. 20', '>20'). (ii) In the second numeric field, enter a single value if preceded by '<' or '<='. (iii) Use both numeric fields and, as required, the lower and upper qualifier field to enter a range of numeric values (e.g. '2 - 8' or '>2 <8'). |
Wavelength (in nm) of the indicated light source: Lower qualifier field providing a list with following operators: >, >=, and ca. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:LIGHTSPECTRUM> <i5:set> <i5:PRECISION_LOQUALIFIER> <i5:LOQUALIFIER> |
|
SE05.01.04.0540 |
Light spectrum: wavelength in nm [no
label] |
|
|
|
Wavelength (in nm) of the indicated light source: Lower numeric field for entering a numeric value preceded either by no operator, '>', '>=' or 'ca.' (e.g. '20', '>20', '>=20', '20') |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:LIGHTSPECTRUM> <i5:set> <i5:PRECISION_LOQUALIFIER> <i5:LOVALUE> |
|
SE05.01.04.0550 |
Light spectrum: wavelength in nm [no
label] |
|
Picklist Values: <
|| <= || ca. |
|
Wavelength (in nm) of the indicated light source: Upper qualifier field providing a list with following operators: <, <=, and ca. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:LIGHTSPECTRUM> <i5:set> <i5:PRECISION_LOQUALIFIER> <i5:UPQUALIFIER> |
|
SE05.01.04.0560 |
Light spectrum: wavelength in nm [no
label] |
|
|
|
Wavelength (in nm) of the indicated light source: Upper numeric field for entering a numeric value only if either a lower value is already entered to specify a numeric range or if the numeric value is preceded by either operator '<' or '<='. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:LIGHTSPECTRUM> <i5:set> <i5:PRECISION_LOQUALIFIER> <i5:UPVALUE> |
|
SE05.01.04.0570 |
Relative light intensity [Relative
light intensity] |
|
Picklist Values: >
|| >= || ca. |
Include the relative intensity of light based on sunlight or its range as appropriate. Enter a numeric value or a range of numeric values according to following conventions: (i) In the first numeric field, enter a single value (Qualifier subfield left blank) or a value if preceded by '>', '>=' or 'ca.' (e.g. '20', 'ca. 20', '>20'). (ii) In the second numeric field, enter a single value if preceded by '<' or '<='. (iii) Use both numeric fields and, as required, the lower and upper qualifier field to enter a range of numeric values (e.g. '2 - 8' or '>2 <8'). |
Relative intensity of light based on sunlight: Lower qualifier field providing a list with following operators: >, >=, and ca. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:LIGHTINTENSITY> <i5:set> <i5:PRECISION_LOQUALIFIER> <i5:LOQUALIFIER> |
|
SE05.01.04.0580 |
Relative light intensity [no
label] |
|
|
|
Relative intensity of light based on sunlight: Lower numeric field for entering a numeric value preceded either by no operator, '>', '>=' or 'ca.' (e.g. '20', '>20', '>=20', '20') |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:LIGHTINTENSITY> <i5:set> <i5:PRECISION_LOQUALIFIER> <i5:LOVALUE> |
|
SE05.01.04.0590 |
Relative light intensity [no
label] |
|
Picklist Values: <
|| <= || ca. |
|
Relative intensity of light based on sunlight: Upper qualifier field providing a list with following operators: <, <=, and ca. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:LIGHTINTENSITY> <i5:set> <i5:PRECISION_LOQUALIFIER> <i5:UPQUALIFIER> |
|
SE05.01.04.0600 |
Relative light intensity [no
label] |
|
|
|
Relative intensity of light based on sunlight: Upper numeric field for entering a numeric value only if either a lower value is already entered to specify a numeric range or if the numeric value is preceded by either operator '<' or '<='. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:LIGHTINTENSITY> <i5:set> <i5:PRECISION_LOQUALIFIER> <i5:UPVALUE> |
|
SE05.01.04.0610 |
Details on light source [Details
on light source] |
|
