OECD Template #24: Phototransformation in air (Version 3-June 2012)

The following table gives a detailed description of the type of information prompted for by the data entry fields. Elements provided to guide the user include predefined picklist phrases, freetext templates and context-sensitive help texts. In addition, technical elements are provided, i.e. field and data types, explanations for use in Data Element Dictionary (DED) and the xml schema. The conventions used are explained in part 'Introduction and Format of OECD Harmonised Templates'.

Field number

Field description

[Field label]

  1. Field type
  2. Data type
  3. Group ID
  4. Max occ.
  5. Detail level
  6. Picklist code

Remarks, Picklist, Freetext template

Help text

Explanation for use in Data Element Dictionary (DED)

XML Schema

 

ADMINISTRATIVE DATA

 

REMARKS:

Under this main heading, fields are subsumed for identifying the purpose of the record (e.g., 'key study'), the type of result (e.g., 'experimental study'), data waiving indication (if any), reliability indication, and flags for indicating the regulatory purpose envisaged and/or any confidentiality restrictions. This kind of data characterise the relevance of a study summary and may therefore be displayed on top of each template. For detailed guidance, refer to Administrative data.

 

 

 

SE05.01.01.0215

DATA SOURCE

[Data source]

  1. HEAD-1
  2. Heading level 1
  3. [N/A]
  4. 1
  5. 1
  6. [N/A]

 

 

Main heading under which generic 'Data source' fields are subsumed.

 

SE05.01.01.0219

Reference

[Reference]

  1. HEAD BLOCK
  2. Block label
  3. g158
  4. 10
  5. 1
  6. [N/A]

 

Indicate the bibliographic reference of the study report or publication the study summary is based on. Always enter the primary reference in the first block of fields (i.e. Sort no. = 1), if there are more than one reference to be cited. Copy this block of fields for specifying any other references related to this record (e.g. report of a preliminary study or other documentation). If results of a study report have been published, indicate the full citation of that publication(s) in addition to the reference of the original study.

Heading of field block 'Reference'

 

SE05.01.01.0220

Reference type

[Reference type]

  1. LIST-OPEN
  2. STRING/255
  3. g158
  4. 1
  5. 1
  6. Z31

Picklist Values:

study report || other company data || publication || review article or handbook || secondary source || grey literature || other:

Indicate the type of reference, e.g. 'Study report' or 'Publication'. Select 'Other company data' to characterise any unpublished information from a company other than a study report. Select 'Grey literature' for any other unpublished information or 'other:' and specify.

Indicator specifying the type of reference, e.g. 'Study report' or 'Publication'.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:REFERENCE>

<i5:set>

<i5:PHRASEOTHER_REFERENCE_TYPE>

<i5:REFERENCE_TYPE>

SE05.01.01.0221

Reference type

[no label]

  1. OTHERTEXT
  2. STRING/255
  3. g158
  4. 1
  5. 1
  6. [N/A]

 

 

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:REFERENCE>

<i5:set>

<i5:PHRASEOTHER_REFERENCE_TYPE>

<i5:REFERENCE_TYPE_TXT>

SE05.01.01.0230

Author(s) (or transferred reference)

[Author]

  1. TEXT
  2. STRING/2000
  3. g158
  4. 1
  5. 1
  6. [N/A]

 

For ease of sorting and searchability use following convention: Surname, Initial (Example 1: White D, Ruehl KJ, Borman SA & Little J. Example 2: Hartley M & Murray W (avoid unnecessary full-stops, commas)). If no individuals are cited as authors, enter name of company or organisation or 'Anon.' as appropriate.

Note that the complete bibliographic reference may appear in this field after migration of unstructured data from existing databases.

Name(s) of author(s) of the study report or publication.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:REFERENCE>

<i5:set>

<i5:REFERENCE_AUTHOR>

<i5:REFERENCE_AUTHOR>

SE05.01.01.0240

Year

[Year]

  1. YEAR
  2. NUMBER/4/###0
  3. g158
  4. 1
  5. 1
  6. [N/A]

 

Enter year of study report or publication. For a study report this field should be completed to include it in any searches, regardless of whether the complete date is given in field 'Report date'.

Year of the study report or publication.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:REFERENCE>

<i5:set>

<i5:REFERENCE_YEAR>

<i5:REFERENCE_YEAR>

SE05.01.01.0250

Title

[Title]

  1. TEXT
  2. STRING/255
  3. g158
  4. 1
  5. 1
  6. [N/A]

 

Include the title of the report. For publications, include the title of the article of a journal or article/chapter of a book (e.g. handbook).

Title of a study report or title of published article of journal or book (e.g. handbook).

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:REFERENCE>

<i5:set>

<i5:REFERENCE_TITLE>

<i5:REFERENCE_TITLE>

SE05.01.01.0260

Bibliographic source

[Bibliographic source]

  1. TEXT
  2. STRING/255
  3. g158
  4. 1
  5. 1
  6. [N/A]

 

Not relevant for any study report. For publications or any other literature source (grey literature) specify the following type of information: (i) Title of scientific journal or book (e.g. if handbook); (ii) Volume of journal; (iii) Editor, publisher, place of publication for books or articles in books; (iv) Pagination.

Example 1 (journal): J. Agric. Food Chem. 38: 215-227

Example 2 (handbook): In: Lyman WJ (ed.) Handbook of chemical property estimation methods. Environmental behavior of organic compounds. McGraw-Hill Book Company 15.1-15.34, New York.

Bibliographic source of the study report or publication.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:REFERENCE>

<i5:set>

<i5:REFERENCE_SOURCE>

<i5:REFERENCE_SOURCE>

SE05.01.01.0270

Testing laboratory

[Testing laboratory]

  1. TEXT
  2. STRING/255
  3. g158
  4. 1
  5. 1
  6. [N/A]

 

Either manually enter the name of the testing laboratory or select it from the picklist. In either case, editing is possible.

Name of the testing laboratory.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:REFERENCE>

<i5:set>

<i5:REFERENCE_TESTLAB>

<i5:REFERENCE_TESTLAB>

SE05.01.01.0280

Report no.

[Report no.]

  1. TEXT
  2. STRING/255
  3. g158
  4. 1
  5. 1
  6. [N/A]

 

Specify the report number allocated by the testing laboratory. Note that any company-specific study number should be included in the respective field.

Report number allocated by the testing laboratory.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:REFERENCE>

<i5:set>

<i5:REFERENCE_REPORT_NO>

<i5:REFERENCE_REPORT_NO>

SE05.01.01.0290

Owner company

[Owner company]

  1. TEXT
  2. STRING/255
  3. g158
  4. 1
  5. 1
  6. [N/A]

 

Either manually enter the identity of the company who owns the data or select it from the picklist. In either case, editing is possible.

Identity of the sponsor company who owns the study report.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:REFERENCE>

<i5:set>

<i5:REFERENCE_COMPANY_ID>

<i5:REFERENCE_COMPANY_ID>

SE05.01.01.0300

Company study no.

[Company study no.]

  1. TEXT
  2. STRING/255
  3. g158
  4. 1
  5. 1
  6. [N/A]

 

Specify any company study no. if there is such a number and if it is different from the report no. of the testing laboratory. Otherwise leave field empty.

Company-specific study number.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:REFERENCE>

<i5:set>

<i5:REFERENCE_COMPANY_STUDY_NO>

<i5:REFERENCE_COMPANY_STUDY_NO>

SE05.01.01.0310

Report date

[Report date]

  1. DATE
  2. DATE/255
  3. g158
  4. 1
  5. 1
  6. [N/A]

 

Specify the complete date of the study report, e.g. '2005-05-12' for 12 May 2005. Note that subfield 'Year' should be completed in any case for sorting and searching purposes.

Complete date of the study report.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:REFERENCE>

<i5:set>

<i5:REFERENCE_REPORT_DATE>

<i5:REFERENCE_REPORT_DATE>

SE05.01.01.0320

Data access

[Data access]

  1. LIST-OPEN
  2. STRING/255
  3. [N/A]
  4. 1
  5. 1
  6. Z03

Picklist Values:

data submitter is data owner || data submitter has Letter of Access || data no longer protected || data published || not applicable || other:

Select appropriate indication for data access. Enter 'Not applicable' if the summary consists of information that is commonly accessible such as guidance on safe use.

Indication for data access.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:DATA_ACCESS>

<i5:set>

<i5:PHRASEOTHER_LIST_POP>

<i5:LIST_POP>

SE05.01.01.0321

Data access

[no label]

  1. OTHERTEXT
  2. STRING/255
  3. [N/A]
  4. 1
  5. 1
  6. [N/A]

 

 

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:DATA_ACCESS>

<i5:set>

<i5:PHRASEOTHER_LIST_POP>

<i5:LIST_POP_TXT>

SE05.01.01.0330

Data protection claimed

[Data protection claimed]

  1. LIST-CLOSED-SUP
  2. STRING/255
  3. [N/A]
  4. 1
  5. 1
  6. Z30

Picklist Values:

yes || yes, but willing to share || yes, but not willing to share

Indicate as appropriate. Note: 'yes' should be selected only if 'Data submitter is data owner' or 'Data submitter has Letter of Access'. Options 'yes, but willing to share' or 'yes, but not willing to share' may be relevant for specific regulatory programmes where the submitter is requested to indicate whether he is willing to share studies (e.g. with vertebrates).

In the supplementary remarks field, include an explanation as appropriate, i.e. justification for denial of sharing the corresponding study or refer to a document attached that provides justification (e.g. 'for justification see attached document X')

Indication if data protection is claimed by the submitter who has to be data owner or have letter of access.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:DATA_PROT_CLAIM>

<i5:set>

<i5:PHRASEOTHER_LIST_POP_FIX>

<i5:LIST_POP_FIX>

SE05.01.01.0331

Data protection claimed

[no label]

  1. SUP-TEXT
  2. STRING/255
  3. [N/A]
  4. 1
  5. 1
  6. [N/A]

 

 

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:DATA_PROT_CLAIM>

<i5:set>

<i5:PHRASEOTHER_LIST_POP_FIX>

<i5:LIST_POP_FIX_TXT>

SE05.01.01.0340

Cross-reference to same study

[Cross-reference to same study]

  1. TEXTAREA
  2. STRING/2000
  3. [N/A]
  4. 1
  5. 1
  6. [N/A]

 

A cross-reference can be included to indicate that the same study is recorded in another record. Indicate the respective chapter and record ID and enter relevant explanatory text. This may be useful if specific endpoints of a given study are described in another chapter (e.g. results on reproduction toxicity in case of a combined repeated dose / reproduction toxicity study) or if more than one experiment is described by the same study report, but included in separate records.

Check with the relevant guidance document whether all the methodology details must be repeated or whether a cross-reference to the same study in another chapter may suffice.

Note that any such cross-reference may become useless if a record is either printed or exchanged on its own.

Indication that the same study is described in another study summary / chapter of the data set.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:CROSSREF_SAMESTUDY>

<i5:set>

<i5:TEXT_BELOW>

<i5:TEXT_BELOW>

SE05.01.01.0345

MATERIALS AND METHODS

[Materials and methods]

  1. HEAD-1
  2. Heading level 1
  3. [N/A]
  4. 1
  5. 1
  6. [N/A]

 

 

Main heading under which generic 'Materials and methods' fields are subsumed.

 

SE05.01.01.0349

Test guideline

[Test guideline]

  1. HEAD BLOCK
  2. Block label
  3. g159
  4. 5
  5. 1
  6. [N/A]

 

Indicate according to which test guideline the study was conducted. If no test guideline was explicitly followed, but the methodology used is equivalent or similar to a specific guideline, you can indicate so in the 'Qualifier' subfield preceding the field 'Guideline'.

Copy this block of fields for specifying more than one guideline (e.g. US EPA in addition to OECD guideline).

Heading of field block 'Guideline'

 

SE05.01.01.0350

Qualifier

[Qualifier]

  1. LIST-CLOSED
  2. STRING/255
  3. g159
  4. 1
  5. 1
  6. Z06

Picklist Values:

according to || equivalent or similar to || no guideline followed || no guideline available || no guideline required

Select appropriate qualifier, i.e.

- 'according to' (if a given test guideline was followed);

- 'equivalent or similar to' (if no test guideline was explicitly followed, but the methodology is equivalent or similar to a specific guideline);

- 'no guideline followed' (if none of above qualifiers apply. If so, fill in field 'Principles of method if other than guideline');

- 'no guideline available' (if so, fill in field 'Principles of method if other than guideline').

- 'no guideline required' (if so, fill in field 'Principles of method if other than guideline').

An indicator signifying how strict the guideline given in the subsequent field 'Guideline' was followed or whether no guideline was used or available/required.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:GUIDELINE>

<i5:set>

<i5:QUALIFIER>

<i5:QUALIFIER>

SE05.01.01.0360

Guideline

[Guideline]

  1. LIST-OPEN-SUP
  2. STRING/255
  3. g159
  4. 1
  5. 1
  6. F02-1

Picklist Values:

OECD Guideline draft (Photochemical Oxidative Degradation in the Atmosphere) || EPA OPPTS 835.2310 (Maximum Direct Photolysis Rate in Air from UV/Visible Spectroscopy) || EPA OTS 796.3800 (Maximum Direct Photolysis Rate in Air from UV/Visible Spectroscopy) || EPA Guideline Subdivision N 161-4 (Photodegradation Studies in Air) || other guideline:

Select the applicable test guideline, e.g. 'OECD Guideline xxx'. If the test guideline used is not listed, choose 'other guideline:' and specify the test guideline in the related text field.

In this text field, you can also enter any remarks as applicable, particularly:

- To include any other title of the test guideline draft used, a subtitle, another version or update number and the year of update (For instance, different titles and/or numbers may exist for a given EU test guideline.);

- To indicate if a the study was performed prior to the adoption of the test guideline specified;

- To indicate if the methodology used was based on an extension of the test guideline specified.

The name of the guideline followed in performing the study or to which the method used can be compared. Also indication if no guideline was used, available or required. In supplementary remarks field indication of guideline version or title if deviating from the picklist value, or of additional test guidelines cited.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:GUIDELINE>

<i5:set>

<i5:PHRASEOTHER_GUIDELINE>

<i5:GUIDELINE>

SE05.01.01.0361

Guideline

[no label]

  1. SUP-TEXT
  2. STRING/255
  3. g159
  4. 1
  5. 1
  6. [N/A]

 

 

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:GUIDELINE>

<i5:set>

<i5:PHRASEOTHER_GUIDELINE>

<i5:GUIDELINE_TXT>

SE05.01.01.0370

Deviations from guideline

[Deviations]

  1. LIST-CLOSED-SUP
  2. STRING/255
  3. g159
  4. 1
  5. 1
  6. Z08

Picklist Values:

yes || no || no data || not applicable

For robust study summaries or as requested by the regulatory programme, indicate if there are any deviations from the test guideline specified. If 'yes' is selected, only briefly state relevant deviations in the supplementary remarks field (e.g. 'other species used'); details should be described in the respective fields of the section MATERIALS AND METHODS.

Indication that a study contains deviations from the standard test protocol.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:GUIDELINE>

<i5:set>

<i5:PHRASEOTHER_DEVIATION>

<i5:DEVIATION>

SE05.01.01.0371

Deviations from guideline

[no label]

  1. SUP-TEXT
  2. STRING/255
  3. g159
  4. 1
  5. 1
  6. [N/A]

 

 

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:GUIDELINE>

<i5:set>

<i5:PHRASEOTHER_DEVIATION>

<i5:DEVIATION_TXT>

SE05.01.01.0380

Principles of method if other than guideline

[Principles of method if other than guideline]

  1. TEXTAREA
  2. STRING/32768
  3. [N/A]
  4. 1
  5. 1
  6. [N/A]

 

If no guideline was followed, include a description of the principles of the test protocol or estimated method used in the study. Details should be entered in appropriate distinct fields of section MATERIALS AND METHODS if available. Also provide a justification for using this method if appropriate.

If an estimation method was used (to be indicated in field 'Study result type') state the equation(s) and/or computer software or other methods applied to calculate the value(s).

Description of the test protocol or estimated method used in the study, if other than a guideline, and justification for using this method if appropriate.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:METHOD_NOGUIDELINE>

<i5:set>

<i5:TEXTAREA_BELOW>

<i5:TEXTAREA_BELOW>

SE05.01.01.0390

GLP compliance

[GLP compliance]

  1. LIST-CLOSED-SUP
  2. STRING/255
  3. [N/A]
  4. 1
  5. 1
  6. Z40

Picklist Values:

yes (incl. certificate) || yes || no || no data

Indicate whether the study was conducted following Good Laboratory Practice or not. Select 'yes (incl. certificate)' if a GLP certificate of a test facility is available. Select 'yes' if a GLP compliance statement is available, but no information on a GLP certificate. You can give an explanation in the supplementary remarks field, e.g. for explaining why GLP was not complied with or for specifying which (national) GLP was followed.