Freetext Templates: - Emission wavelength spectrum: - Filters used and their purpose: - Light intensity at sample and area irradiated: - Relative light intensity based on intensity of sunlight: - Duration of light/darkness: - Other:- Location: - Latitude: - Longitude: - Hours of daylight: - Time of year/month: - Light intensity: - Duration of light/darkness: - Other: |
Enter any relevant details on the light source. Use either of the two freetext templates as appropriate. As an alternative option, attach a document e.g. excerpt from the study report. |
Further details on light source. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:LIGHT_SOURCE_DETAILS> <i5:set> <i5:FREETEXT_BELOW> <i5:FREETEXT_BELOW> |
|
SE05.01.04.0620 |
Details on test conditions [Details
on test conditions] |
|
Freetext Templates: TEST SYSTEM - Type, material and volume of test apparatus or thin layers: - Application procedure: - Volume of test solution used/treatment: - Method of application: - Co-solvent evaporated: [yes/no] - Details of traps for volatile, if any: - If no traps were used, type of test system: [closed/open] - Indication of test material adsorbing to the walls of test apparatus: [yes: /no] PREPARATION OF THIN-LAYER PLATES: REPLICATION - No. of replicates (dark): - No. of replicates (irradiated): MAINTENANCE OF TEST CONDITIONS SPECIFIED UNDER 'DURATION' - Temperature maintenance method: - Moisture maintenance method: OTHER |
Use freetext template and delete/add elements as appropriate. Enter any details that could be relevant for evaluating this study summary or that are requested by the respective regulatory programme. Consult the programme-specific guidance (e.g. OECD HPVC, Pesticides NAFTA or EU REACH) thereof. |
Further details on test conditions. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:TESTCONDIT_DETAILS> <i5:set> <i5:FREETEXT_BELOW> <i5:FREETEXT_BELOW> |
|
SE05.01.04.0629 |
Duration of test at given test condition [Duration
of test at given test condition] |
|
|
Indicate the test duration and % moisture, temperature and initial test substance concentration at which test was conducted. If test runs with different conditions and durations were performed, copy this block of fields as appropriate. |
Heading of field block 'Duration of test at given pH, temperature an initial concentration of test substance'. |
|
|
SE05.01.04.0630 |
Duration [Duration] |
|
|
Enter numeric value. |
Numeric value of duration of test. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:DURATION> <i5:set> <i5:VALUEUNIT_VALUE> <i5:VALUE> |
|
SE05.01.04.0640 |
Unit [Duration
of test at given test condition] |
|
Picklist Values: min
|| h || d || wk || mo || yr |
Select from drop-down list. |
Unit of test duration. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:DURATION> <i5:set> <i5:VALUEUNIT_VALUE> <i5:UNIT> |
|
SE05.01.04.0650 |
% moisture [%Moisture] |
|
|
Enter numeric value. |
Numeric value of moisture (in %) to which the duration given applies. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:DURATION> <i5:set> <i5:MOISTURE> <i5:MOISTURE> |
|
SE05.01.04.0660 |
Temperature [Temp.] |
|
|
Enter numeric value. |
Numeric value of temperature to which the duration given applies. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:DURATION> <i5:set> <i5:VALUEUNIT_TEMP_VALUE> <i5:TEMP_VALUE> |
|
SE05.01.04.0670 |
Unit [Duration
of test at given test condition] |
|
Picklist Values: °C
|| K || °F |
Select from drop-down list. |
Unit of temperature. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:DURATION> <i5:set> <i5:VALUEUNIT_TEMP_VALUE> <i5:TEMP_UNIT> |
|
SE05.01.04.0680 |
Initial measured concentration [Initial
conc. measured] |
|
|
Enter numeric value. |
Numeric value of initial test substance concentration. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:DURATION> <i5:set> <i5:VALUEUNIT_INITIAL_CONC_VALUE> <i5:INITIAL_CONC_VALUE> |
|
SE05.01.04.0690 |
Unit [Duration
of test at given test condition] |
|
Picklist Values: mg/kg
soil d.w. || g/kg soil d.w.
|| g/ha d.w. || kg/ha d.w.