Indication whether a GLP certificate or compliance statement is available.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:GLP_COMPLIANCE_STATEMENT>

<i5:set>

<i5:PHRASEOTHER_LIST_SEL_FIX>

<i5:LIST_SEL_FIX>

SE05.01.01.0391

GLP compliance

[no label]

  1. SUP-TEXT
  2. STRING/255
  3. [N/A]
  4. 1
  5. 1
  6. [N/A]

 

 

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:GLP_COMPLIANCE_STATEMENT>

<i5:set>

<i5:PHRASEOTHER_LIST_SEL_FIX>

<i5:LIST_SEL_FIX_TXT>

SE05.01.01.0395

Test materials

[Test materials]

  1. HEAD-2
  2. Heading level 2
  3. [N/A]
  4. 1
  5. 1
  6. [N/A]

 

 

Subheading of section 'Test materials'

 

SE05.01.01.0400

Test material equivalent to submission substance identity

[Identity of test material same as for substance defined in section 1 (if not read-across)]

  1. LIST-CLOSED
  2. STRING/255
  3. [N/A]
  4. 1
  5. 1
  6. Z38

Picklist Values:

yes || no

Select 'yes' or 'no' from the drop-down list for indicating that the identity of the test material is the same or is not the same, respectively, as for substance defined in section 1 (General information). In addition, the identity of the test material should be specified in the subsequent block of fields 'Test material identity'.

NOTE: You cannot update this field, if a completed record is copied to another submission substance as reference. Therefore, in case of read-across the indication of 'yes' is not relevant.

Indicator showing whether the test material used is equivalent to the submission substance identity.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:TESTMAT_INDICATOR>

<i5:set>

<i5:LIST_BELOW_SEL>

<i5:LIST_BELOW_SEL>

SE05.01.01.0409

Test material identity

[Test material identity]

  1. HEAD BLOCK
  2. Block label
  3. g160
  4. 10
  5. 1
  6. [N/A]

 

Indicate the identity of the test material for one or more appropriate identifiers, e.g. CAS number, CAS name, IUPAC name. Copy this block of fields as appropriate.

NOTE: In order to avoid confusion on the test material identity it is highly recommended to enter at least one substance identifier, regardless of what has been entered in field 'Identity of test material same as for substance defined in section 1 (if not read-across)'.

Heading of field block 'Test material identity'

 

SE05.01.01.0410

Identifier

[Identifier]

  1. LIST-OPEN
  2. STRING/255
  3. g160
  4. 1
  5. 1
  6. Z39

Picklist Values:

CAS name || CAS number || Common name || EC name || EC number || IUPAC name || TSCA name || other:

Select an appropriate identifier from drop-down list, e.g. 'CAS number'. Use 'Other:' and specify, if identity according to a standard identifier is not known or if an additional chemical name or number is provided.

Indicator specifying the type of chemical identifier, e.g. CAS name.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:TESTMAT>

<i5:set>

<i5:PHRASEOTHER_IDENTIFIER>

<i5:IDENTIFIER>

SE05.01.01.0411

Identifier

[no label]

  1. OTHERTEXT
  2. STRING/255
  3. g160
  4. 1
  5. 1
  6. [N/A]

 

 

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:TESTMAT>

<i5:set>

<i5:PHRASEOTHER_IDENTIFIER>

<i5:IDENTIFIER_TXT>

SE05.01.01.0420

Identity

[Identity]

  1. TEXT
  2. STRING/2000
  3. g160
  4. 1
  5. 1
  6. [N/A]

 

Select the corresponding substance identity from drop-down list or enter manually if the identity is not available from the list or if no list is provided for the type of identifier selected.

Identity of the chemical substance used in the study or referred to in the record.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:TESTMAT>

<i5:set>

<i5:ID>

<i5:ID>

SE05.01.01.0425

Physical form

[Test material form]

  1. LIST-OPEN
  2. STRING/255
  3. [N/A]
  4. 1
  5. 1
  6. A101

Picklist Values:

aerosol || compact || crystalline || dispersion || fibre || filaments || flakes || liquified gas || nanomaterial || particulates || paste || pellets || powder || refrigerated liquid || suspension || viscous || other: || no data

Select the test material form from the drop-down list. If the form of the test chemical is not available in the list, select 'other:' and specify in the adjacent field. If the test material form is unknown, select 'no data'.

Form of the substance, i.e. powder, crystalline, compact, viscous, etc.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:TESTMAT_FORM>

<i5:set>

<i5:PHRASEOTHER_TESTMAT_FORM>

<i5:TESTMAT_FORM>

SE05.01.01.0426

Test material form

[no label]

  1. OTHERTEXT
  2. STRING/255
  3. [N/A]
  4. 1
  5. 1
  6. [N/A]

 

 

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:TESTMAT_FORM>

<i5:set>

<i5:PHRASEOTHER_TESTMAT_FORM>

<i5:TESTMAT_FORM_TXT>

SE05.01.01.0430

Details on test material

[Details on test material]

  1. TEXT-TEMPL
  2. STRING/32768
  3. [N/A]
  4. 1
  5. 1
  6. [N/A]

Freetext Templates:

- Name of test material (as cited in study report):

- Molecular formula (if other than submission substance):

- Molecular weight (if other than submission substance):

- Smiles notation (if other than submission substance):

- InChl (if other than submission substance):

- Structural formula attached as image file (if other than submission substance): see Fig.

- Substance type:

- Physical state:

- Analytical purity:

- Impurities (identity and concentrations):

- Composition of test material, percentage of components:

- Isomers composition:

- Purity test date:

- Lot/batch No.:

- Expiration date of the lot/batch:

- Radiochemical purity (if radiolabelling):

- Specific activity (if radiolabelling):

- Locations of the label (if radiolabelling):

- Expiration date of radiochemical substance (if radiolabelling):

- Stability under test conditions:

- Storage condition of test material:

- Other:

Use freetext template and delete/add elements as appropriate. Enter any details that could be relevant for evaluating this study summary or that are requested by the respective regulatory programme. Consult the programme-specific guidance (e.g. OECD HPVC, Pesticides NAFTA or EU REACH) thereof.

Note that any information that can be claimed confidential should be included in the subsequent field 'Confidential details on test material'.

Explanations:

- Name of test material (as cited in study report): only if different from any other identifiers provided in the preceding fields.

- Molecular formula (if other than submission substance): specify

- Molecular weight (if other than submission substance): specify

- Smiles notation (if other than submission substance): provide if available

- InChl (if other than submission substance): provide if available

- Structural formula attached as image file (if other than submission substance): see Fig.: only if different from submission substance. Indicate Fig. no. if a file is attached in field 'Attached document', e.g. state 'see Fig. 1'.

- Substance type: indicate whether pure active substance, technical product, formulation or other.

- Physical state: indicate 'gas', 'solid' or 'liquid' only if different from submission substance or if substance can occur in different physical states.

- Analytical purity: specify in %

- Impurities (identity and concentrations): specify

- Composition of the test material, percentage of components: specify if applicable

- Isomers composition: specify if applicable

- Purity test date: provide if available

- Lot/batch No.: provide if available

- Expiration date of the lot/batch: provide if available

- Radiochemical purity (if radiolabelling): specify if applicable

- Specific activity (if radiolabelling): specify if applicable

- Locations of the label (if radiolabelling): specify if applicable

- Expiration date of radiochemical substance (if radiolabelling): specify if applicable

- Storage condition of test substance: specify if applicable

- Stability under test conditions: indicate if available

Details on description and specification of the actual test material.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:TESTMAT_DETAILS>

<i5:set>

<i5:FREETEXT_BELOW>

<i5:FREETEXT_BELOW>

SE05.01.01.0440

Confidential details on test material

[Confidential details on test material]

  1. TEXT-TEMPL
  2. STRING/32768
  3. [N/A]
  4. 1
  5. 3
  6. [N/A]

Freetext Templates:

- Analytical purity:

- Impurities (identity and concentrations):

- Composition of test material, percentage of components:

- Purity test date:

- Lot/batch No.:

- Expiration date of the lot/batch:

- Isomers composition:

- Other:

Enter any confidential information on the test material in this separate field. Use freetext template and delete/add elements as appropriate. Enter any details that could be relevant for evaluating this study summary or that are requested by the respective regulatory programme. Consult the programme-specific guidance (e.g. OECD HPVC, Pesticides NAFTA or EU REACH) thereof.

Explanations:

- Analytical purity: specify in %

- Impurities (identity and concentrations): specify

- Composition of the test material, percentage of components: specify if applicable

- Purity test date: provide if available

- Lot/batch No.: : provide if available

- Expiration date of the lot/batch: : provide if available

- Isomers composition: specify if applicable

Confidential details on the actual test material.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:TESTMAT_CONFIDENTIAL_DETAILS>

<i5:set>

<i5:FREETEXT_BELOW>

<i5:FREETEXT_BELOW>

SE05.01.01.0450

Details on properties of test surrogate or analogue material

[Details on properties of test surrogate or analogue material]

  1. TEXT-TEMPL
  2. STRING/32768
  3. [N/A]
  4. 1
  5. 2
  6. [N/A]

Freetext Templates:

PHYSICO-CHEMICAL PROPERTIES

- Vapour pressure:

- Henry's Law constant:

- log Pow:

- pKa:

- UV absorption:

- Stability of test material at room temperature:

OTHER PROPERTIES (if relevant for this endpoint)

ONLY if another substance, i.e. analogue or surrogate (e.g. degradation/transformation product) was used as test material, enter any relevant details on the properties of this substance that may possibly affect the test performance, particularly physico-chemical properties.

Use freetext template and delete/add elements as appropriate.

Note that the physico-chemical properties of the substance for which the submission is made should be recorded in the corresponding templates and therefore need not be repeated here. Nevertheless, the possible influence of any physico-chemical properties should be indicated / discussed in appropriate fields, particularly in fields 'Details on test conditions' and 'Test performance'. This holds also true if any property of the substance is different in the test medium as compared to the data recorded in the section on physico-chemical properties.

Details on properties of test material, particularly physico-chemical properties. Relevant if an analogue or surrogate was used.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:PROPERTIES_TESTMAT_DETAILS>

<i5:set>

<i5:FREETEXT_BELOW>

<i5:FREETEXT_BELOW>

SE05.01.01.0455

Study design

[Study design]

  1. HEAD-2
  2. Heading level 2
  3. [N/A]
  4. 1
  5. 1
  6. [N/A]

 

 

Subheading of section 'Study design'

 

SE05.01.01.0460

Details on estimation method (if used)

[Estimation method (if used)]

  1. TEXT-TEMPL
  2. STRING/32768
  3. [N/A]
  4. 1
  5. 2
  6. [N/A]

Freetext Templates:

PHOTOCHEMICAL REACTION WITH OH RADICALS

- Concentration of OH radicals:

- Degradation rate constant:

- Temperature for which rate constant was calculated:

- Computer programme:

- Other:

OTHER ESTIMATION METHOD:

If the photodegradation was estimated, e.g. the photochemical reaction with OH radicals, include details on the computational method used. Use freetext template as appropriate. As an alternative option, attach a document e.g. excerpt from the study report.

Record the estimated half-life under 'Dissipation half-life of parent compound' in the Results section.

Guidance on freetext template:

- Concentration of OH radicals: e.g. '50000 molecules/cm³'

- Degradation rate constant: e.g. '18.3 x 10E-12 cm³/(molecule*sec)'

- Temperature for which rate constant was calculated: e.g. '25 °C'

- Computer programme: e.g. 'EPIWIN, part AOPWIN v.1.90. (2000)' or 'AOP based on SAR methods developed by Atkinson'

Details on parameters used to estimate photodegradation.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:ESTIMATION_METHOD>

<i5:set>

<i5:FREETEXT_BELOW>

<i5:FREETEXT_BELOW>

SE05.01.01.0470

Light source

[Light source]

  1. LIST-OPEN
  2. STRING/255
  3. [N/A]
  4. 1
  5. 1
  6. F03

Picklist Values:

sunlight || Xenon lamp || other: || no data

Select light source used.

Indicator specifying what light source was used, i.e. sun light or Xenon lamp.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:LIGHT_SOURCE>

<i5:set>

<i5:PHRASEOTHER_LIST_POP>

<i5:LIST_POP>

SE05.01.01.0471

Light source

[no label]

  1. OTHERTEXT
  2. STRING/255
  3. [N/A]
  4. 1
  5. 1
  6. [N/A]

 

 

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:LIGHT_SOURCE>

<i5:set>

<i5:PHRASEOTHER_LIST_POP>

<i5:LIST_POP_TXT>

SE05.01.01.0480

Light spectrum: wavelength in nm

[Light spectrum: wavelength in nm]

  1. LIST-CLOSED
  2. STRING/255
  3. [N/A]
  4. 1
  5. 1
  6. A02-1

Picklist Values:

> || >= || ca.

Include wavelength (in nm) range of the indicated light source. Not applicable if light source is sunlight.

Enter a numeric value or a range of numeric values according to following conventions:

(i) In the first numeric field, enter a single value (Qualifier subfield left blank) or a value if preceded by '>', '>=' or 'ca.' (e.g. '20', 'ca. 20', '>20').

(ii) In the second numeric field, enter a single value if preceded by '<' or '<='.

(iii) Use both numeric fields and, as required, the lower and upper qualifier field to enter a range of numeric values (e.g. '2 - 8' or '>2 <8').

Wavelength (in nm) of the indicated light source: Lower qualifier field providing a list with following operators: >, >=, and ca.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:LIGHTSPECTRUM>

<i5:set>

<i5:PRECISION_LOQUALIFIER>

<i5:LOQUALIFIER>

SE05.01.01.0490

Light spectrum: wavelength in nm

[no label]

  1. NUM
  2. NUMBER/20/########0.#########
  3. [N/A]
  4. 1
  5. 1
  6. [N/A]

 

 

Wavelength (in nm) of the indicated light source: Lower numeric field for entering a numeric value preceded either by no operator, '>', '>=' or 'ca.' (e.g. '20', '>20', '>=20', '20')

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:LIGHTSPECTRUM>

<i5:set>

<i5:PRECISION_LOQUALIFIER>

<i5:LOVALUE>

SE05.01.01.0500

Light spectrum: wavelength in nm

[no label]

  1. LIST-CLOSED
  2. STRING/255
  3. [N/A]
  4. 1
  5. 1
  6. A02-2

Picklist Values:

< || <= || ca.

 

Wavelength (in nm) of the indicated light source: Upper qualifier field providing a list with following operators: <, <=, and ca.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:LIGHTSPECTRUM>

<i5:set>

<i5:PRECISION_LOQUALIFIER>

<i5:UPQUALIFIER>

SE05.01.01.0510

Light spectrum: wavelength in nm

[no label]

  1. NUM
  2. NUMBER/20/########0.#########
  3. [N/A]
  4. 1
  5. 1
  6. [N/A]

 

 

Wavelength (in nm) of the indicated light source: Upper numeric field for entering a numeric value only if either a lower value is already entered to specify a numeric range or if the numeric value is preceded by either operator '<' or '<='.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:LIGHTSPECTRUM>

<i5:set>

<i5:PRECISION_LOQUALIFIER>

<i5:UPVALUE>

SE05.01.01.0520

Relative light intensity

[Relative light intensity]

  1. LIST-CLOSED
  2. STRING/255
  3. [N/A]
  4. 1
  5. 1
  6. A02-1

Picklist Values:

> || >= || ca.

Include the relative intensity of light based on sunlight or its range as appropriate.

Enter a numeric value or a range of numeric values according to following conventions:

(i) In the first numeric field, enter a single value (Qualifier subfield left blank) or a value if preceded by '>', '>=' or 'ca.' (e.g. '20', 'ca. 20', '>20').

(ii) In the second numeric field, enter a single value if preceded by '<' or '<='.

(iii) Use both numeric fields and, as required, the lower and upper qualifier field to enter a range of numeric values (e.g. '2 - 8' or '>2 <8').

Relative intensity of light based on sunlight: Lower qualifier field providing a list with following operators: >, >=, and ca.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:LIGHTINTENSITY>

<i5:set>

<i5:PRECISION_LOQUALIFIER>

<i5:LOQUALIFIER>

SE05.01.01.0530

Relative light intensity

[no label]

  1. NUM
  2. NUMBER/20/########0.#########
  3. [N/A]
  4. 1
  5. 1
  6. [N/A]

 

 

Relative intensity of light based on sunlight: Lower numeric field for entering a numeric value preceded either by no operator, '>', '>=' or 'ca.' (e.g. '20', '>20', '>=20', '20')

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:LIGHTINTENSITY>

<i5:set>

<i5:PRECISION_LOQUALIFIER>

<i5:LOVALUE>

SE05.01.01.0540

Relative light intensity

[no label]

  1. LIST-CLOSED
  2. STRING/255
  3. [N/A]
  4. 1
  5. 1
  6. A02-2

Picklist Values:

< || <= || ca.

 

Relative intensity of light based on sunlight: Upper qualifier field providing a list with following operators: <, <=, and ca.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:LIGHTINTENSITY>

<i5:set>

<i5:PRECISION_LOQUALIFIER>

<i5:UPQUALIFIER>

SE05.01.01.0550

Relative light intensity

[no label]

  1. NUM
  2. NUMBER/20/########0.#########
  3. [N/A]
  4. 1
  5. 1
  6. [N/A]

 

 

Relative intensity of light based on sunlight: Upper numeric field for entering a numeric value only if either a lower value is already entered to specify a numeric range or if the numeric value is preceded by either operator '<' or '<='.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:LIGHTINTENSITY>

<i5:set>

<i5:PRECISION_LOQUALIFIER>

<i5:UPVALUE>

SE05.01.01.0560

Details on light source

[Details on light source]

  1. TEXT-TEMPL
  2. STRING/32768
  3. [N/A]
  4. 1
  5. 2
  6. [N/A]

Freetext Templates:

- Emission wavelength spectrum:

- Filters used and their purpose:

- Light intensity at sample and area irradiated:

- Relative light intensity based on intensity of sunlight:

- Duration of light/darkness:

- Other:- Location:

- Latitude:

- Longitude:

- Hours of daylight:

- Time of year/month:

- Light intensity:

- Duration of light/darkness:

- Other:

Enter any relevant details on the light source. Use either of the two freetext templates as appropriate. As an alternative option, attach a document e.g. excerpt from the study report.