|| ppm || other: |
Select from drop-down list. |
Unit of initial test substance concentration. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:DURATION> <i5:set> <i5:VALUEUNIT_INITIAL_CONC_VALUE> <i5:INITIAL_CONC_UNIT> |
|
SE05.01.04.0691 |
Unit [no
label] |
|
|
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:DURATION> <i5:set> <i5:VALUEUNIT_INITIAL_CONC_VALUE> <i5:INITIAL_CONC_UNIT_TXT> |
|
|
SE05.01.04.0700 |
Reference substance [Reference
substance] |
|
Picklist Values: yes
|| no || no data |
Indicate if test(s) with a substance with known photolysis was performed. If yes, report the identity of the substance in the supplementary remarks field. |
Indication if reference substance(s) was/were tested. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:REFERENCE_SUBSTANCE> <i5:set> <i5:PHRASEOTHER_LIST_SEL_FIX> <i5:LIST_SEL_FIX> |
|
SE05.01.04.0701 |
Reference substance [no
label] |
|
|
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:REFERENCE_SUBSTANCE> <i5:set> <i5:PHRASEOTHER_LIST_SEL_FIX> <i5:LIST_SEL_FIX_TXT> |
|
|
SE05.01.04.0710 |
Dark controls [Dark
controls] |
|
Picklist Values: yes
|| no || no data |
Indicate if dark, i.e. negative controls were used in parallel studies. Remarks can be included in the supplementary remarks field. |
Indication if dark controls were used. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:DARK_CONTROLS> <i5:set> <i5:PHRASEOTHER_LIST_SEL_FIX> <i5:LIST_SEL_FIX> |
|
SE05.01.04.0711 |
Dark controls [no
label] |
|
|
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:DARK_CONTROLS> <i5:set> <i5:PHRASEOTHER_LIST_SEL_FIX> <i5:LIST_SEL_FIX_TXT> |
|
|
SE05.01.04.0720 |
Computational methods [Computational
methods] |
|
|
Enter details on computational methods used to calculate relevant parameters. |
Computational methods used to calculate relevant parameters, e.g. molar absorption coefficient. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:COMPUTATIONAL_METHODS> <i5:set> <i5:TEXT_INT> <i5:TEXT_INT> |
|
SE05.01.04.0730 |
Any other information on materials and methods incl. tables [Any
other information on materials and methods incl. tables] |
|
|
In this field, you can enter any information on materials and methods, for which no distinct field is available, or transfer free text from other databases. You can also open a rich text editor and create formatted text and tables or insert and edit any excerpt from a word processing or spreadsheet document, provided it was converted to the HTML format. Note: One rich text editor field each is provided for the MATERIALS AND METHODS and RESULTS section. In addition the fields 'Overall remarks' and 'Executive summary' allow rich text entry. |
Rich text editor field for creating formatted text and tables or inserting and editing any excerpt from a word processing or spreadsheet document, provided it was converted to the HTML format. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:REM_ME_TC> <i5:set> <i5:RICHTEXT_BELOW> <i5:RICHTEXT_BELOW> |
|
SE05.01.04.0735 |
RESULTS AND DISCUSSION [Results
and discussions] |
|
|
|
Main heading under which generic 'Results and discussion' fields are subsumed. |
|
|
SE05.01.04.0740 |
Preliminary study [Preliminary
study] |
|
|
Describe results from preliminary study performed, if any (e.g., adsorption of test material to the walls of the test container). |
Results from preliminary study performed, if any |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:PRELIM_STUDY_RS> <i5:set> <i5:TEXT_INT> <i5:TEXT_INT> |
|
SE05.01.04.0750 |
Test performance [Test
performance] |
|
|
Report on any unusual observations during test, deviations from test procedure or any other information affecting results. |
Description of any unusual observations during test, deviations from test procedure or any other information affecting results. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:TEST_PERFORMANCE> <i5:set> <i5:TEXT_INT> <i5:TEXT_INT> |
|
SE05.01.04.0759 |
Spectrum of substance [Spectrum
of substance] |
|
|
Select spectral parameter from picklist and enter value in the subsequent subfield. Any notes can be included in subfield 'Remarks'. Copy block of fields for each parameter cited in the study report. If the substance absorbs light at wavelengths >295 nm, give the wavelength (lambda value) of maximum absorption at wavelengths >295 nm and the maximum molar absorption (extinction) coefficient (epsilon value). If there is no absorption maximum at >295 nm, give the molar extinction coefficient at 295 nm. An alternative to the above is to attach a file that depicts graphically or in tabular form the complete UV/VIS absorption spectrum (include reference to respective Figure or Table No. in subfield 'Remarks'). |