Further details on light source.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:LIGHT_SOURCE_DETAILS>

<i5:set>

<i5:FREETEXT_BELOW>

<i5:FREETEXT_BELOW>

SE05.01.01.0570

Details on test conditions

[Details on test conditions]

  1. TEXTAREA
  2. STRING/32768
  3. [N/A]
  4. 1
  5. 2
  6. [N/A]

 

Briefly describe the experimental set-up and procedure used.

Further details on test conditions.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:TESTCONDIT_DETAILS>

<i5:set>

<i5:TEXTAREA_BELOW>

<i5:TEXTAREA_BELOW>

SE05.01.01.0579

Duration of test at given test condition

[Duration of test at given test condition]

  1. HEAD BLOCK
  2. Block label
  3. g161
  4. 10
  5. 1
  6. [N/A]

 

Indicate the test duration, temperature and initial test substance concentration at which test was conducted. If test runs with different conditions and durations were performed, copy this block of fields as appropriate.

Heading of field block 'Duration of test at given temperature an initial concentration of test substance'.

 

SE05.01.01.0580

Duration

[Duration]

  1. NUM
  2. NUMBER/20/########0.#########
  3. g161
  4. 1
  5. 1
  6. [N/A]

 

Enter numeric value.

Numeric value of duration of test.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:DURATION>

<i5:set>

<i5:VALUEUNIT_VALUE>

<i5:VALUE>

SE05.01.01.0590

Unit

[Duration of test at given test condition]

  1. LIST-CLOSED
  2. STRING/255
  3. g161
  4. 1
  5. 1
  6. F05

Picklist Values:

min || h || d || wk || mo || yr

Select from drop-down list.

Unit of test duration.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:DURATION>

<i5:set>

<i5:VALUEUNIT_VALUE>

<i5:UNIT>

SE05.01.01.0600

Temperature

[Temp.]

  1. NUM
  2. NUMBER/20/########0.#########
  3. g161
  4. 1
  5. 1
  6. [N/A]

 

Enter numeric value.

Numeric value of temperature to which the duration given applies.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:DURATION>

<i5:set>

<i5:VALUEUNIT_TEMP_VALUE>

<i5:TEMP_VALUE>

SE05.01.01.0610

Unit

[Duration of test at given test condition]

  1. LIST-CLOSED
  2. STRING/255
  3. g161
  4. 1
  5. 1
  6. A102

Picklist Values:

°C || K || °F

Select from drop-down list.

Unit of temperature.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:DURATION>

<i5:set>

<i5:VALUEUNIT_TEMP_VALUE>

<i5:TEMP_UNIT>

SE05.01.01.0620

Initial measured concentration

[Initial conc. measured]

  1. NUM
  2. NUMBER/20/########0.#########
  3. g161
  4. 1
  5. 1
  6. [N/A]

 

Enter numeric value.

Numeric value of initial test substance concentration.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:DURATION>

<i5:set>

<i5:VALUEUNIT_INITIAL_CONC_VALUE>

<i5:INITIAL_CONC_VALUE>

SE05.01.01.0630

Unit

[Duration of test at given test condition]

  1. LIST-OPEN
  2. STRING/255
  3. g161
  4. 1
  5. 1
  6. F04

Picklist Values:

g/L || mg/L || mmol/L || mol/L || other:

Select from drop-down list.

Unit of initial test substance concentration.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:DURATION>

<i5:set>

<i5:VALUEUNIT_INITIAL_CONC_VALUE>

<i5:INITIAL_CONC_UNIT>

SE05.01.01.0631

Unit

[no label]

  1. OTHERTEXT
  2. STRING/255
  3. g161
  4. 1
  5. 1
  6. [N/A]

 

 

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:DURATION>

<i5:set>

<i5:VALUEUNIT_INITIAL_CONC_VALUE>

<i5:INITIAL_CONC_UNIT_TXT>

SE05.01.01.0640

Reference substance

[Reference substance]

  1. LIST-CLOSED-SUP
  2. STRING/255
  3. [N/A]
  4. 1
  5. 2
  6. A03

Picklist Values:

yes || no || no data

Indicate if test(s) with a substance with known photolysis was performed. If yes, report the identity of the substance in the supplementary remarks field.

Indication if reference substance(s) was/were tested.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:REFERENCE_SUBSTANCE>

<i5:set>

<i5:PHRASEOTHER_LIST_SEL_FIX>

<i5:LIST_SEL_FIX>

SE05.01.01.0641

Reference substance

[no label]

  1. SUP-TEXT
  2. STRING/255
  3. [N/A]
  4. 1
  5. 2
  6. [N/A]

 

 

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:REFERENCE_SUBSTANCE>

<i5:set>

<i5:PHRASEOTHER_LIST_SEL_FIX>

<i5:LIST_SEL_FIX_TXT>

SE05.01.01.0650

Any other information on materials and methods incl. tables

[Any other information on materials and methods incl. tables]

  1. RICHTEXT
  2. STRING/256000
  3. [N/A]
  4. 1
  5. 1
  6. [N/A]

 

In this field, you can enter any information on materials and methods, for which no distinct field is available, or transfer free text from other databases. You can also open a rich text editor and create formatted text and tables or insert and edit any excerpt from a word processing or spreadsheet document, provided it was converted to the HTML format.

Note: One rich text editor field each is provided for the MATERIALS AND METHODS and RESULTS section. In addition the fields 'Overall remarks' and 'Executive summary' allow rich text entry.

Rich text editor field for creating formatted text and tables or inserting and editing any excerpt from a word processing or spreadsheet document, provided it was converted to the HTML format.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:REM_ME_TC>

<i5:set>

<i5:RICHTEXT_BELOW>

<i5:RICHTEXT_BELOW>

SE05.01.01.0655

RESULTS AND DISCUSSION

[Results and discussions]

  1. HEAD-1
  2. Heading level 1
  3. [N/A]
  4. 1
  5. 1
  6. [N/A]

 

 

Main heading under which generic 'Results and discussion' fields are subsumed.

 

SE05.01.01.0660

Preliminary study

[Preliminary study]

  1. TEXTAREA
  2. STRING/2000
  3. [N/A]
  4. 1
  5. 2
  6. [N/A]

 

Describe results from preliminary study performed, if any (e.g., adsorption of test material to the walls of the test container).

Results from preliminary study performed, if any

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:PRELIM_STUDY_RS>

<i5:set>

<i5:TEXT_INT>

<i5:TEXT_INT>

SE05.01.01.0670

Test performance

[Test performance - Remarks]

  1. TEXTAREA
  2. STRING/2000
  3. [N/A]
  4. 1
  5. 2
  6. [N/A]

 

Report on any unusual observations during test, deviations from test procedure or any other information affecting results.

Description of any unusual observations during test, deviations from test procedure or any other information affecting results.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:TEST_PERFORM_REM>

<i5:set>

<i5:TEXT_INT>

<i5:TEXT_INT>

SE05.01.01.0679

Spectrum of substance

[Spectrum of substance]

  1. HEAD BLOCK
  2. Block label
  3. g162
  4. 10
  5. 1
  6. [N/A]

 

Select spectral parameter from picklist and enter value in the subsequent subfield. Any notes can be included in subfield 'Remarks'. Repeat field for each parameter cited in the study report.

If the substance absorbs light at wavelengths >295 nm, give the wavelength (lambda value) of maximum absorption at wavelengths >295 nm and the maximum molar absorption (extinction) coefficient (epsilon value). If there is no absorption maximum at >295 nm, give the molar extinction coefficient at 295 nm. An alternative to the above is to attach a file that depicts graphically or in tabular form the complete UV/VIS absorption spectrum (include reference to respective Figure or Table No. in subfield 'Remarks').

Heading of field block 'Spectrum of substance'

 

SE05.01.01.0680

Parameter

[Parameter]

  1. LIST-OPEN
  2. STRING/255
  3. g162
  4. 1
  5. 1
  6. F112

Picklist Values:

max lambda || max epsilon || epsilon 295 nm || other: || not applicable || no data

Select parameter from drop-down list and enter the corresponding value or range with unit (unless dimensionless) in the related text field, together with any explanation if necessary, e.g. on the study group the result refers to.

Explanations:

AUC: Area under the plasma (blood) level vs. time curve from zero up to a certain measured time point (specify the time);

Cmax: Maximum (peak) concentration;

C(time): Maximum concentration at a specified time after administration of a given dose;

Tmax: Time to reach peak or maximum concentration following administration

Indication of spectral parameter measured, i.e. lambda (max) (max. absorbance), epsilon (max) and epsilon (295 nm) (molar extinction coefficients).

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:SPECTRUM>

<i5:set>

<i5:PHRASEOTHER_PARAMETER>

<i5:PARAMETER>

SE05.01.01.0681

Parameter

[no label]

  1. OTHERTEXT
  2. STRING/255
  3. g162
  4. 1
  5. 1
  6. [N/A]

 

 

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:SPECTRUM>

<i5:set>

<i5:PHRASEOTHER_PARAMETER>

<i5:PARAMETER_TXT>

SE05.01.01.0690

Value

[Value]

  1. NUM
  2. NUMBER/20/########0.#########
  3. g162
  4. 1
  5. 1
  6. [N/A]

 

Enter numeric value.

Numeric value of the spectral parameter indicated in preceding subfield.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:SPECTRUM>

<i5:set>

<i5:VALUEUNIT_VALUE>

<i5:VALUE>

SE05.01.01.0700

Unit of spectral parameter

[Spectrum of substance]

  1. LIST-OPEN
  2. STRING/255
  3. g162
  4. 1
  5. 1
  6. P116

Picklist Values:

nm || m || L/(mol cm) || m²/mol || 1/cm dm³ 1/mol || other:

Select unit from drop-down list depending on the spectral parameter selected. E.g. use 'nm' for 'max lambda' or 'L/(mol cm)' or other appropriate unit for 'max epsilon'. If the unit is not listed, select 'other:' and specify.

Unit of spectral parameter.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:SPECTRUM>

<i5:set>

<i5:VALUEUNIT_VALUE>

<i5:UNIT>

SE05.01.01.0701

Unit of spectral parameter

[no label]

  1. OTHERTEXT
  2. STRING/255
  3. g162
  4. 1
  5. 1
  6. [N/A]

 

 

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:SPECTRUM>

<i5:set>

<i5:VALUEUNIT_VALUE>

<i5:UNIT_TXT>

SE05.01.01.0710

Remarks

[Remarks]

  1. TEXT
  2. STRING/255
  3. g162
  4. 1
  5. 1
  6. [N/A]

 

Enter any remarks related to the recorded value as appropriate.

Remarks on spectral parameter.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:SPECTRUM>

<i5:set>

<i5:REM>

<i5:REM>

SE05.01.01.0719

% Degradation of test substance

[% Degradation of test substance]

  1. HEAD BLOCK
  2. Block label
  3. g163
  4. 10
  5. 1
  6. [N/A]

 

Specify percentage of degradation or range and sampling time. Copy this block of fields for recording results at different test conditions.

Heading of field block '% Degradation of test substance'.

 

SE05.01.01.0720

% degradation

[%Degr.]

  1. LIST-CLOSED
  2. STRING/255
  3. g163
  4. 1
  5. 1
  6. A02-1

Picklist Values:

> || >= || ca.

Enter a numeric value or a range of numeric values according to following conventions:

(i) In the first numeric field, enter a single value (Qualifier subfield left blank) or a value if preceded by '>', '>=' or 'ca.' (e.g. '20', 'ca. 20', '>20').

(ii) In the second numeric field, enter a single value if preceded by '<' or '<='.

(iii) Use both numeric fields and, as required, the lower and upper qualifier field to enter a range of numeric values (e.g. '2 - 8' or '>2 <8').

Percentage of degradation of test substance: Lower qualifier field providing a list with following operators: >, >=, and ca.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:DEGRAD>

<i5:set>

<i5:PRECISION_LOQUALIFIER>

<i5:LOQUALIFIER>

SE05.01.01.0730

% degradation

[no label]

  1. NUM
  2. NUMBER/20/########0.#########
  3. g163
  4. 1
  5. 1
  6. [N/A]

 

 

Percentage of degradation of test substance: Lower numeric field for entering a numeric value preceded either by no operator, '>', '>=' or 'ca.' (e.g. '20', '>20', '>=20', '20')

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:DEGRAD>

<i5:set>

<i5:PRECISION_LOQUALIFIER>

<i5:LOVALUE>

SE05.01.01.0740

% degradation

[no label]

  1. LIST-CLOSED
  2. STRING/255
  3. g163
  4. 1
  5. 1
  6. A02-2

Picklist Values:

< || <= || ca.

 

Percentage of degradation of test substance: Upper qualifier field providing a list with following operators: <, <=, and ca.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:DEGRAD>

<i5:set>

<i5:PRECISION_LOQUALIFIER>

<i5:UPQUALIFIER>

SE05.01.01.0750

% degradation

[no label]

  1. NUM
  2. NUMBER/20/########0.#########
  3. g163
  4. 1
  5. 1
  6. [N/A]

 

 

Percentage of degradation of test substance: Upper numeric field for entering a numeric value only if either a lower value is already entered to specify a numeric range or if the numeric value is preceded by either operator '<' or '<='.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:DEGRAD>

<i5:set>

<i5:PRECISION_LOQUALIFIER>

<i5:UPVALUE>

SE05.01.01.0760

St. dev.

[St. dev.]

  1. NUM
  2. NUMBER/20/########0.#########
  3. g163
  4. 1
  5. 1
  6. [N/A]

 

Enter numeric value.

Standard deviation of percentage of degradation of test substance.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:DEGRAD>

<i5:set>

<i5:STDEV>

<i5:STDEV>

SE05.01.01.0770

Sampling time

[Sampling time]

  1. NUM
  2. NUMBER/20/########0.#########
  3. g163
  4. 1
  5. 1
  6. [N/A]

 

Enter numeric value.

Sampling time

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:DEGRAD>

<i5:set>

<i5:VALUEUNIT_TIMEPOINT_VALUE>

<i5:TIMEPOINT_VALUE>

SE05.01.01.0780

Unit sampling time

[% Degradation of test substance]

  1. LIST-CLOSED
  2. STRING/255
  3. g163
  4. 1
  5. 1
  6. F05

Picklist Values:

min || h || d || wk || mo || yr

Select from drop-down list.

Unit of time.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:DEGRAD>

<i5:set>

<i5:VALUEUNIT_TIMEPOINT_VALUE>

<i5:TIMEPOINT_UNIT>

SE05.01.01.0790

Test condition

[Test condition]

  1. TEXT
  2. STRING/255
  3. g163
  4. 1
  5. 1
  6. [N/A]

 

If results at different test conditions are reported, specify test condition (e.g. different temperatures). Otherwise leave this subfield empty.

Brief description of test run if results are given for different test runs.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:DEGRAD>

<i5:set>

<i5:TEST_CONDITION>

<i5:TEST_CONDITION>

SE05.01.01.0800

Quantum yield (for direct photolysis)

[Quantum yield (for direct photolysis)]

  1. NUM
  2. NUMBER/19/########0.#########
  3. [N/A]
  4. 1
  5. 1
  6. [N/A]

 

Give the reaction quantum yield of the test substance (values between 0 and 1).

The reaction efficiency as calculated from the experimental measurements derived from a direct photolysis study.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:QUANTUM_YIELD>

<i5:set>

<i5:NUMBER_POS_BELOW>

<i5:NUMBER_POS_BELOW>

SE05.01.01.0809

Dissipation half-life of parent compound

[Dissipation half-life of parent compound]

  1. HEAD BLOCK
  2. Block label
  3. g164
  4. 10
  5. 1
  6. [N/A]

 

Provide the half-life / DT50 or range as appropriate. Copy this block of fields for recording results at different test conditions.

Heading of field block 'Kinetics and dissipation half-life of parent compound'

 

SE05.01.01.0810

Half-life / DT50

[DT50]

  1. LIST-CLOSED
  2. STRING/255
  3. g164
  4. 1
  5. 1
  6. A02-1

Picklist Values:

> || >= || ca.

Enter a numeric value or a range of numeric values according to following conventions:

(i) In the first numeric field, enter a single value (Qualifier subfield left blank) or a value if preceded by '>', '>=' or 'ca.' (e.g. '20', 'ca. 20', '>20').

(ii) In the second numeric field, enter a single value if preceded by '<' or '<='.

(iii) Use both numeric fields and, as required, the lower and upper qualifier field to enter a range of numeric values (e.g. '2 - 8' or '>2 <8').

First order/other half life: Lower qualifier field providing a list with following operators: >, >=, and ca.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:DISSIP>

<i5:set>

<i5:PRECISION_HALFLIFE_LOQUALIFIER>

<i5:HALFLIFE_LOQUALIFIER>

SE05.01.01.0820

Half-life / DT50

[no label]

  1. NUM
  2. NUMBER/20/########0.#########
  3. g164
  4. 1
  5. 1
  6. [N/A]

 

 

First order/other half life: Lower numeric field for entering a numeric value preceded either by no operator, '>', '>=' or 'ca.' (e.g. '20', '>20', '>=20', '20')

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:DISSIP>

<i5:set>

<i5:PRECISION_HALFLIFE_LOQUALIFIER>

<i5:HALFLIFE_LOVALUE>

SE05.01.01.0830

Half-life / DT50

[no label]

  1. LIST-CLOSED
  2. STRING/255
  3. g164
  4. 1
  5. 1
  6. A02-2

Picklist Values:

< || <= || ca.