Heading of field block 'Spectrum of substance' |
|
|
SE05.01.04.0760 |
Parameter [Parameter] |
|
Picklist Values: max
lambda || max epsilon || epsilon 295 nm || other: || not applicable || no
data |
Select parameter from drop-down list and enter the corresponding value or range with unit (unless dimensionless) in the related text field, together with any explanation if necessary, e.g. on the study group the result refers to. Explanations: AUC: Area under the plasma (blood) level vs. time curve from zero up to a certain measured time point (specify the time); Cmax: Maximum (peak) concentration; C(time): Maximum concentration at a specified time after administration of a given dose; Tmax: Time to reach peak or maximum concentration following administration |
Indication of spectral parameter measured, i.e. lambda (max) (max. absorbance), epsilon (max) and epsilon (295 nm) (molar extinction coefficients). |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:SPECTRUM> <i5:set> <i5:PHRASEOTHER_PARAMETER> <i5:PARAMETER> |
|
SE05.01.04.0761 |
Parameter [no
label] |
|
|
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:SPECTRUM> <i5:set> <i5:PHRASEOTHER_PARAMETER> <i5:PARAMETER_TXT> |
|
|
SE05.01.04.0770 |
Value [Value] |
|
|
Enter numeric value. |
Numeric value of the spectral parameter indicated in preceding subfield. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:SPECTRUM> <i5:set> <i5:VALUEUNIT_VALUE> <i5:VALUE> |
|
SE05.01.04.0780 |
Unit of spectral parameter [Spectrum
of substance] |
|
Picklist Values: nm
|| m || L/(mol cm) || m²/mol || 1/cm dm³ 1/mol || other: |
Select unit from drop-down list depending on the spectral parameter selected. E.g. use 'nm' for 'max lambda' or 'L/(mol cm)' or other appropriate unit for 'max epsilon'. If the unit is not listed, select 'other:' and specify. |
Unit of spectral parameter. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:SPECTRUM> <i5:set> <i5:VALUEUNIT_VALUE> <i5:UNIT> |
|
SE05.01.04.0781 |
Unit of spectral parameter [no
label] |
|
|
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:SPECTRUM> <i5:set> <i5:VALUEUNIT_VALUE> <i5:UNIT_TXT> |
|
|
SE05.01.04.0790 |
Remarks [Remarks] |
|
|
Enter any remarks related to the recorded value as appropriate. |
Remarks on spectral parameter. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:SPECTRUM> <i5:set> <i5:REM> <i5:REM> |
|
SE05.01.04.0799 |
% Degradation of test substance [%
Degradation of test substance] |
|
|
Specify percentage of degradation or range and sampling time. Copy this block of fields for recording results at different test conditions. |
Heading of field block '% Degradation of test substance'. |
|
|
SE05.01.04.0800 |
% degradation [%Degr.] |
|
Picklist Values: >
|| >= || ca. |
Enter a numeric value or a range of numeric values according to following conventions: (i) In the first numeric field, enter a single value (Qualifier subfield left blank) or a value if preceded by '>', '>=' or 'ca.' (e.g. '20', 'ca. 20', '>20'). (ii) In the second numeric field, enter a single value if preceded by '<' or '<='. (iii) Use both numeric fields and, as required, the lower and upper qualifier field to enter a range of numeric values (e.g. '2 - 8' or '>2 <8'). |
Percentage of degradation of test substance: Lower qualifier field providing a list with following operators: >, >=, and ca. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:DEGRAD> <i5:set> <i5:PRECISION_LOQUALIFIER> <i5:LOQUALIFIER> |
|
SE05.01.04.0810 |
% degradation [no
label] |
|
|
|
Percentage of degradation of test substance: Lower numeric field for entering a numeric value preceded either by no operator, '>', '>=' or 'ca.' (e.g. '20', '>20', '>=20', '20') |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:DEGRAD> <i5:set> <i5:PRECISION_LOQUALIFIER> <i5:LOVALUE> |
|
SE05.01.04.0820 |
% degradation [no
label] |
|
Picklist Values: <
|| <= || ca. |
|
Percentage of degradation of test substance: Upper qualifier field providing a list with following operators: <, <=, and ca. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:DEGRAD> <i5:set> <i5:PRECISION_LOQUALIFIER> <i5:UPQUALIFIER> |
|
SE05.01.04.0830 |
% degradation [no
label] |
|
|
|
Percentage of degradation of test substance: Upper numeric field for entering a numeric value only if either a lower value is already entered to specify a numeric range or if the numeric value is preceded by either operator '<' or '<='. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:DEGRAD> <i5:set> <i5:PRECISION_LOQUALIFIER> <i5:UPVALUE> |
|
SE05.01.04.0840 |
St. dev. [St.