 

First order/other half life: Upper qualifier field providing a list with following operators: <, <=, and ca.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:DISSIP>

<i5:set>

<i5:PRECISION_HALFLIFE_LOQUALIFIER>

<i5:HALFLIFE_UPQUALIFIER>

SE05.01.01.0840

Half-life / DT50

[no label]

  1. NUM
  2. NUMBER/20/########0.#########
  3. g164
  4. 1
  5. 1
  6. [N/A]

 

 

First order/other half life: Upper numeric field for entering a numeric value only if either a lower value is already entered to specify a numeric range or if the numeric value is preceded by either operator '<' or '<='.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:DISSIP>

<i5:set>

<i5:PRECISION_HALFLIFE_LOQUALIFIER>

<i5:HALFLIFE_UPVALUE>

SE05.01.01.0850

Unit

[Dissipation half-life of parent compound]

  1. LIST-CLOSED
  2. STRING/255
  3. g164
  4. 1
  5. 1
  6. F05

Picklist Values:

min || h || d || wk || mo || yr

Select from drop-down list.

Unit of half life.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:DISSIP>

<i5:set>

<i5:PRECISION_HALFLIFE_LOQUALIFIER>

<i5:HALFLIFE_UNIT>

SE05.01.01.0860

Test condition

[Test condition]

  1. TEXT
  2. STRING/255
  3. g164
  4. 1
  5. 1
  6. [N/A]

 

If results at different test conditions are reported, specify test condition (e.g. different temperatures). Otherwise leave this subfield empty.

Brief description of test condition if results are given for different test runs.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:DISSIP>

<i5:set>

<i5:TEST_CONDITION>

<i5:TEST_CONDITION>

SE05.01.01.0861

Degradation rate constant

[Degradation rate constant]

  1. HEAD BLOCK
  2. Block label
  3. g165
  4. 5
  5. 1
  6. [N/A]

 

If provided, specify the rate constant for the reaction with OH radicals and/or ozone.

 

SE05.01.01.0862

Reaction with

[Reaction with]

  1. LIST-OPEN
  2. STRING/255
  3. g165
  4. 1
  5. 1
  6. TD320

Picklist Values:

OH radicals || ozone || other:

Select the type of molecule the substance reacts with from drop-down list, i.e. OH or ozone or select 'other:' and specify.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:RATE_CONSTANT>

<i5:set>

<i5:PHRASEOTHER_TYPE>

<i5:TYPE>

SE05.01.01.0863

Reaction with

[no label]

  1. OTHERTEXT
  2. STRING/255
  3. g165
  4. 1
  5. 1
  6. [N/A]

 

 

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:RATE_CONSTANT>

<i5:set>

<i5:PHRASEOTHER_TYPE>

<i5:TYPE_TXT>

SE05.01.01.0864

Rate constant

[Rate constant]

  1. LIST-CLOSED
  2. STRING/255
  3. g165
  4. 1
  5. 1
  6. A02-1

Picklist Values:

> || >= || ca.

Enter a numeric value or a range of numeric values according to following conventions:

(i) In the first numeric field, enter a single value (Qualifier subfield left blank) or a value if preceded by '>', '>=' or 'ca.' (e.g. '20', 'ca. 20', '>20').

(ii) In the second numeric field, enter a single value if preceded by '<' or '<='.

(iii) Use both numeric fields and, as required, the lower and upper qualifier field to enter a range of numeric values (e.g. '2 - 8' or '>2 <8').

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:RATE_CONSTANT>

<i5:set>

<i5:PRECISION_RATE_LOQUALIFIER>

<i5:RATE_LOQUALIFIER>

SE05.01.01.0865

Rate constant

[no label]

  1. NUM
  2. NUMBER/20/########0.#########
  3. g165
  4. 1
  5. 1
  6. [N/A]

 

 

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:RATE_CONSTANT>

<i5:set>

<i5:PRECISION_RATE_LOQUALIFIER>

<i5:RATE_LOVALUE>

SE05.01.01.0866

Rate constant

[no label]

  1. LIST-CLOSED
  2. STRING/255
  3. g165
  4. 1
  5. 1
  6. A02-2

Picklist Values:

< || <= || ca.

 

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:RATE_CONSTANT>

<i5:set>

<i5:PRECISION_RATE_LOQUALIFIER>

<i5:RATE_UPQUALIFIER>

SE05.01.01.0867

Rate constant

[no label]

  1. NUM
  2. NUMBER/20/########0.#########
  3. g165
  4. 1
  5. 1
  6. [N/A]

 

 

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:RATE_CONSTANT>

<i5:set>

<i5:PRECISION_RATE_LOQUALIFIER>

<i5:RATE_UPVALUE>

SE05.01.01.0868

Unit

[Degradation rate constant]

  1. LIST-CLOSED
  2. STRING/255
  3. g165
  4. 1
  5. 1
  6. TD90

Picklist Values:

cm³ molecule-1 s-1 || cm³ molecule-1 d-1 || m³ molecule-1 s-1 || m³ molecule-1 d-1

Select from drop-down list.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:RATE_CONSTANT>

<i5:set>

<i5:PRECISION_RATE_LOQUALIFIER>

<i5:RATE_UNIT>

SE05.01.01.0870

Transformation products

[Transformation products]

  1. LIST-CLOSED
  2. STRING/255
  3. [N/A]
  4. 1
  5. 1
  6. E34

Picklist Values:

no || not measured || yes || no data

Indicate whether transformation products occurred. If yes, provide the identified transformation products in following block of fields. Any further details can be entered in field 'Any other information on results incl. tables'.

Indicator that transformation products occurred or not.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:TRANSF_PRODUCTS_INDICATOR>

<i5:set>

<i5:LIST_BELOW_SEL>

<i5:LIST_BELOW_SEL>

SE05.01.01.0879

Identity of transformation products

[Identity of degradation products]

  1. HEAD BLOCK
  2. Block label
  3. g166
  4. 20
  5. 1
  6. [N/A]

 

Indicate the identity of the transformation products using an appropriate identifier, e.g. CAS number, CAS name, IUPAC name. Copy this block of fields for each relevant substance.

Any further details on transformation products can be provided in field 'Any other information on materials and methods incl. tables'.

Heading of field block 'Identity of degradation / transformation products'.

 

SE05.01.01.0880

No.

[No.]

  1. LIST-CLOSED
  2. STRING/255
  3. g166
  4. 1
  5. 1
  6. F137

Picklist Values:

#1 || #2 || #3 || #4 || #5 || #6 || #7 || #8 || #9 || #10 || #11 || #12 || #13 || #14 || #15 || #16 || #17 || #18 || #19 || #20

For easier distinction select a consecutive number for each transformation product from drop-down list if more than one transformation product is entered. If the same substance is identified by more than one identifiers (e.g. by CAS name and Common name), make sure that the same number is allocated to these entries.

Indication of a consecutive number 1-n used to distinguish the degradation / transformation products.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:TRANSF_PRODUCTS_ID>

<i5:set>

<i5:NO>

<i5:NO>

SE05.01.01.0890

Identifier

[Identifier]

  1. LIST-OPEN
  2. STRING/255
  3. g166
  4. 1
  5. 1
  6. Z39

Picklist Values:

CAS name || CAS number || Common name || EC name || EC number || IUPAC name || TSCA name || other:

Select an appropriate identifier from drop-down list, e.g. 'CAS number'. Use 'Other:' if identity according to a standard identifier is not known. Specify if another identifier is provided (e.g. 'Other: xxx').

Indicator specifying the type of chemical identifier, e.g. CAS name.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:TRANSF_PRODUCTS_ID>

<i5:set>

<i5:PHRASEOTHER_IDENTIFIER>

<i5:IDENTIFIER>

SE05.01.01.0891

Identifier

[no label]

  1. OTHERTEXT
  2. STRING/255
  3. g166
  4. 1
  5. 1
  6. [N/A]

 

 

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:TRANSF_PRODUCTS_ID>

<i5:set>

<i5:PHRASEOTHER_IDENTIFIER>

<i5:IDENTIFIER_TXT>

SE05.01.01.0900

Identity

[Identity]

  1. TEXT
  2. STRING/255
  3. g166
  4. 1
  5. 1
  6. [N/A]

 

Select the corresponding substance identity from drop-down list or enter manually if the identity is not available from the list or if no list is provided for the type of identifier selected.