dev.] |
|
|
Enter numeric value. |
Standard deviation of percentage of degradation of test substance. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:DEGRAD> <i5:set> <i5:STDEV> <i5:STDEV> |
|
SE05.01.04.0850 |
Sampling time [Sampling
time] |
|
|
Enter numeric value. |
Sampling time |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:DEGRAD> <i5:set> <i5:VALUEUNIT_TIMEPOINT_VALUE> <i5:TIMEPOINT_VALUE> |
|
SE05.01.04.0860 |
Unit sampling time [%
Degradation of test substance] |
|
Picklist Values: min
|| h || d || wk || mo || yr |
Select from drop-down list. |
Unit of time. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:DEGRAD> <i5:set> <i5:VALUEUNIT_TIMEPOINT_VALUE> <i5:TIMEPOINT_UNIT> |
|
SE05.01.04.0870 |
Test condition [Test
condition] |
|
|
If results at different test conditions are reported, specify test condition (e.g. different temperatures). Otherwise leave this subfield empty. |
Brief description of test run if results are given for different test runs. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:DEGRAD> <i5:set> <i5:TEST_CONDITION> <i5:TEST_CONDITION> |
|
SE05.01.04.0880 |
Quantum yield [Quantum
yield (for direct photolysis)] |
|
|
Give the reaction quantum yield of the test substance (values between 0 and 1). |
The reaction efficiency as calculated from the experimental measurements derived from a direct photolysis study. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:QUANTUM_YIELD> <i5:set> <i5:NUMBER_POS_BELOW> <i5:NUMBER_POS_BELOW> |
|
SE05.01.04.0889 |
Dissipation half-life of parent compound [Dissipation
half-life of parent compound] |
|
|
Provide the half-life / DT50 or range as appropriate. Copy this block of fields for recording results at different test conditions. |
Heading of field block 'Kinetics and dissipation half-life of parent compound' |
|
|
SE05.01.04.0890 |
Half-life / DT50 [DT50] |
|
Picklist Values: >
|| >= || ca. |
Enter a numeric value or a range of numeric values according to following conventions: (i) In the first numeric field, enter a single value (Qualifier subfield left blank) or a value if preceded by '>', '>=' or 'ca.' (e.g. '20', 'ca. 20', '>20'). (ii) In the second numeric field, enter a single value if preceded by '<' or '<='. (iii) Use both numeric fields and, as required, the lower and upper qualifier field to enter a range of numeric values (e.g. '2 - 8' or '>2 <8'). |
First order/other half life: Lower qualifier field providing a list with following operators: >, >=, and ca. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:DISSIP> <i5:set> <i5:PRECISION_HALFLIFE_LOQUALIFIER> <i5:HALFLIFE_LOQUALIFIER> |
|
SE05.01.04.0900 |
Half-life / DT50 [no
label] |
|
|
|
First order/other half life: Lower numeric field for entering a numeric value preceded either by no operator, '>', '>=' or 'ca.' (e.g. '20', '>20', '>=20', '20') |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:DISSIP> <i5:set> <i5:PRECISION_HALFLIFE_LOQUALIFIER> <i5:HALFLIFE_LOVALUE> |
|
SE05.01.04.0910 |
Half-life / DT50 [no
label] |
|
Picklist Values: <
|| <= || ca. |
|
First order/other half life: Upper qualifier field providing a list with following operators: <, <=, and ca. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:DISSIP> <i5:set> <i5:PRECISION_HALFLIFE_LOQUALIFIER> <i5:HALFLIFE_UPQUALIFIER> |
|
SE05.01.04.0920 |
Half-life / DT50 [no
label] |
|
|
|
First order/other half life: Upper numeric field for entering a numeric value only if either a lower value is already entered to specify a numeric range or if the numeric value is preceded by either operator '<' or '<='. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:DISSIP> <i5:set> <i5:PRECISION_HALFLIFE_LOQUALIFIER> <i5:HALFLIFE_UPVALUE> |
|
SE05.01.04.0930 |
Unit [Dissipation
half-life of parent compound] |
|
Picklist Values: min
|| h || d || wk || mo || yr |
Select from drop-down list. |
Unit of half life. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:DISSIP> <i5:set> <i5:PRECISION_HALFLIFE_LOQUALIFIER> <i5:HALFLIFE_UNIT> |
|
SE05.01.04.0940 |
Test condition [Test
condition] |
|
|
If results at different test conditions are reported, specify test condition (e.g. different temperatures). Otherwise leave this subfield empty. |
Brief description of test condition if results are given for different test runs. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:DISSIP> <i5:set> <i5:TEST_CONDITION> <i5:TEST_CONDITION> |
|
SE05.01.04.0950 |
Transformation products [Transformation
products] |
|
Picklist Values: no
|| not measured || yes || no data |
Indicate whether transformation products occurred. If yes, provide the identified transformation products in following block of fields. Any further details can be entered in field 'Any other information on results incl. tables'. |