Identity of the chemical substance.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:TRANSF_PRODUCTS_ID>

<i5:set>

<i5:ID>

<i5:ID>

SE05.01.01.0910

Results with reference substance

[Results with reference substance]

  1. TEXTAREA
  2. STRING/2000
  3. [N/A]
  4. 1
  5. 2
  6. [N/A]

 

Indicate whether the results with the reference substance(s) are valid.

Indication whether the results with the reference substance(s) are valid.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:RS_REF_SUBSTANCE>

<i5:set>

<i5:TEXT_INT>

<i5:TEXT_INT>

SE05.01.01.0920

Any other information on results incl. tables

[Any other information on results incl. tables]

  1. RICHTEXT
  2. STRING/256000
  3. [N/A]
  4. 1
  5. 1
  6. [N/A]

 

In this field, you can enter any other remarks on results. You can also open a rich text editor and create formatted text and tables or insert and edit any excerpt from a word processing or spreadsheet document, provided it was converted to the HTML format.

Note: Both the 'Materials and methods' section and 'Results' section. In addition the fields 'Overall remarks' and 'Executive summary' allow rich text entry.

Rich text editor field for creating formatted text and tables or inserting and editing any excerpt from a word processing or spreadsheet document, provided it was converted to the HTML format.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:REM_RS>

<i5:set>

<i5:RICHTEXT_BELOW>

<i5:RICHTEXT_BELOW>

SE05.01.01.0925

OVERALL REMARKS, ATTACHMENTS

[Overall remarks, attachments]

  1. HEAD-1
  2. Heading level 1
  3. [N/A]
  4. 1
  5. 1
  6. [N/A]

 

 

Main heading under which 'Overall remarks, attachments' fields are subsumed.

 

SE05.01.01.0930

Remarks on results including tables and figures

[Remarks on results including tables and figures]

  1. RICHTEXT
  2. STRING/256000
  3. [N/A]
  4. 1
  5. 1
  6. [N/A]

 

In this field, you can enter any overall remarks or transfer free text from other databases. You can also open a rich text editor and create formatted text and tables or insert and edit any excerpt from a word processing or spreadsheet document, provided it was converted to the HTML format.

Note: One rich text editor field each is provided for the MATERIALS AND METHODS and RESULTS section. In addition the fields 'Overall remarks' and 'Executive summary' allow rich text entry.

Rich text editor field for creating formatted text and tables or inserting and editing any excerpt from a word processing or spreadsheet document, provided it was converted to the HTML format.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:REM_ANYOTHER>

<i5:set>

<i5:RICHTEXT_BELOW>

<i5:RICHTEXT_BELOW>

SE05.01.01.0939

Attached background material

[Attached background material]

  1. HEAD BLOCK
  2. Block label
  3. g167
  4. 10
  5. 1
  6. [N/A]

 

Attach any background document that cannot be inserted in any rich text editor field, particularly image files (e.g. an image of a structural formula).

Copy this block of fields for attaching more than one file.

Heading of field block 'Attached document'.

 

SE05.01.01.0940

Attached document

[Attached document]

  1. ATTACHMENT
  2. STRING/32768
  3. g167
  4. 1
  5. 1
  6. [N/A]

 

Upload file by clicking the upload icon. As appropriate, enter any additional information, e.g. language. The file name is displayed after uploading the document.

File name of document uploaded, i.e. attached. No restriction as to file type.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:AD>

<i5:set>

<i5:DOC>

<i5:DOC>

SE05.01.01.0950

Remarks

[Remarks]

  1. TEXT
  2. STRING/255
  3. g167
  4. 1
  5. 1
  6. [N/A]

 

As appropriate, include remarks, e.g. a short description of the content of the attached document if the file name is not self-explanatory.

Remarks on attached document.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:AD>

<i5:set>

<i5:REM>

<i5:REM>

SE05.01.01.0959

Attached full study report

[Attached full study report]

  1. HEAD BLOCK
  2. Block label
  3. g168
  4. 10
  5. 1
  6. [N/A]

 

If required, an electronic copy of the full study report can be attached as WORD, pdf or other document type, which will not be integrated in any report, but must be handled as separate files.

Note: In the export administration you can indicate whether the attached files should be included in the data export or not.

Attached full study report

 

SE05.01.01.0960

Attached full study report

[Attached full study report]

  1. ATTACHMENT
  2. STRING/32768
  3. g168
  4. 1
  5. 1
  6. [N/A]

 

Upload file by clicking the upload icon. As appropriate, enter any additional information, e.g. language. The file name is displayed after uploading the document.

Attached full study report

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:AD_STUDYREPORT>

<i5:set>

<i5:ATTACHMENT_BELOW>

<i5:ATTACHMENT_BELOW>

SE05.01.01.0962

Illustration (picture/graph)

[Illustration (picture/graph)]

  1. PICTURE
  2. STRING/32768
  3. [N/A]
  4. 1
  5. 1
  6. [N/A]

 

Upload file by clicking the upload icon. As appropriate, enter any additional information, e.g. language. The file name is displayed after uploading the document.

Illustration (picture/graph)

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:PG_ILLUSTRATION>

<i5:set>

<i5:PIC_BELOW>

<i5:PIC_BELOW>

SE05.01.01.0965

APPLICANT'S SUMMARY AND CONCLUSION

[Applicant's summary and conclusion]

  1. HEAD-1
  2. Heading level 1
  3. [N/A]
  4. 1
  5. 1
  6. [N/A]

 

 

Main heading under which generic 'Applicant's summary and conclusion' fields are subsumed.

 

SE05.01.01.0970

Validity criteria fulfilled

[Validity criteria fulfilled]

  1. LIST-CLOSED-SUP
  2. STRING/255
  3. [N/A]
  4. 1
  5. 1
  6. F102

Picklist Values:

yes || no || no data || not applicable

Indicate whether validity criteria given by test guideline have been fulfilled or not. Use supplementary remarks field for indicating the criteria and entering remarks. Clearly indicate if the criteria used are not consistent with those given by the test guideline. If so, give justification in field 'Rationale for reliability incl. deficiencies' as to why this study summary is considered reliable.

Indication of validity criteria and whether they have been fulfilled or not.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:VALIDITY_CRIT_SUBM>

<i5:set>

<i5:PHRASEOTHER_LIST_SEL_FIX>

<i5:LIST_SEL_FIX>

SE05.01.01.0971

Validity criteria fulfilled

[no label]

  1. SUP-TEXT
  2. STRING/255
  3. [N/A]
  4. 1
  5. 1
  6. [N/A]

 

 

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:VALIDITY_CRIT_SUBM>

<i5:set>

<i5:PHRASEOTHER_LIST_SEL_FIX>

<i5:LIST_SEL_FIX_TXT>

SE05.01.01.0980

Conclusions

[Conclusions]

  1. TEXTAREA
  2. STRING/32768
  3. [N/A]
  4. 1
  5. 1
  6. [N/A]

 

Enter any conclusions if applicable.

Any conclusions either as adapted from the study report / publication or indicated by the submitter.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:APPL_CL>

<i5:set>

<i5:TEXTAREA_BELOW>

<i5:TEXTAREA_BELOW>

SE05.01.01.0990

Executive summary

[Executive summary]

  1. RICHTEXT
  2. STRING/256000
  3. [N/A]
  4. 1
  5. 1
  6. [N/A]

 

If required by the respective national/regional programme, briefly summarise the relevant aspects of the study including the conclusions reached. If a specific format is prescribed, upload the respective freetext template if available from the drop-down list or copy it from the corresponding document.

Consult the programme-specific guidance (e.g. OECD HPVC, Pesticides NAFTA or EU REACH) thereof.

Executive summary in which the relevant aspects of the study including the conclusions reached are briefly summarised.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:APPL_EXEC_SUM>

<i5:set>

<i5:RICHTEXT_BELOW>

<i5:RICHTEXT_BELOW>

SE05.01.01.1000

Cross-reference to other study

[Cross-reference to other study]

  1. TEXTAREA
  2. STRING/2000
  3. [N/A]
  4. 1
  5. 1
  6. [N/A]

 

A Cross-reference to other study or other studies can be included which are considered relevant in the interpretation of the test results, e.g. for supporting the conclusion that an effect observed was not substance-related. Indicate the respective chapter(s) and record ID(s) and enter relevant explanatory text.

Such cross-references may be useful if it is considered relevant to discuss other results at the summary level of a single study. It should be noted that the overall appraisal of results from different studies is normally done in the hazard or risk assessment.

Note that any such cross-reference may become useless if a record is either printed or exchanged on its own.

A cross-reference to another study or other studies including explanatory text on why other results are relevant in the interpretation of the results of a given study, e.g. for supporting any conclusions.

<i5:EndpointStudyRecord>

<i5:scientificPart>

<i5:TO_PHOTOTRANS_AIR>

<i5:CROSSREF_OTHER_STUDY>

<i5:set>

<i5:TEXT_BELOW>

<i5:TEXT_BELOW>