Indicator that transformation products occurred or not. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:TRANSF_PRODUCTS_INDICATOR> <i5:set> <i5:LIST_BELOW_SEL> <i5:LIST_BELOW_SEL> |
|
SE05.01.04.0959 |
Identity of transformation products [Identity
of degradation products] |
|
|
Indicate the identity of the transformation products using an appropriate identifier, e.g. CAS number, CAS name, IUPAC name. Copy this block of fields for each relevant substance. Any further details on transformation products can be provided in field 'Any other information on materials and methods incl. tables'. |
Heading of field block 'Identity of degradation / transformation products'. |
|
|
SE05.01.04.0960 |
No. [No.] |
|
Picklist Values: #1
|| #2 || #3 || #4 || #5 || #6 || #7 || #8 || #9 || #10 || #11 || #12 || #13
|| #14 || #15 || #16 || #17 || #18 || #19 || #20 |
For easier distinction select a consecutive number for each transformation product from drop-down list if more than one transformation product is entered. If the same substance is identified by more than one identifiers (e.g. by CAS name and Common name), make sure that the same number is allocated to these entries. |
Indication of a consecutive number 1-n used to distinguish the degradation / transformation products. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:TRANSF_PRODUCTS_ID> <i5:set> <i5:NO> <i5:NO> |
|
SE05.01.04.0970 |
Identifier [Identifier] |
|
Picklist Values: CAS
name || CAS number || Common name || EC name || EC number || IUPAC name ||
TSCA name || other: |
Select an appropriate identifier from drop-down list, e.g. 'CAS number'. Use 'Other:' if identity according to a standard identifier is not known. Specify if another identifier is provided (e.g. 'Other: xxx'). |
Indicator specifying the type of chemical identifier, e.g. CAS name. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:TRANSF_PRODUCTS_ID> <i5:set> <i5:PHRASEOTHER_IDENTIFIER> <i5:IDENTIFIER> |
|
SE05.01.04.0971 |
Identifier [no
label] |
|
|
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:TRANSF_PRODUCTS_ID> <i5:set> <i5:PHRASEOTHER_IDENTIFIER> <i5:IDENTIFIER_TXT> |
|
|
SE05.01.04.0980 |
Identity [Identity] |
|
|
Select the corresponding substance identity from drop-down list or enter manually if the identity is not available from the list or if no list is provided for the type of identifier selected. |
Identity of the chemical substance. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:TRANSF_PRODUCTS_ID> <i5:set> <i5:ID> <i5:ID> |
|
SE05.01.04.0990 |
Details on results [Details
on results] |
|
REMARKS: Available predefined table(s) are displayed below, after this template. See also List of Predefined Tables in Annex 2. Freetext Templates: HALF-LIFE TEST CONDITIONS - Moisture, temperature, and other experimental conditions maintained throughout the study: Yes/No - Anomalies or problems encountered (if yes): MAJOR TRANSFORMATION PRODUCTS (distinguish between dark and irradiated samples) - Range of maximum concentrations in % of the applied amount and day(s) of incubation when observed: - Range of maximum concentrations in % of the applied amount at end of study period: on the - the and -th day of incubation, respectively. At the end of the study period, the corresponding concentrations were - and -- % of the applied amount, respectively. MINOR TRANSFORMATION PRODUCTS (distinguish between dark and irradiated samples) - Range of maximum concentrations in % of the applied amount and day(s) of incubation when observed: - Range of maximum concentrations in % of the applied amount at end of study period: TOTAL UNIDENTIFIED RADIOACTIVITY (RANGE) OF APPLIED AMOUNT (distinguish between dark and irradiated samples): EXTRACTABLE RESIDUES(distinguish between dark and irradiated samples) - % of applied amount at day 0: - % of applied amount at end of study period: NON-EXTRACTABLE RESIDUES(distinguish between dark and irradiated samples) - % of applied amount at day 0: - % of applied amount at end of study period: MINERALISATION (distinguish between dark and irradiated samples) - % of applied radioactivity present as CO2 at end of study: VOLATILIZATION (distinguish between dark and irradiated samples) - % of the applied radioactivity present as volatile organics at end of study: TRANSFORMATION PATHWAY - Description of biotransformation pathway: - Figure attached: Yes/No SUPPLEMENTARY EXPERIMENT (if any): RESULTS: |
Indicate any further relevant details of test results. Use freetext template and delete/add elements as appropriate. As appropriate or requested by the regulatory programme include table(s) with raw data in the rich text field 'Any other information on results incl. tables'. Upload predefined table(s) if any or adapt table(s) from study report. Use table numbers in the sequence in which you refer to them in the text (e.g. '... see Table 1'). Explanations on freetext prompts: TEST CONDITIONS: If the test conditions were not maintained, describe any anomalies or problems encountered. HALF-LIFE: Include a table with detailed results for dark and irradiated samples including Regression equation, r²' and DT90 if available. MAJOR / MINOR TRANSFORMATION PRODUCTS: Indicate concentration ranges of the transformation products specified in the defined field 'Identity of transformation products' or specify if no major transformation products were detected. Tabulate comprehensive data and refer to respective table no. (use predefined table if any) or other appropriate table. Distinguish between dark and irradiated samples; compare the transformation products formed in the dark and irradiated samples, and identify and quantify the products that are formed by phototransformation only. As appropriate attach Figure showing the pathway of phototransformation of the test substance. SUPPLEMENTARY EXPERIMENT: Briefly describe the results of the supplementary experiment, if any. |
Details on results |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:RESULTS_DETAILS> <i5:set> <i5:FREETEXT_BELOW> <i5:FREETEXT_BELOW> |
|
SE05.01.04.1000 |
Results with reference substance [Results
with reference substance] |
|
|
Indicate whether the results with the reference substance(s) are valid. |
Indication whether the results with the reference substance(s) are valid. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:RS_REF_SUBSTANCE> <i5:set> <i5:TEXT_INT> <i5:TEXT_INT> |
|
SE05.01.04.1010 |
Any other information on results incl. tables [Any
other information on results incl. tables] |
|
|
In this field, you can enter any other remarks on results. You can also open a rich text editor and create formatted text and tables or insert and edit any excerpt from a word processing or spreadsheet document, provided it was converted to the HTML format. Note: Both the 'Materials and methods' section and 'Results' section. In addition the fields 'Overall remarks' and 'Executive summary' allow rich text entry. |
Rich text editor field for creating formatted text and tables or inserting and editing any excerpt from a word processing or spreadsheet document, provided it was converted to the HTML format. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:REM_RS> <i5:set> <i5:RICHTEXT_BELOW> <i5:RICHTEXT_BELOW> |
|
SE05.01.04.1015 |
OVERALL REMARKS, ATTACHMENTS [Overall
remarks, attachments] |
|
|
|
Main heading under which 'Overall remarks, attachments' fields are subsumed. |
|
|
SE05.01.04.1020 |
Remarks on results including tables and figures [Remarks
on results including tables and figures] |
|
|
In this field, you can enter any overall remarks or transfer free text from other databases. You can also open a rich text editor and create formatted text and tables or insert and edit any excerpt from a word processing or spreadsheet document, provided it was converted to the HTML format. Note: One rich text editor field each is provided for the MATERIALS AND METHODS and RESULTS section. In addition the fields 'Overall remarks' and 'Executive summary' allow rich text entry. |
Rich text editor field for creating formatted text and tables or inserting and editing any excerpt from a word processing or spreadsheet document, provided it was converted to the HTML format. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:REM_ANYOTHER> <i5:set> <i5:RICHTEXT_BELOW> <i5:RICHTEXT_BELOW> |
|
SE05.01.04.1029 |
Attached background material [Attached
background material] |
|
|
Attach any background document that cannot be inserted in any rich text editor field, particularly image files (e.g. an image of a structural formula). Copy this block of fields for attaching more than one file. |
Heading of field block 'Attached document'. |
|
|
SE05.01.04.1030 |
Attached document [Attached
document] |
|
|
Upload file by clicking the upload icon. As appropriate, enter any additional information, e.g. language. The file name is displayed after uploading the document. |
File name of document uploaded, i.e. attached. No restriction as to file type. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:AD> <i5:set> <i5:DOC> <i5:DOC> |
|
SE05.01.04.1040 |
Remarks [Remarks] |
|
|
As appropriate, include remarks, e.g. a short description of the content of the attached document if the file name is not self-explanatory. |
Remarks on attached document. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:AD> <i5:set> <i5:REM> <i5:REM> |
|
SE05.01.04.1049 |
Attached full study report [Attached
full study report] |
|
|
If required, an electronic copy of the full study report can be attached as WORD, pdf or other document type, which will not be integrated in any report, but must be handled as separate files. Note: In the export administration you can indicate whether the attached files should be included in the data export or not. |
Attached full study report |
|
|
SE05.01.04.1050 |
Attached full study report [Attached
full study report] |
|
|
Upload file by clicking the upload icon. As appropriate, enter any additional information, e.g. language. The file name is displayed after uploading the document. |
Attached full study report |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:AD_STUDYREPORT> <i5:set> <i5:ATTACHMENT_BELOW> <i5:ATTACHMENT_BELOW> |
|
SE05.01.04.1052 |
Illustration (picture/graph) [Illustration
(picture/graph)] |
|
|
Upload file by clicking the upload icon. As appropriate, enter any additional information, e.g. language. The file name is displayed after uploading the document. |
Illustration (picture/graph) |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:PG_ILLUSTRATION> <i5:set> <i5:PIC_BELOW> <i5:PIC_BELOW> |
|
SE05.01.04.1055 |
APPLICANT'S SUMMARY AND CONCLUSION [Applicant's
summary and conclusion] |
|
|
|
Main heading under which generic 'Applicant's summary and conclusion' fields are subsumed. |
|
|
SE05.01.04.1060 |
Validity criteria fulfilled [Validity
criteria fulfilled] |
|
Picklist Values: yes
|| no || no data || not applicable |
Indicate whether validity criteria given by test guideline have been fulfilled or not. Use supplementary remarks field for indicating the criteria and entering remarks. Clearly indicate if the criteria used are not consistent with those given by the test guideline. If so, give justification in field 'Rationale for reliability incl. deficiences' as to why this study summary is considered reliable. |
Indication of validity criteria and whether they have been fulfilled or not. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:VALIDITY_CRIT_SUBM> <i5:set> <i5:PHRASEOTHER_LIST_SEL_FIX> <i5:LIST_SEL_FIX> |
|
SE05.01.04.1061 |
Validity criteria fulfilled [no
label] |
|
|
|
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:VALIDITY_CRIT_SUBM> <i5:set> <i5:PHRASEOTHER_LIST_SEL_FIX> <i5:LIST_SEL_FIX_TXT> |
|
|
SE05.01.04.1070 |
Conclusions [Conclusions] |
|
|
Enter any conclusions if applicable. |
Any conclusions either as adapted from the study report / publication or indicated by the submitter. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:APPL_CL> <i5:set> <i5:TEXTAREA_BELOW> <i5:TEXTAREA_BELOW> |
|
SE05.01.04.1080 |
Executive summary [Executive
summary] |
|
REMARKS: Available predefined executive summary is shown below, at the end of this template. See also List of Predefined Executive Summaries in Annex 3. |
If required by the respective national/regional programme, briefly summarise the relevant aspects of the study including the conclusions reached. If a specific format is prescribed, upload the respective freetext template if available from the drop-down list or copy it from the corresponding document. Consult the programme-specific guidance (e.g. OECD HPVC, Pesticides NAFTA or EU REACH) thereof. |
Executive summary in which the relevant aspects of the study including the conclusions reached are briefly summarised. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:APPL_EXEC_SUM> <i5:set> <i5:RICHTEXT_BELOW> <i5:RICHTEXT_BELOW> |
|
SE05.01.04.1090 |
Cross-reference to other study [Cross-reference
to other study] |
|
|
A Cross-reference to other study or other studies can be included which are considered relevant in the interpretation of the test results, e.g. for supporting the conclusion that an effect observed was not substance-related. Indicate the respective chapter(s) and record ID(s) and enter relevant explanatory text. Such cross-references may be useful if it is considered relevant to discuss other results at the summary level of a single study. It should be noted that the overall appraisal of results from different studies is normally done in the hazard or risk assessment. Note that any such cross-reference may become useless if a record is either printed or exchanged on its own. |
A cross-reference to another study or other studies including explanatory text on why other results are relevant in the interpretation of the results of a given study, e.g. for supporting any conclusions. |
<i5:EndpointStudyRecord> <i5:scientificPart> <i5:TO_PHOTOTRANS_SOIL> <i5:CROSSREF_OTHER_STUDY> <i5:set> <i5:TEXT_BELOW> <i5:TEXT_BELOW> |